Automatic acquisition of fiducial markers and alignment of images in tilt series for electron tomography

被引:61
|
作者
Ress, D [1 ]
Harlow, ML [1 ]
Schwarz, M [1 ]
Marshall, RM [1 ]
McMahan, UJ [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Neurobiol, Stanford, CA 94305 USA
来源
JOURNAL OF ELECTRON MICROSCOPY | 1999年 / 48卷 / 03期
关键词
electron microscopy; electron tomography; fine structure;
D O I
10.1093/oxfordjournals.jmicro.a023679
中图分类号
TH742 [显微镜];
学科分类号
摘要
Three-dimensional reconstruction of a section of biological tissue by electron tomography requires precise alignment of a series of two-dimensional images of the section made at numerous successive tilt angles. Gold beads on or in the section serve as fiducial markers. A scheme is described that automatically detects the position of these markers and indexes them from image to image. Time resulting set of position vectors are arranged in a matrix representation of the tilt geometry and, by inversion, alignment information is obtained. The scheme is convenient,, requires little operator time and provides an accuracy of <2 pixels RMS, A tilt series of 60-70 images can be aligned in similar to 30 min on any modern desktop computer.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 50 条
  • [41] Improvements on marker-free images alignment for electron tomography
    Sorzano, C. O. S.
    de Isidro-Gomez, F.
    Fernandez-Gimenez, E.
    Herreros, D.
    Marco, S.
    Carazo, J. M.
    Messaoudi, C.
    [J]. JOURNAL OF STRUCTURAL BIOLOGY-X, 2020, 4
  • [42] A template based technique for automatic detection of fiducial markers in 3D brain images
    Tan, Jun
    Chen, Dingguo
    Chaudhary, Vipin
    Sethi, Ishwar
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 47 - 49
  • [43] Alteration of magnification and image rotation in tilt series of electron microscopic images
    Zhang, HB
    Takaoka, A
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (01) : N3 - N6
  • [44] A deep learning framework for automatic detection of arbitrarily shaped fiducial markers in intrafraction fluoroscopic images
    Mylonas, Adam
    Keall, Paul J.
    Booth, Jeremy T.
    Shieh, Chun-Chien
    Eade, Thomas
    Poulsen, Per Rugaard
    Doan Trang Nguyen
    [J]. MEDICAL PHYSICS, 2019, 46 (05) : 2286 - 2297
  • [45] Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axis
    Díez, DC
    Seybert, A
    Frangakis, AS
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2006, 154 (02) : 195 - 205
  • [46] Markov random field based automatic image alignment for electron tomography
    Amat, Fernando
    Moussavi, Farshid
    Comolli, Luis R.
    Elidan, Gal
    Downing, Kenneth H.
    Horowitz, Mark
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2008, 161 (03) : 260 - 275
  • [47] Alternative automatic alignment method for specimen tilt-series images based on back-projected volume data cross-correlations
    Tomonaga, Sachihiko
    Baba, Misuzu
    Baba, Norio
    [J]. MICROSCOPY, 2014, 63 (04) : 279 - 294
  • [48] Registration free automatic identification of gold fiducial markers in MRI target delineation images for prostate radiotherapy
    Gustafsson, Christian
    Korhonen, Juha
    Persson, Emilia
    Gunnlaugsson, Adalsteinn
    Nyholm, Tufve
    Olsson, Lars E.
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 5563 - 5574
  • [49] Precise, Correlated Fluorescence Microscopy and Electron Tomography of Lowicryl Sections Using Fluorescent Fiducial Markers
    Kukulski, Wanda
    Schorb, Martin
    Welsch, Sonja
    Picco, Andrea
    Kaksonen, Marko
    Briggs, John A. G.
    [J]. CORRELATIVE LIGHT AND ELECTRON MICROSCOPY, 2012, 111 : 235 - 257
  • [50] Marker-free image registration of electron tomography tilt-series
    Sanchez Sorzano, Carlos Oscar
    Messaoudi, Cedric
    Eibauer, Matthias
    Bilbao-Castro, J. R.
    Hegerl, R.
    Nickell, S.
    Marco, S.
    Carazo, J. M.
    [J]. BMC BIOINFORMATICS, 2009, 10