Assessment of cortical bone with clinical and ultrashort echo time sequences

被引:60
|
作者
Du, Jiang [1 ]
Hermida, Juan C. [2 ]
Diaz, Eric [1 ]
Corbeil, Jacqueline [1 ]
Znamirowski, Richard [1 ]
D'Lima, Darryl D. [2 ]
Bydder, Graeme M. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Scripps Res Inst, Dept Mol & Expt Med, La Jolla, CA 92037 USA
关键词
ultrashort echo time; projection reconstruction; adiabatic inversion; cortical bone; free water; bound water; SPECTROSCOPIC IMAGING UTESI; RF EXCITATION; BOUND WATER; MRI; CONTRAST; POROSITY; DENSITY; MATRIX; SIGNAL; PORE;
D O I
10.1002/mrm.24497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe the use of ultrashort echo time (UTE) sequences and fast spin echo sequences to assess cortical bone using a clinical 3T scanner. Regular two- and three-dimensional UTE sequences were used to image both bound and free water in cortical bone. Adiabatic inversion recovery prepared UTE sequences were used to image water bound to the organic matrix. Two-dimensional fast spin echo sequences were used to image free water. Regular UTE sequences were used together with bicomponent analysis to measure T*(2)s and relative fractions of bound and free water components in cortical bone. Inversion recovery prepared UTE sequences were used to measure the T*(2) of bound water. Saturation recovery UTE sequences were used to measure the T-1 of bone water. Eight cadaveric human cortical bone samples and a lower leg specimen were studied. Preliminary results show two distinct components in UTE detected signal decay, a single component in inversion recovery prepared UTE detected signal decay, and a single component in saturation recovery UTE detected signal recovery. Regular UTE sequences appear to depict both bound and free water in cortical bone. Inversion recovery prepared UTE sequences appear to depict water bound to the organic matrix. Two-dimensional fast spin echo sequences appear to depict bone structure corresponding to free water in large pores. Magn Reson Med 70:697-704, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 50 条
  • [1] Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone
    Du, Jiang
    Hamilton, Gavin
    Takahashi, Atsushi
    Bydder, Mark
    Chung, Christine B.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 1001 - 1009
  • [2] Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
    Du, Jiang
    Carl, Michael
    Bydder, Mark
    Takahashi, Atsushi
    Chung, Christine B.
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 304 - 311
  • [3] Review of the ultrashort echo time magnetic resonance imaging of cortical bone
    Bao Shang-Lian
    Du Jiang
    Gao Song
    ACTA PHYSICA SINICA, 2013, 62 (08)
  • [4] A Feasibility Study of Ultrashort Echo Time Imaging of Cortical Bone at 0.35 T
    Huang, Yuli
    Du, Yiping P.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (07) : 1409 - 1414
  • [5] Simultaneous Quantitative Susceptibility Mapping of Articular Cartilage and Cortical Bone of Human Knee Joint Using Ultrashort Echo Time Sequences
    Zhang, Ming
    Li, Zhihui
    Wang, Hanqi
    Chen, Tongtong
    Lu, Yong
    Yan, Fuhua
    Zhang, Yuyao
    Wei, Hongjiang
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [6] Clinical ultrashort echo time imaging of bone and other connective tissues
    Robson, Matthew D.
    Bydder, Graeme M.
    NMR IN BIOMEDICINE, 2006, 19 (07) : 765 - 780
  • [7] Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone
    Chang, Eric Y.
    Bae, Won C.
    Shao, Hongda
    Biswas, Reni
    Li, Shihong
    Chen, Jun
    Patil, Shantanu
    Healey, Robert
    D'Lima, Darryl D.
    Chung, Christine B.
    Du, Jiang
    NMR IN BIOMEDICINE, 2015, 28 (07) : 873 - 880
  • [8] Cortical bone water: In vivo quantification with ultrashort echo-time MR imaging
    Techawiboonwong, Aranee
    Song, Hee Kwon
    Leonard, Mary B.
    Wehrli, Felix W.
    RADIOLOGY, 2008, 248 (03) : 824 - 833
  • [9] 3D printed phantoms mimicking cortical bone for the assessment of ultrashort echo time magnetic resonance imaging
    Rai, Robba
    Manton, David
    Jameson, Michael G.
    Josan, Sonal
    Barton, Michael B.
    Holloway, Lois C.
    Liney, Gary P.
    MEDICAL PHYSICS, 2018, 45 (02) : 758 - 766
  • [10] Ultrashort echo time magnetic resonance imaging (UTE-MRI) of cortical bone correlates well with histomorphometric assessment of bone microstructure
    Jerban, Saeed
    Ma, Yajun
    Wong, Jonathan H.
    Nazaran, Amin
    Searleman, Adam
    Wan, Lidi
    Williams, Judith
    Du, Jiang
    Chang, Eric Y.
    BONE, 2019, 123 : 8 - 17