Zero boil-off methods for large-scale liquid hydrogen tanks using integrated refrigeration and storage

被引:35
|
作者
Notardonato, W. U. [1 ]
Swanger, A. M. [1 ]
Fesmire, J. E. [1 ]
Jumper, K. M. [1 ]
Johnson, W. L. [2 ]
Tomsik, T. M. [2 ]
机构
[1] NASA Kennedy Space Ctr, Cryogen Test Lab, UB R1, Ksc, FL 32899 USA
[2] NASA Glenn Res Ctr, Cryogen & Fluids Branch, LTF 0, Cleveland, OH 44135 USA
来源
关键词
D O I
10.1088/1757-899X/278/1/012012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multilayer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Large scale demonstration of liquid hydrogen storage with zero boiloff
    Hedayat, A
    Hastings, LJ
    Bryant, C
    Plachta, DW
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 1276 - 1283
  • [22] Techno-economic analysis of large-scale CO2 ship transport with onboard boil-off gas reliquefaction
    Noh, Hyonjeong
    Kang, Kwangu
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2025, 142
  • [23] Thermodynamic optimization of composite insulation system with cold shield for liquid hydrogen zero-boil-off storage
    Zheng, Jianpeng
    Chen, Liubiao
    Liu, Xuming
    Zhu, Honglai
    Zhou, Yuan
    Wang, Junjie
    RENEWABLE ENERGY, 2020, 147 : 824 - 832
  • [24] Large-scale stationary hydrogen storage via liquid organic hydrogen carriers
    Abdin, Zainul
    Tang, Chunguang
    Liu, Yun
    Catchpole, Kylie
    ISCIENCE, 2021, 24 (09)
  • [25] Large-scale liquid hydrogen production methods and approaches: A review
    Aasadnia, Majid
    Mehrpooya, Mehdi
    APPLIED ENERGY, 2018, 212 : 57 - 83
  • [26] Simulation on a proposed large-scale liquid hydrogen plant using a multi-component refrigerant refrigeration system
    Krasae-in, Songwut
    Stang, Jacob H.
    Neksa, Petter
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (22) : 12531 - 12544
  • [27] Optimal operation of a large-scale liquid hydrogen plant utilizing mixed fluid refrigeration system
    Krasae-in, Songwut
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (13) : 7015 - 7029
  • [28] Large-scale underground hydrogen storage: Integrated modeling of reservoir-wellbore system
    Abdellatif, Mohab
    Hashemi, Mehrdad
    Azizmohammadi, Siroos
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (50) : 19160 - 19171
  • [29] Role of large-scale underground hydrogen storage and its pathways to achieve net-zero in China
    Chen, Yongqiang
    Jin, Xing
    Zeng, Lingping
    Zhong, Zhiqi
    Mehana, Mohamed
    Xiao, Wenlian
    Pu, Wanfen
    Regenauer-Lieb, Klaus
    Xie, Quan
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [30] A short discussion on insulation strategies and design considerations for large-scale storage and transportation of liquid hydrogen
    Ratnakar, Ram R.
    Sharma, Swapnil
    Taghavi, Mahsa
    Balakotaiah, Vemuri
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2023,