Chromatic VEP assessment of human macular pigment: Comparison with minimum motion and minimum flicker profiles

被引:12
|
作者
Robson, A. G.
Holder, G. E.
Moreland, J. D.
Kulikowski, J. J.
机构
[1] Moorfields Eye Hosp, Dept Electrophysiol, London EC1V 2PD, England
[2] Univ Manchester, Fac Life Sci, Visual Sci Lab, Manchester M60 1QD, Lancs, England
[3] Univ Manchester, Inst Sci & Technol, Manchester M60 1QD, Lancs, England
[4] Keele Univ, Keele, Staffs, England
关键词
macular pigment; VEP; motion photometry; koniocellulir; parvocellular; colour vision; Tritan selectivity;
D O I
10.1017/S0952523806232115
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
To assess the effects of macular pigment optical density (MPOD) on isoluminant stimuli and to quantify MPOD electrophysiologically, MPOD distribution profiles were obtained in normal Subjects using minimum motion and minimum flicker photometry. Isoluminance of VEP stimuli was determined using minimum flicker and tritan confusion lines were determined using a minimum distinct border criterion. Onset-offset and reversal VEPs to isoluminant red/green, blue/green, and subject-specific tritan gratings of different diameters were recorded from the same 14 subjects tested psychophysically. VEPs were additionally recorded to annular gratings. Chromatic VEP selectivity was assessed by Fourier analysis and as an index; onset negativity/(onset negativity + onset positivity). Peak MPOD varied between 0.2-0.8. Chromatic onset VEPs to all isoluminant 3-deg fields were predominantly negative. Larger blue/green and tritan stimuli elicited VEPs with additional positive, achromatic components; for 9-deg gratings, peak MPOD showed negative correlation with the power of the VEP fundamental (r = -0.70) and with the selectivity index (r = -0.83). Annular gratings elicited chromatic-specific B/G VEPs but only when isoluminance was determined for the annulus. Chromatic selectivity loss in VEPs to large B/G or Tritan gratings can be used to estimate subject-specific MPOD. An important implication is that isoluminant Tritan stimuli with short-wavelength components must be restricted in size in order to optimize koniocellular selectivity.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 50 条
  • [31] Minimum image quality assessment based on saliency maps: a human visual approach
    Barreira, Joao
    Bessa, Maximino
    Magalhaes, Luis
    IMAGE QUALITY AND SYSTEM PERFORMANCE X, 2013, 8653
  • [32] Human-robot cooperative manipulation with motion estimation using minimum-jerk model
    Maeda, Yusuke
    Hara, Takayuki
    Arai, Tamio
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2002, 68 (11): : 3367 - 3372
  • [33] Assessment of the validity of in vivo methods of measuring human macular pigment optical density -: Authors' response
    Hammond, BR
    Wooten, BR
    Smollon, B
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (04) : 256 - 259
  • [34] From dactyloscopy to the Minimum Surface Requirement (MSR): a metric to assess and obtain suitable human STR profiles
    Di Nunzio, Michele
    De Alcaraz-Fossoul, Josep
    Maroto-Nouveau, Vanessa
    Camprubi-Aumatell, Clara
    Barrot-Feixat, Carme
    FORENSIC SCIENCE INTERNATIONAL, 2025, 368
  • [35] Design of a Humanoid Shoulder Complex Emulating Human Shoulder Girdle Motion Using the Minimum Number of Actuators
    Newkrirk, Jeremy T.
    Stanisic, Michael M.
    INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2016, 13 (04)
  • [36] Comparison of minimum current estimate and dipole modeling in the analysis of simulated activity in the human visual cortices
    Stenbacka, L
    Vanni, S
    Uutela, K
    Hari, R
    NEUROIMAGE, 2002, 16 (04) : 936 - 943
  • [37] Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plate
    Yan Xiong
    Yu Feng Zhao
    Shu Xing Xing
    Quan Yin Du
    Hong Zhen Sun
    Zi Ming Wang
    Si Yu Wu
    Ai Min Wang
    International Orthopaedics, 2010, 34 : 715 - 718
  • [38] Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plate
    Xiong, Yan
    Zhao, Yu Feng
    Xing, Shu
    Du, Quan Yin
    Sun, Hong Zhen
    Wang, Zi Ming
    Wu, Si Yu
    Wang, Ai Min
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (05) : 715 - 718
  • [39] LIPIDS OF HUMAN RETINA, RETINAL-PIGMENT EPITHELIUM, AND BRUCH MEMBRANE CHOROID - COMPARISON OF MACULAR AND PERIPHERAL REGIONS
    GULCAN, HG
    ALVAREZ, RA
    MAUDE, MB
    ANDERSON, RE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (11) : 3187 - 3193
  • [40] Minimum energy reaction profiles for the hydrolysis reaction of the cyclic guanosine monophosphate in water: Comparison of the results of two QM/MM approaches
    Morozov, Dmitry
    Khrenova, Maria
    Andrijchenko, Natalya
    Grigorenko, Bella
    Nemukhin, Alexander
    COMPUTATIONAL AND THEORETICAL CHEMISTRY, 2012, 983 : 88 - 94