Identification of M Protein From Filter Paper Using Serum Protein and Immunofixation Electrophoresis

被引:2
|
作者
Wu, Yonghua [1 ]
Yang, Xu [1 ]
Wang, Tiancheng [1 ]
Wang, Haining [2 ]
Li, Zhenrong [1 ]
机构
[1] Peking Univ, Dept Lab Med, Hosp 3, Beijing 100191, Peoples R China
[2] Peking Univ, Dept Endocrinol, Hosp 3, Beijing 100191, Peoples R China
关键词
Serum protein electrophoresis; Immunofixation electrophoresis; M (monoclonal) protein; Filter paper; BLOOD SPOT SAMPLES; MULTIPLE-MYELOMA; STORAGE;
D O I
10.1309/AJCPFY6HLIT6HMQN
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are standard methods for detection and monitoring of monoclonal (M) proteins. However, these tests are rarely available in the remote areas, especially in developing countries. Transportation of fresh serum (FS) samples is also usually inconvenient. This study investigated M-protein identification using serum blot on filter paper (FP). SPE and IFE were performed on FS and FP specimens using the Sebia Hydrasys automated electrophoresis system. Statistical analyses were conducted to assess sample stability and agreement of FS vs FP. The FP method showed good agreement with the FS method. The r values for correlation of albumin levels-alpha(1), alpha(2), beta, and gamma (%)-between FP and FS samples in SPE were all more than 0.95 (P < .01). IFE displayed no significant difference between those 2 methods in the identification of M protein. The FP method demonstrated an accurate and reproducible alternative to FS for identification of M protein using SPE and IFE.
引用
收藏
页码:604 / 608
页数:5
相关论文
共 50 条
  • [21] SERUM PROTEIN PAPER ELECTROPHORESIS IN PATIENTS WITH CYSTIC FIBROSIS
    GREEN, MN
    KULCZYCKI, LL
    SHWACHMAN, H
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1960, 100 (03): : 365 - 372
  • [22] 74-Year-old female with new monoclonal protein on serum immunofixation electrophoresis
    Cenaj, Odise
    Dahlin, Jayme L.
    Buencamino, Dulce M.
    Laubach, Jacob P.
    Jarolim, Petr
    CLINICAL BIOCHEMISTRY, 2018, 51 : 97 - 100
  • [23] Significance of serum free light chain estimation with detectable serum monoclonal protein on immunofixation electrophoresis.
    Mehta, Jayesh
    Stein, Regina
    Vickrey, Eric
    Resseguie, William
    Singhal, Seema
    BLOOD, 2006, 108 (11) : 351B - 351B
  • [24] A STUDY OF THE SERUM PROTEIN CHANGES IN PREGNANCY AND TOXAEMIA, USING PAPER STRIP ELECTROPHORESIS
    MACGILLIVRAY, I
    TOVEY, JE
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1957, 64 (03) : 361 - 364
  • [25] Evaluation of two semi-automated methods for serum protein and immunofixation electrophoresis.
    Csako, G
    Tran, A
    Wang, J
    Chesler, R
    Costello, R
    CLINICAL CHEMISTRY, 1999, 45 (06) : A46 - A47
  • [27] A comparison between high resolution serum protein electrophoresis and screening immunofixation for the detection of monoclonal gammopathies in serum
    Smith, Joel
    Raines, Geoffrey
    Schneider, Hans-Gerhard
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (02) : 256 - 263
  • [28] The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis
    Ellidag, Hamit Yasar
    Curek, Gulten
    Eren, Esin
    Aydin, Ozgur
    Yilmaz, Necat
    CLINICAL LABORATORY, 2015, 61 (10) : 1525 - 1530
  • [29] Predictive Value of Hypogammaglobulinemia in Monoclonal Gammopathies Detected by Reflex Immunofixation of Serum Protein Electrophoresis Samples
    Manthei, David
    Schroeder, Lee
    Keren, David
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2016, 146 : S37 - S37
  • [30] Isatuximab-Specific Immunofixation Electrophoresis Assay to Remove Interference in Serum M-Protein Measurement in Patients with Multiple Myeloma
    Thoren, Katie
    Menad, Samia
    Nouadje, Georges
    Mace, Sandrine
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2024, : 661 - 671