Identification of M Protein From Filter Paper Using Serum Protein and Immunofixation Electrophoresis

被引:2
|
作者
Wu, Yonghua [1 ]
Yang, Xu [1 ]
Wang, Tiancheng [1 ]
Wang, Haining [2 ]
Li, Zhenrong [1 ]
机构
[1] Peking Univ, Dept Lab Med, Hosp 3, Beijing 100191, Peoples R China
[2] Peking Univ, Dept Endocrinol, Hosp 3, Beijing 100191, Peoples R China
关键词
Serum protein electrophoresis; Immunofixation electrophoresis; M (monoclonal) protein; Filter paper; BLOOD SPOT SAMPLES; MULTIPLE-MYELOMA; STORAGE;
D O I
10.1309/AJCPFY6HLIT6HMQN
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are standard methods for detection and monitoring of monoclonal (M) proteins. However, these tests are rarely available in the remote areas, especially in developing countries. Transportation of fresh serum (FS) samples is also usually inconvenient. This study investigated M-protein identification using serum blot on filter paper (FP). SPE and IFE were performed on FS and FP specimens using the Sebia Hydrasys automated electrophoresis system. Statistical analyses were conducted to assess sample stability and agreement of FS vs FP. The FP method showed good agreement with the FS method. The r values for correlation of albumin levels-alpha(1), alpha(2), beta, and gamma (%)-between FP and FS samples in SPE were all more than 0.95 (P < .01). IFE displayed no significant difference between those 2 methods in the identification of M protein. The FP method demonstrated an accurate and reproducible alternative to FS for identification of M protein using SPE and IFE.
引用
收藏
页码:604 / 608
页数:5
相关论文
共 50 条
  • [1] Test Utilization of Serum Protein Electrophoresis and Immunofixation Electrophoresis
    Katerji, Roula
    Paczos, Tamera
    Liu, Li
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 152 : S146 - S147
  • [2] Serum protein electrophoresis and immunofixation by a semiautomated electrophoresis system
    Bossuyt, X
    Bogaerts, A
    Schiettekatte, G
    Blanckaert, N
    CLINICAL CHEMISTRY, 1998, 44 (05) : 944 - 949
  • [3] Resolution of Discrepant Results in Serum Protein Electrophoresis and Immunofixation Electrophoresis
    Vick, Randol
    Blakely, Katherine
    Taylor, Sara
    Han, Heping
    Lewis, Sally
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 149 : S10 - S10
  • [4] Serum Protein Electrophoresis and Immunofixation Electrophoresis Detection in Multiple Myeloma
    Zhu, Shanshan
    Li, Wei
    Lin, Meilin
    Li, Tiemin
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (07): : 864 - 867
  • [5] Detection by immunofixation of M proteins in hypogammaglobulinemic patients with normal serum protein electrophoresis results
    Lakshminarayanan, Renuka
    Li, Yueju
    Janatpour, Kim
    Beckett, Laurel
    Jialal, Ishwarlal
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 127 (05) : 746 - 751
  • [6] CLINICAL SIGNIFICANCE OF THE ANALYSIS OF SERUM PROTEIN DISTRIBUTION BY FILTER PAPER ELECTROPHORESIS
    JENCKS, WP
    SMITH, ERB
    DURRUM, EL
    AMERICAN JOURNAL OF MEDICINE, 1956, 21 (03): : 387 - 405
  • [7] DISTRIBUTION OF LIPIDS IN SERUM PROTEIN FRACTIONS SEPARATED BY ELECTROPHORESIS IN FILTER PAPER
    NIKKILA, E
    ANNALES MEDICINAE EXPERIMENTALIS ET BIOLOGIAE FENNIAE, 1952, 30 (02): : 331 - 336
  • [8] Posttreatment Persistence of Monoclonal Protein on Immunofixation Electrophoresis but Absence on Serum Protein Electrophoresis in a Case of Solitary Bone Plasmacytoma
    Kumar, Visesh
    Rani, Priti
    Rai, Neha
    Kumar, Subhash
    Mahto, Mala
    JOURNAL OF LABORATORY PHYSICIANS, 2023, 15 (01) : 162 - 165
  • [9] STAINING OF PROTEIN-BOUND CARBOHYDRATES AFTER ELECTROPHORESIS OF SERUM ON FILTER PAPER
    KOIW, E
    GRONWALL, A
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1952, 4 (03): : 244 - 246
  • [10] Synoptic reporting for protein electrophoresis and immunofixation
    McCudden, Christopher R.
    Booth, Ronald A.
    Lin, Danny C. C.
    McCurdy, Arleigh
    Rupani, Natasha
    Kew, Andrea
    CLINICAL BIOCHEMISTRY, 2018, 51 : 21 - 28