Positional and Curvature Difference of Lamina Cribrosa According to the Baseline Intraocular Pressure in Primary Open-Angle Glaucoma: A Swept-Source Optical Coherence Tomography (SS-OCT) Study

被引:20
|
作者
Kim, Yong Woo [1 ]
Jeoung, Jin Wook [2 ]
Girard, Michael J. A. [3 ,4 ]
Mari, Jean Martial [5 ]
Park, Ki Ho [2 ]
机构
[1] Armed Forces Capital Hosp, Dept Ophthalmol, Songnam, South Korea
[2] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
[3] Natl Univ Singapore, Dept Biomed Engn, Singapore, Singapore
[4] Singapore Eye Res Inst, Singapore, Singapore
[5] Univ French Polynesia, Tahiti, France
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
RETINAL VESSEL TRUNK; NERVE HEAD; REGIONAL DIFFERENCES; NEURORETINAL RIM; VISUAL-FIELD; DISC; ENHANCEMENT; AGE; DISPLACEMENT; VISIBILITY;
D O I
10.1371/journal.pone.0162182
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate the variation of lamina cribrosa (LC) structure based on the baseline intraocular pressure (IOP) in eyes with primary open-angle glaucoma (POAG) and healthy individuals using swept-source optical coherence tomography. Methods A total of 108 eyes with POAG and 61 healthy eyes were recruited. Based on the baseline IOP, the POAG eyes were divided into higher-baseline IOP (HTG; baseline IOP > 21 mmHg, n = 38 eyes) and lower-baseline IOP (NTG; baseline IOP <= 21 mmHg, n = 70 eyes). The anterior laminar insertion depth (ALID), mean LC depth (mLCD), and the LC curvature index (mLCD-ALID) were measured, and compared among the three groups. The regional variation of LC structure was evaluated by vertical-horizontal ALID difference. Results The mLCD and LC curvature index were greatest in HTG eyes (520.3 +/- 123.0 and 80.9 +/- 30.7 mu m), followed by NTG (463.2 +/- 110.5 and 64.5 +/- 30.7 mu m) and healthy eyes (382.9 +/- 107.6 and 47.6 +/- 25.7 mu m, all P < 0.001). However, there were no significant difference in ALID between HTG and NTG eyes. The vertical-horizontal ALID difference was larger in NTG eyes (72.8 +/- 56.2 mu m) than in HTG (32.7 +/- 61.4 mu m, P = 0.004) and healthy eyes (25.5 +/- 34.8 mu m, P < 0.001). Conclusions Lamina cribrosa position and curvature differed in POAG eyes with low and high IOP. This would support the theory that IOP induced biomechanical effects on the optic play a role on glaucoma.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Visualization of the Lamina Cribrosa Microvasculature in Normal and Glaucomatous Eyes: A Swept-source Optical Coherence Tomography Angiography Study
    Numa, Shogo
    Akagi, Tadamichi
    Uji, Akihito
    Suda, Kenji
    Nakanishi, Hideo
    Kameda, Takanori
    Ikeda, Hanako Ohashi
    Tsujikawa, Akitaka
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (11) : 1032 - 1035
  • [32] Diagnostic Accuracy of Wide-Field Map from Swept-Source Optical Coherence Tomography for Primary Open-Angle Glaucoma in Myopic Eyes
    Kim, Yong Woo
    Lee, Jinho
    Kim, Jin-Soo
    Park, Ki Ho
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 182 - 191
  • [33] Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo
    Shimada, Yasushi
    Nakagawa, Hisaichi
    Sadr, Alireza
    Wada, Ikumi
    Nakajima, Masatoshi
    Nikaido, Toru
    Otsuki, Masayuki
    Tagami, Junji
    Sumi, Yasunori
    [J]. JOURNAL OF BIOPHOTONICS, 2014, 7 (07) : 506 - 513
  • [34] Optical evaluation of enamel white spot lesions around orthodontic brackets using swept-source optical coherence tomography (SS-OCT): An in vitro study
    Velusamy, Pavethynath
    Shimada, Yasushi
    Kanno, Zuisei
    Ono, Takashi
    Tagami, Junji
    [J]. DENTAL MATERIALS JOURNAL, 2019, 38 (01) : 22 - 27
  • [35] Measurement of Structural Parameters of the Lamina Cribrosa in Primary Open-Angle Glaucoma and Chronic Primary Angle-Closure Glaucoma by Optical Coherence Tomography and Its Correlations with Ocular Parameters
    Hao, Linlin
    Xiao, Hui
    Gao, Xue
    Xu, Xiaoyu
    Liu, Xing
    [J]. OPHTHALMIC RESEARCH, 2019, 62 (01) : 36 - 45
  • [36] Evaluation of lamina cribrosa parameters, nerve fiber thickness, and macular thickness in primary open-angle glaucoma and pseudoexfoliation glaucoma using optical coherence tomography
    Baskan, Burhan
    Atas, Mustafa
    Demircan, Suleyman
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [37] Optical coherence tomography in the evaluation of structural changes in primary open-angle glaucoma with and without elevated intraocular pressure
    Bolinovic, Marija Trenkic
    Zlatanovic, Gordana
    Jovanovic, Predrag
    Veselinovic, Dragan
    Jocic, Jasmina Djordjevic
    Radenkovic, Marija
    Resan, Mirko
    [J]. VOJNOSANITETSKI PREGLED, 2016, 73 (07) : 618 - 625
  • [38] Assessment of defects at tooth/self-adhering flowable composite interface using swept-source optical coherence tomography (SS-OCT)
    Park, Kyung-Jin
    Schneider, Hartmut
    Haak, Rainer
    [J]. DENTAL MATERIALS, 2015, 31 (05) : 534 - 541
  • [39] Estimated trans-lamina cribrosa pressure difference versus intraocular pressure as biomarker for open-angle glaucoma. The Beijing Eye Study 2011
    Jonas, Jost B.
    Wang, Ning Li
    Wang, Ya Xing
    You, Qi Sheng
    Xie, Xiao Bin
    Yang, Di Ya
    Xu, Liang
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93 (01) : E7 - E13
  • [40] Agreement between a new swept-source optical coherence tomography (ss-OCT) and a Placido disc - Dual Scheimpflug ocular biometric devices
    Seo, Shiney
    McLintock, Cameron
    Niyazmand, Hamed
    Barrett, Graham
    McKelvie, James
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 880 - 880