High-resolution multichannel measurement and analysis of cardiac repolarization

被引:0
|
作者
Fereniec, Malgorzata [1 ]
Maniewski, Roman [1 ]
Karpinski, Grzegorz [2 ]
Opolski, Grzegorz [2 ]
Rix, Herve [3 ]
机构
[1] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
[2] Med Univ, Dept Cardiol, Warsaw, Poland
[3] Univ Nice, Sophia Antipolis, France
关键词
high-resolution ECG; repolarization phase; shape variability; myocardial infarction;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Time and spatial inhomogeneity of the repolarization phase is considered to be an important, noninvasive indication of sudden cardiac death in patients after myocardial infarction. Analysis of spatial variability of the repolarization phase was carried out on signals recorded with the 64-channel system for measurement of high-resolution ECG. The lead position on the torso, according to the University of Amsterdam lead system, was used. A new parameter, called the T-wave shape index and the distribution function method, as a method sensitive to shape variations, were applied to examine spatial variability of the T-wave shape in HR ECG maps. A group of 14 healthy volunteers and a group of 12 patients after myocardial infarction were studied. The diversity of spatial distributions of the parameters connected to the shape of the T-wave is clearly noticeable in the group of patients after myocardial infarction. The similarity of spatial distributions of proposed parameters in the group of healthy subjects is observed. The obtained results confirm the hypothesis that the spatial heterogeneity of the repolarization phase increases after myocardial infarction.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [1] Novel methods for high-resolution assessment of cardiac action potential repolarization
    Meo, Marianna
    Meste, Olivier
    Signore, Sergio
    Rota, Marcello
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 51 : 30 - 41
  • [2] HIGH-RESOLUTION MULTICHANNEL INTERFEROMETRIC MEASUREMENT OF SAWTOOTH DENSITY-PULSE PROPAGATION
    KIM, SK
    BROWER, DL
    PEEBLES, WA
    LUHMANN, NC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1550 - 1555
  • [3] HIGH-RESOLUTION DECAMETER MULTICHANNEL RADIO SPECTROGRAPH
    LECACHEUX, A
    ROSOLEN, C
    [J]. ASTRONOMY & ASTROPHYSICS, 1975, 41 (02) : 223 - 227
  • [4] Using high-resolution displays for high-resolution cardiac data
    Goodyer, Christopher
    Hodrien, John
    Wood, Jason
    Kohl, Peter
    Brodlie, Ken
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 367 (1898): : 2667 - 2677
  • [5] HIGH-RESOLUTION AUTORADIOGRAPHIC MEASUREMENT OF REGIONAL CARDIAC OXIDATIVE-METABOLISM
    LEAR, JL
    KASLIWAL, R
    DURYEA, RA
    PRATT, JP
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05): : P98 - P98
  • [6] HIGH-RESOLUTION WITH HIGH-FOLD, MULTICHANNEL SEISMIC SYSTEMS
    ALLEN, SJ
    [J]. GEOPHYSICS, 1977, 42 (05) : 1100 - 1100
  • [7] MULTICHANNEL RECORDING OF ELECTRONS IN A HIGH-RESOLUTION BETA SPECTROMETER
    DAVIDONIS, RY
    ZHIRGULYAVICHYUS, RK
    KALINAUSKAS, RA
    MAKARYUNAS, KV
    REMEIKIS, VV
    STEPONAVICHYUS, SI
    TAMOLYUNAS, II
    [J]. MEASUREMENT TECHNIQUES USSR, 1989, 32 (07): : 721 - 724
  • [8] HIGH-RESOLUTION MULTICHANNEL CARS SPECTRA IN COMBUSTION RESEARCH
    RIMAI, L
    MARKO, KA
    KLICK, DI
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1981, 17 (12) : 154 - 154
  • [9] High-resolution multichannel instrument for resonant sensor array
    Ferrari, P
    Flammini, A
    Marioli, D
    Taroni, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (03) : 932 - 937
  • [10] CALIBRATION OF A MULTICHANNEL DETECTOR COUPLED TO A HIGH-RESOLUTION SPECTROMETER
    BRADLEY, MS
    KRECH, JH
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (08): : 2040 - 2041