Noninvasive pH Monitoring in Platelet Concentrates

被引:7
|
作者
Doescher, Andrea [1 ]
Mueller, Thomas H. [2 ]
机构
[1] DRK Blutspendedienst NSTOB, Inst Bremen Oldenburg, D-26133 Oldenburg, Germany
[2] DRK Blutspendedienst NSTOB, Inst Springe, Springe, Germany
关键词
Noninvasive pH measurement; Platelet concentrates; Donor screening; STORAGE; QUALITY;
D O I
10.1159/000350220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: New technology introduces the option to measure pH in platelet concentrates noninvasively. Findings that in one out of 25 apheresis concentrates the pH decreased significantly during storage motivated us to evaluate apheresis concentrates from 307 platelet donors. Methods: Small (15 ml) BSCI storage containers for noninvasive pH measurement were used in parallel with Fenwal PL2400 bags for storage of 5 days. Noninvasive pH measurement was compared to pH determination in samples from the storage container. Decrease of pH during storage was calculated as Delta pH d2-d5. Results: The coefficient of correlation for noninvasive pH measurement (n = 256) versus standard methods was R-2 = 0.964 (pH electrode) or 0.952 (ABL 510). pH values in BSCI bags were slightly lower than in Fenwal PL2400 containers. Concentrates collected from 8 of the 307 donors showed a significant drop in pH. Repeated collection did not confirm these findings with a single exception. Conclusion: Noninvasive pH measurement demonstrates a high reproducibility. Our study could not confirm the frequency of 1 out of 25 plateletpheresis donors with concentrates developing a significant drop in pH during storage. This may be due to a substantially lower platelet concentration in our preparations.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [31] PH CHANGES CAUSED BY BACTERIAL-GROWTH IN CONTAMINATED PLATELET CONCENTRATES
    MYHRE, BA
    DEMIANEW, SH
    YOSHIMORI, RN
    NELSON, EJ
    CARMEN, RA
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1985, 15 (06): : 509 - 514
  • [32] Correlation of PGD test result and pH of platelet concentrates inoculated with bacteria
    Hall, J
    Lajoie, C
    TRANSFUSION, 2004, 44 (09) : 49A - 49A
  • [33] Using BCSI PH1000 to Find Platelet Concentrates with Low PH or Bacterial Contamination
    Bosgoed, C.
    Kraan, M.
    Dijkstra-Tiekstra, M. J.
    de Korte, D.
    de Wildt-Eggen, J.
    TRANSFUSION, 2010, 50 : 66A - 66A
  • [34] RELATIONSHIP BETWEEN HIGH PLATELET COUNTS AND LOW PH OF ROOM-TEMPERATURE STORED PLATELET CONCENTRATES
    ZUCK, TF
    POLESKY, HF
    BRITT, C
    BARBER, JA
    TRANSFUSION, 1974, 14 (05) : 513 - 513
  • [35] MONITORING HEMOSTATIC POTENTIAL OF PLATELETS DURING STORAGE OF PLATELET CONCENTRATES FOR TRANSFUSION
    Giaccherini, C.
    Marchetti, M.
    Verzeroli, C.
    Tartari, C. J.
    Russo, L.
    Vignoli, A.
    Diani, E.
    Woodhams, B.
    Falanga, A.
    HAEMATOLOGICA, 2015, 100 : 629 - 630
  • [36] Relationships between parameters used for routine quality monitoring of platelet concentrates
    Callera, F
    DeMelo, CMTP
    TRANSFUSION MEDICINE, 2005, 15 (02) : 161 - 162
  • [38] Quality control on platelet concentrates: Relationship swirl, pH and P-selectin
    McShine, RL
    deWit, HJC
    Das, PC
    Sibinga, CTS
    TRANSFUSION, 1997, 37 (09) : S374 - S374
  • [39] Comparison of pH in platelet concentrates with additive solutions III modified for 9 days
    de Valensart, N. V.
    Leclercq, M.
    Rapaille, A.
    Sondag, D.
    VOX SANGUINIS, 2006, 91 : 267 - 267
  • [40] Precise pH measuring of platelet concentrates containing additive solution - the impact of the temperature
    Ringwald, J.
    Luther, R.
    Zimmermann, R.
    Strobel, J.
    Weiss, D.
    Eckstein, R.
    VOX SANGUINIS, 2012, 103 (01) : 49 - 54