High-resolution multichannel measurement and analysis of cardiac repolarization

被引:0
|
作者
Fereniec, Malgorzata [1 ]
Maniewski, Roman [1 ]
Karpinski, Grzegorz [2 ]
Opolski, Grzegorz [2 ]
Rix, Herve [3 ]
机构
[1] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
[2] Med Univ, Dept Cardiol, Warsaw, Poland
[3] Univ Nice, Sophia Antipolis, France
关键词
high-resolution ECG; repolarization phase; shape variability; myocardial infarction;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Time and spatial inhomogeneity of the repolarization phase is considered to be an important, noninvasive indication of sudden cardiac death in patients after myocardial infarction. Analysis of spatial variability of the repolarization phase was carried out on signals recorded with the 64-channel system for measurement of high-resolution ECG. The lead position on the torso, according to the University of Amsterdam lead system, was used. A new parameter, called the T-wave shape index and the distribution function method, as a method sensitive to shape variations, were applied to examine spatial variability of the T-wave shape in HR ECG maps. A group of 14 healthy volunteers and a group of 12 patients after myocardial infarction were studied. The diversity of spatial distributions of the parameters connected to the shape of the T-wave is clearly noticeable in the group of patients after myocardial infarction. The similarity of spatial distributions of proposed parameters in the group of healthy subjects is observed. The obtained results confirm the hypothesis that the spatial heterogeneity of the repolarization phase increases after myocardial infarction.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [31] HIGH-RESOLUTION ANALYSIS OF INTERFACES
    NORDEN, H
    ANDREN, HO
    [J]. ULTRAMICROSCOPY, 1988, 24 (01) : 73 - 74
  • [32] HIGH-RESOLUTION INTERFACE ANALYSIS
    CARPENTER, RW
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1989, 107 : 207 - 216
  • [33] High-Resolution NIR Analysis
    Morris, R.
    [J]. SPECTROSCOPY, 2010, 25 (12) : 90 - 90
  • [34] High-resolution modal analysis
    Ege, Kerem
    Boutillon, Xavier
    David, Bertrand
    [J]. JOURNAL OF SOUND AND VIBRATION, 2009, 325 (4-5) : 852 - 869
  • [35] A Wearable, High-Resolution, and Wireless System for Multichannel Surface Electromyography Detection
    Zhu, Lisen
    Mao, Guangwei
    Su, Hao
    Zhou, Zhijun
    Li, Wenyuan
    Lu, Xiaoying
    Wang, Zhigong
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (08) : 9937 - 9948
  • [36] A HIGH-RESOLUTION, MULTICHANNEL DIGITAL-TO-ANALOG CONVERTER FOR DIGITAL OSCILLOSCOPES
    GARNETT, GH
    [J]. HEWLETT-PACKARD JOURNAL, 1992, 43 (01): : 48 - &
  • [37] HIGH-RESOLUTION SINGLE CHANNEL NEUROMAGNETOMETRY AND MINIMAL APPROACH FOR MULTICHANNEL SYSTEMS
    THOMAS, T
    DURET, D
    [J]. CRYOGENICS, 1988, 28 (11) : 783 - 795
  • [38] MULTICHANNEL POWER ANALYZER OF NEUTRAL RECHARGE PARTICLES WITH HIGH-RESOLUTION IN TIME
    BORZENKO, VP
    KOSHILEV, NA
    PARFENOV, OG
    STROKIN, NA
    [J]. ZHURNAL TEKHNICHESKOI FIZIKI, 1978, 48 (06): : 1174 - 1177
  • [39] MULTICHANNEL DETECTION HIGH-RESOLUTION ELECTRON-ENERGY LOSS SPECTROMETER
    JEONG, EJ
    ERSKINE, JL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3139 - 3150
  • [40] Blind multichannel reconstruction of high-resolution images using wavelet fusion
    El-Khamy, SE
    Hadhoud, MM
    Dessouky, MI
    Salam, BM
    Abd El-Samie, FE
    [J]. APPLIED OPTICS, 2005, 44 (34) : 7349 - 7356