Rotational limb alignment changes following total knee arthroplasty

被引:18
|
作者
Hauschild, Oliver [1 ]
Muenzberg, Matthias [2 ]
Knothe, Dagmar [3 ]
Konstantinidis, Lukas [1 ]
Helwig, Peter [1 ]
Sudkamp, Norbert P. [1 ]
Thielemann, Friedrich W. [4 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Orthoped & Trauma Surg, D-79106 Freiburg, Germany
[2] Heidelberg Univ, BG Trauma Ctr Ludwigshafen, Ludwigshafen, Germany
[3] Tuttlingen Hosp, Dept Diagnost Radiol, Tuttlingen, Germany
[4] Schwarzwald Baar Hosp, Dept Trauma Hand & Reconstruct Surg, Villingen Schwenningen, Germany
关键词
Rotational limb alignment; TKA; Component placement; Reproducibility; Computed tomography; OSTEOARTHRITIC KNEES; FEMORAL COMPONENT; TIBIAL COMPONENT; DISTAL FEMUR; MRI ANALYSIS; CT-SCAN; TOMOGRAPHY; TORSION; MALROTATION; ACCURACY;
D O I
10.1007/s00167-012-2322-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the present study was to assess the changes in rotational alignment introduced by total knee arthroplasty (TKA) and the reproducibility of pre- and postoperative CT measurements of rotational limb alignment. For this purpose we analyzed data from 196 consecutive cruciate-retaining, fixed bearing Columbus TKA procedures. Both pre- and postoperative scans torsion difference CT scans were available for measurements in 89 cases. Using these CT scans the neck-malleolar angle (NMA), the femoral posterior condylar angle (fPCA), the tibial posterior condylar axis (tPCA) and the tibial torsion angle (TTA) were independently assessed by three raters. CT scans were re-evaluated 8 weeks later by the most experienced rater for assessment of intraobserver agreement. Measurements of all angles were prone to high standard deviations reflecting interindividual variability. Mean fPCA changed from 1.3A degrees to 2.7A degrees internal rotation preoperatively to 0.1A degrees-1.9A degrees internal rotation postoperatively. Based on a relative external rotation of the tibial base plate as compared to the preoperative situation, we found a relative internal rotation of the postoperative NMA and tibial torsion of 3A degrees-5.4A degrees and 6A degrees-7.5A degrees, respectively. Intra- and interobserver agreement was strong for all angles assessed (ICCs 0.7-1.0) except for fPCA (ICC 0.2-0.6). However, mean absolute measurement differences for fPCA were clinically acceptable (1.2A degrees-2.6A degrees). Reproducibility of CT rotational limb alignment measurements was found to be clinically acceptable. Rotational alignment of the femoral and even more so of the tibial component will ultimately affect the rotational alignment of the entire limb-at least when fixed bearings are used. Diagnostic study, Level III.
引用
收藏
页码:2346 / 2354
页数:9
相关论文
共 50 条
  • [11] Changes in knee alignment after total knee arthroplasty
    Matsuda, S
    Miura, H
    Nagamine, R
    Urabe, K
    Harimaya, K
    Matsunobu, T
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 566 - 570
  • [12] Effect of rotational alignment on patellar tracking in total knee arthroplasty
    Akagi, M
    Matsusue, Y
    Mata, T
    Asada, Y
    Horiguchi, M
    Iida, H
    Nakamura, T
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (366) : 155 - 163
  • [13] Can rotational alignment of total knee arthroplasty be measured on MRI?
    Mirco Sgroi
    M. Faschingbauer
    K. Javaheripour-Otto
    H. Reichel
    T. Kappe
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1589 - 1594
  • [14] Navigation improves accuracy of rotational alignment in total knee arthroplasty
    Stöckl, B
    Nogler, M
    Rosiek, R
    Fischer, M
    Krismer, M
    Kessler, O
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 180 - 186
  • [15] Change in tibiofemoral rotational alignment during total knee arthroplasty
    Watanabe, Satoshi
    Sato, Takashi
    Omori, Go
    Koga, Yoshio
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (04) : 571 - 578
  • [16] Can rotational alignment of total knee arthroplasty be measured on MRI?
    Sgroi, Mirco
    Faschingbauer, M.
    Javaheripour-Otto, K.
    Reichel, H.
    Kappe, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (11) : 1589 - 1594
  • [17] The high variability of tibial rotational alignment in total knee arthroplasty
    Siston, Robert A.
    Goodman, Stuart B.
    Patel, Jay J.
    Delp, Scott L.
    Giori, Nicholas J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 65 - 69
  • [18] Changes in knee kinematics following total knee arthroplasty
    Shandiz, Mohsen Akbari
    Boulos, Paul
    Saevarsson, Stefan Karl
    Yoo, Sam
    Miller, Stephen
    Anglin, Carolyn
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (04) : 265 - 278
  • [19] Changes in patellar alignment after total knee arthroplasty
    Fukagawa, Shingo
    Matsuda, Shuichi
    Mizu-uchi, Hideki
    Miura, Hiromasa
    Okazaki, Ken
    Iwamoto, Yukihide
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (01) : 99 - 104
  • [20] Changes in patellar alignment after total knee arthroplasty
    Shingo Fukagawa
    Shuichi Matsuda
    Hideki Mizu-uchi
    Hiromasa Miura
    Ken Okazaki
    Yukihide Iwamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 99 - 104