CURRENT HARMONIC DISTORTION IN OFFICE BUILDING ELECTRIC NETWORK

被引:0
|
作者
Albu, Horatiu [1 ]
Pop, Florin [1 ]
机构
[1] Tech Univ Cluj Napoca, Cluj Napoca, Romania
关键词
D O I
暂无
中图分类号
F [经济];
学科分类号
02 ;
摘要
This paper presents an analysis of the current harmonic distortion at the point of common coupling of an office building. At first the problem of the harmonic distortion of the current wave-shape is analysed for lighting systems and office equipments. Measurements are presented for each type of office load, with the purpose of emphasising the non-linear load characteristics. Next the problem of assessing the current harmonic distortion at the point of common coupling is analysed. A case study is presented, where the harmonic distortion of the current wave-shape is analysed for an office building, based on individual equipment measurements and 24-hour load operation profile. Two scenarios are discussed: with and without the implement of occupancy sensors in office rooms. It can be seen in both scenarios that the harmonic current distortions closely correlate with the fundamental current (power demand) of the office load. The use of occupancy sensors brings important energy savings, with the cost of slightly higher current harmonic distortion.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 50 条
  • [31] Harmonic Distortion in Switched Current Cells Due to Settling Error
    Miguel García-Andrade
    Guillermo Espinosa
    David Báez-López
    Analog Integrated Circuits and Signal Processing, 2004, 41 : 199 - 208
  • [32] Harmonic Distortion of Current Consumed by Frequency Converters at Low Loads
    N. S. Varlamov
    V. G. Sugakov
    O. S. Khvatov
    Yu. S. Malyshev
    Russian Electrical Engineering, 2024, 95 (10) : 838 - 843
  • [33] A Novel Approach to Current Transformer Characterization in the Presence of Harmonic Distortion
    Cataliotti, Antonio
    Di Cara, Dario
    Emanuel, Alexander E.
    Nuccio, Salvatore
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1446 - 1453
  • [34] Harmonic distortion on class AB CMOS current output stages
    Universita di Catania, Catania, Italy
    IEEE Trans Circuits Syst II Analog Digital Signal Process, 2 (243-250):
  • [35] Harmonic distortion in switched current cells due to settling error
    García, M
    Espinosa, G
    Báez-López, D
    ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, 2002, : 261 - 264
  • [36] Design of Filters in Matlab Simulink for Reducing Current Harmonic Distortion
    Singh, Dhiraj Kumar
    Soni, Rohit
    Mittal, Devendra
    2013 IEEE SECOND INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP), 2013, : 416 - 420
  • [37] Analysis of Operation of Synchronous Generator Under the Distortion of Harmonic Current
    Wang Jin-quan
    Song Peng-chao
    Cui Chen-hua
    Li Jian-ke
    Yang Tao
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [38] Harmonic distortion in switched-current audio memory cells
    Technical Univ of Lisbon, Lisbon, Portugal
    IEEE Trans Comput Aided Des Integr Circuits Syst, 4 (326-334):
  • [39] Estimation of the total current harmonic distortion using an ELF magnetometer
    Portillo, Francisco
    Alcayde, Alfredo
    Garcia, Rosa M.
    Novas, Nuria
    Gazquez, Jose Antonio
    Fernandez-Ros, Manuel
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 371
  • [40] Improving the Accuracy of Current Transformers through Harmonic Distortion Compensation
    Laurano, Christian
    Toscani, Sergio
    Zanoni, Michele
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 706 - 711