The effects of different sterilization procedures on the optical polymer oxygen sensors

被引:16
|
作者
Zajko, Spela [1 ]
Klimant, Ingo [1 ]
机构
[1] Graz Univ Technol, Inst Analyt Chem & Food Chem, A-8010 Graz, Austria
关键词
Sterilization; Polymer; Indicator; Fluorescence; Optical sensor; Polymer oxygen sensor; DIIMINE COMPLEXES; GLUCOSE; POLYSTYRENE; SENSITIVITY; BIOSENSORS; MEMBRANE; PROBES;
D O I
10.1016/j.snb.2012.10.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sterilization is a physical or chemical process that eliminates microbial life from a surface, equipment, medication, etc. Because of the severity of the process to meet the sterilization criteria and definition there is no singular sterilization applicable to all healthcare and other products including drugs, polymers, devices and materials. The sterility of sensors used in medical applications, for biochemical investigations, operation of biotechnological reactors, etc., is a necessary but difficult-to-achieve prerequisite for the use of sensors. There is a lack of reliable data about effects of different sterilization procedures on optical sensors. Therefore, the influences, effects and compatibility of diverse sterilization procedure on optical polymer oxygen sensors were investigated. Before and after sterilization, the absorption/emission spectra and the response of the sensor to different concentrations of oxygen were measured and Stern-Volmer plots were calculated. Based on the obtained results from measurements the compatibilities of the different sterilization procedures and polymer oxygen sensors were determined. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [21] Effects of pressure on oxygen sensors
    Atkinson, MJ
    Thomas, FIM
    Larson, N
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1996, 13 (06) : 1267 - 1274
  • [22] THE EFFECTS OF DISINFECTION AND STERILIZATION PROCEDURES ON THE CUTTING EFFICIENCY OF ENDODONTIC INSTRUMENTS
    HAIKEL, Y
    BLEICHER, P
    SERFATY, R
    ALLEMANN, C
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 938 - 938
  • [23] Effects of sterilization and disinfection procedures on the corrosion of orthodontic ligature cutters
    Benyahia, Hicham
    Merzouk, Nadia
    Touhami, Mohamed Ebn
    Zaoui, Fatima
    INTERNATIONAL ORTHODONTICS, 2012, 10 (01) : 1 - 15
  • [24] Sterilization effects on nitric oxide-releasing glucose sensors
    Bradshaw, Taron M.
    Johnson, Courtney R.
    Broberg, Christopher A.
    Anderson, Darci E.
    Schoenfisch, Mark H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 405
  • [25] Oxygen sensitive polymeric nanocapsules for optical dissolved oxygen sensors
    Sun, Zhijuan
    Cai, Chenxin
    Guo, Fei
    Ye, Changhuai
    Luo, Yingwu
    Ye, Shuming
    Luo, Jianchao
    Zhu, Fan
    Jiang, Chunyue
    NANOTECHNOLOGY, 2018, 29 (14)
  • [26] EFFECTS OF DIFFERENT STERILIZATION METHODS ON POLYESTER SURFACES
    Duzyer, Sebnem
    Koral Koc, Serpil
    Hockenberger, Asli
    Evke, Elif
    Kahveci, Zeynep
    Uguz, Agah
    TEKSTIL VE KONFEKSIYON, 2013, 23 (04): : 319 - 324
  • [27] Micro-patterning of polymer-based optical oxygen sensors for lab-on-chip applications
    Nock, Volker
    Blaikie, Richard J.
    David, Tim
    BIOMEMS AND NANOTECHNOLOGY III, 2008, 6799
  • [28] Optical fiber sensors embedded in polymer flexible
    Van Hoe, Bram
    Van Steenberge, Geert
    Bosman, Erwin
    Missinne, Jeroen
    Geernaert, Thomas
    Berghmans, Francis
    Webb, David
    Van Daele, Peter
    OPTICAL SENSING AND DETECTION, 2010, 7726
  • [29] Polymer single-nanowire optical sensors
    Gu, Fuxing
    Zhang, Lei
    Yin, Xuefeng
    Tong, Limin
    NANO LETTERS, 2008, 8 (09) : 2757 - 2761
  • [30] Optical Polymer Liquid Crystal Pressure Sensors
    Zharkova, G. M.
    Petrov, A. P.
    Kovrizhina, V. N.
    Pen, E. F.
    PROCEEDINGS OF THE XXV CONFERENCE ON HIGH-ENERGY PROCESSES IN CONDENSED MATTER (HEPCM 2017), 2017, 1893