Click-evoked vestibulo-ocular reflex - Stimulus-response properties in superior canal dehiscence

被引:39
|
作者
Aw, ST [1 ]
Todd, MJ
Aw, GE
Magnussen, JS
Curthoys, IS
Halmagyi, GM
机构
[1] Royal Prince Alfred Hosp, Dept Neurol, Sydney, NSW 2050, Australia
[2] Univ Sydney, Sch Psychol, Sydney, NSW, Australia
关键词
D O I
10.1212/01.wnl.0000204445.81884.c7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: An enlarged, low-threshold click-evoked vestibulo-ocular reflex (VOR) can be averaged from the vertical electro-oculogram in a superior canal dehiscence (SCD), a temporal bone defect between the superior semicircular canal and middle cranial fossa. Objective: To determine the origin and quantitative stimulus-response properties of the click-evoked VOR. Methods: Three-dimensional, binocular eye movements evoked by air-conducted 100-microsecond clicks ( 110 dB normal hearing level, 145 dB sound pressure level, 2 Hz) were measured with dual-search coils in 11 healthy subjects and 19 patients with SCD confirmed by CT imaging. Thresholds were established by decrementing loudness from 110 dB to 70 dB in 10-dB steps. Eye rotation axis of click-evoked VOR computed by vector analysis was referenced to known semicircular canal planes. Response characteristics were investigated with regard to enhancement using trains of three to seven clicks with 1-millisecond interclick intervals, visual fixation, head orientation, click polarity, and stimulation frequency ( 2 to 15 Hz). Results: In subjects and SCD patients, click-evoked VOR comprised upward, contraversive-torsional eye rotations with onset latency of approximately 9 milliseconds. Its eye rotation axis aligned with the superior canal axis, suggesting activation of superior canal receptors. In subjects, the amplitude was less than 0.01 degrees, and the magnitude was less than 3 degrees/second; in SCD, the amplitude was up to 60 times larger at 0.66 degrees, and its magnitude was between 5 and 92 degrees/second, with a threshold 10 to 40 dB below normal ( 110 dB). The click-evoked VOR magnitude was enhanced approximately 2.5 times with trains of five clicks but was unaffected by head orientation, visual fixation, click polarity, and stimulation frequency up to 10 Hz; it was also present on the surface electro-oculogram. Conclusion: In superior canal dehiscence, clicks evoked a high-magnitude, low-threshold, 9-millisecond-latency vestibulo-ocular reflex that aligns with the superior canal, suggesting superior canal receptor hypersensitivity to sound.
引用
收藏
页码:1079 / 1087
页数:9
相关论文
共 50 条
  • [21] Semicircular Canal Influences on the Developmental Tuning of the Translational Vestibulo-Ocular Reflex
    Branoner, Francisco
    Straka, Hans
    FRONTIERS IN NEUROLOGY, 2018, 9
  • [22] Posterior Semicircular Canal Dehiscence with Vestibulo-Ocular Reflex Reduction for the Affected Canal at the Video-Head Impulse Test: Considerations to Pathomechanisms
    Castellucci, Andrea
    Dumas, Georges
    Abuzaid, Sawsan M.
    Armato, Enrico
    Martellucci, Salvatore
    Malara, Pasquale
    Alfarghal, Mohamad
    Ruberto, Rosanna Rita
    Brizzi, Pasquale
    Ghidini, Angelo
    Comacchio, Francesco
    Schmerber, Sebastien
    AUDIOLOGY RESEARCH, 2024, 14 (02) : 317 - 332
  • [23] Effect of Spatial Orientation of the Horizontal Semicircular Canal on the Vestibulo-Ocular Reflex
    Maxwell, Rebecca
    von Kirschbaum, Constantin
    Jerin, Claudia
    Lehnen, Nadine
    Krause, Eike
    Guerkov, Robert
    OTOLOGY & NEUROTOLOGY, 2017, 38 (02) : 239 - 243
  • [24] Characterization of the vestibulo-ocular reflex evoked by high-velocity movements
    Roy, FD
    Tomlinson, RD
    LARYNGOSCOPE, 2004, 114 (07): : 1190 - 1193
  • [25] Sound-Evoked Responses in the Vestibulo-Ocular Reflex Pathways of Rats
    Chen, Tianwen
    Huang, Jun
    Yu, Yue
    Tang, Xuehui
    Zhang, Chunming
    Xu, Youguo
    Arteaga, Alberto
    Allison, Jerome
    Mustain, William
    Donald, Matthew C.
    Rappai, Tracy
    Zhang, Michael
    Zhou, Wu
    Zhu, Hong
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [26] Gentamicin vestibulotoxicity impairs human electrically evoked vestibulo-ocular reflex
    Aw, S. T.
    Todd, M. J.
    Aw, G. E.
    Weber, K. P.
    Halmagyi, G. M.
    NEUROLOGY, 2008, 71 (22) : 1776 - 1782
  • [27] The human translational vestibulo-ocular reflex in response to complex motion
    Walker, Mark
    Liao, Ke
    BASIC AND CLINICAL OCULAR MOTOR AND VESTIBULAR RESEARCH, 2011, 1233 : 242 - 248
  • [28] FREQUENCY-RESPONSE OF THE VESTIBULO-OCULAR REFLEX (VOR) IN THE MONKEY
    BUETTNER, UW
    HENN, V
    YOUNG, LR
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1981, 52 (02): : 73 - 77
  • [29] Ocular vestibular evoked myogenic potentials in superior canal dehiscence
    Rosengren, S. M.
    Aw, S. T.
    Halmagyi, G. M.
    Todd, N. P. McAngus
    Colebatch, J. G.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (05): : 559 - 566
  • [30] Influence of stimulus interval on the habituation of vestibulo-ocular reflex and sensation of rotation in humans
    Clement, Gilles
    Tilikete, Caroline
    Courjon, Jean-Hubert
    NEUROSCIENCE LETTERS, 2013, 549 : 40 - 44