Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography

被引:27
|
作者
Barnabe, Cheryl [1 ,2 ]
Buie, Helen [3 ]
Kan, Michelle [3 ]
Szabo, Eva [3 ]
Barr, Susan G. [1 ,2 ]
Martin, Liam [1 ]
Boyd, Steven K. [3 ,4 ]
机构
[1] Univ Calgary, Dept Med, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Dept Community Hlth Sci, Calgary, AB T2N 1N4, Canada
[3] Univ Calgary, Schulich Sch Engn, Calgary, AB T2N 1N4, Canada
[4] Univ Calgary, Dept Radiol, Calgary, AB T2N 1N4, Canada
关键词
Musculoskeletal imaging; Rheumatoid arthritis; X-RAY RADIOGRAMMETRY; RHEUMATOID-ARTHRITIS; BONE LOSS; HAND; RADIOGRAPHS; EROSIONS; WRIST;
D O I
10.1016/j.medengphy.2013.04.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography (HR-pQCT) (Scanco Medical AG, Bruttisellen, Switzerland) accurately and reproducibly images bone microstructure at a nominal isotropic voxel dimension of 82 mu m. Given the ability of HR-pQCT to detect bone margins with high precision, we developed methodology to measure a three-dimensional (3D) metacarpophalangeal (MCP) joint space width and tested the reproducibility of the scan protocol with hand repositioning. Materials and methods: Consecutive HR-pQCT scans of the 2nd and 3rd MCP joints of ten subjects with early RA (70% female, mean age 45 years), with repositioning between scans, were obtained. The periosteal edges of the metacarpal head and proximal phalanx base were detected using the mu CT Evaluation Program V6.0 (Scanco Medical AG). Using the method of 'fitting maximal spheres', the joint space width and distribution of joint space thickness was estimated. Results: The mean minimum joint space width of the 2nd MCP was 1.82 mm (SD 0.20) and of the 3rd MCP 1.84 mm (SD 0.23). Reproducibility with repositioning was reliable, with overlapping filtered histograms and a root square mean coefficient of variance of 4.8%. Conclusions: We provide reproducible methodology for evaluating the joint space width of the MCP joints. When combined with the assessment of erosions and periarticular bone density, HR-pQCT may be the ideal technology to assess disease activity and progression in RA. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1540 / 1544
页数:5
相关论文
共 50 条
  • [21] High-resolution Terahertz Computed Tomography Using 3D Printed Diffractive Elements (Invited)
    Wang Dayong
    Ning Ran
    Jin Xiaoyu
    Rong Lu
    Zhao Jie
    Wang Yunxin
    Lin Shufeng
    ACTA PHOTONICA SINICA, 2022, 51 (07)
  • [22] FEASIBILITY OF JOINT STRUCTURAL ANALYSIS IN HEMOCHROMATOSIS HAND ARTHROPATHY USING HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY - FIRST RESULTS AND CLINICAL CORRELATIONS
    Heilmeier, U. R.
    Burghard, A. J.
    Kapoor, P.
    Voll, R. E.
    Finzel, S.
    ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 : 821 - 822
  • [23] Determining Metacarpophalangeal Flexion Angle Tolerance for Reliable Volumetric Joint Space Measurements by High-resolution Peripheral Quantitative Computed Tomography (vol 43, pg 1941, 2016)
    Tom, S.
    Frayne, M.
    Manske, S. L.
    Burghardt, A. J.
    Stok, K. S.
    Boyd, S. K.
    Barnabe, C.
    JOURNAL OF RHEUMATOLOGY, 2016, 43 (12) : 2201 - 2201
  • [24] Cortical measurements of the tibia from high resolution peripheral quantitative computed tomography images: A comparison with synchrotron radiation micro-computed tomography
    Ostertag, Agnes
    Peyrin, Francoise
    Fernandez, Sylvie
    Laredo, Jean Denis
    de Vernejoul, Marie Christine
    Chappard, Christine
    BONE, 2014, 63 : 7 - 14
  • [25] Accuracy of individualized 3D modeling of ossicles using high-resolution computed tomography imaging data
    Zhao, Danheng
    Lu, Qiaohui
    Zou, Shizhen
    Sun, Jianjun
    Hu, Fazong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2406 - 2414
  • [26] Erosion Identification in Metacarpophalangeal Joints in Rheumatoid Arthritis using High-Resolution Peripheral Quantitative Computed Tomography
    Al-Khoury, Yousif
    Finzel, Stephanie
    Figueiredo, Camille
    Burghardt, Andrew J.
    Stok, Kathryn S.
    Tam, Lai-Shan
    Cheng, Isaac
    Tse, Justin J.
    Manske, Sarah L.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):
  • [27] Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
    D.E. Whittier
    S.K. Boyd
    A.J. Burghardt
    J. Paccou
    A. Ghasem-Zadeh
    R. Chapurlat
    K. Engelke
    M.L. Bouxsein
    Osteoporosis International, 2020, 31 : 1607 - 1627
  • [28] Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
    Whittier, D. E.
    Boyd, S. K.
    Burghardt, A. J.
    Paccou, J.
    Ghasem-Zadeh, A.
    Chapurlat, R.
    Engelke, K.
    Bouxsein, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (09) : 1607 - 1627
  • [29] IN VIVO MEASUREMENTS OF CORTICAL THICKNESS AND POROSITY AT THE PROXIMAL THIRD OF THE TIBIA USING GUIDED WAVES: COMPARISON WITH SITE-MATCHED PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND DISTAL HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY
    Schneider, Johannes
    Ramiandrisoa, Donatien
    Armbrecht, Gabriele
    Ritter, Zully
    Felsenberg, Dieter
    Raum, Kay
    Minonzio, Jean-Gabriel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05): : 1234 - 1242
  • [30] Optical computed and emission tomography for high-resolution 3D imaging of xenograft tumors
    Sakhalkar, H. S.
    Oliver, T.
    Dewhirst, M.
    Oldham, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S18 - S19