Static Fourier transform imaging spectropolarimeter based on quarter-wave plate array

被引:5
|
作者
Quan, Naicheng [1 ]
Zhang, Chunmin [1 ]
Mu, Tingkui [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Sci, Inst Space Opt, 28 Xian Ning West Rd, Xian 710049, Shaanxi, Peoples R China
来源
OPTIK | 2016年 / 127卷 / 20期
基金
国家高技术研究发展计划(863计划); 高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Interference imaging spectropolarimeter; Birefringent beam splitter; Stokes paramters; SPECTRUM RECONSTRUCTION; SPECTROMETER; POLARIMETRY;
D O I
10.1016/j.ijleo.2016.07.058
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compact, static Fourier transform imaging spectropolarimeter based on quarter-wave plate array is conceptually described. It improves a Savart interferometer by replacing front polarizer with a Wollaston prism and an aperture divided by a quarter-wave plate array, and can simultaneously acquire six interferograms corresponding to six linearly polarized lights on a single CCD. The spectral dependence of all Stokes parameters can be recovered by Fourier transform. Since there is no rotating or moving part, the system is relatively robust. The interference model is proved. The performance of the system is demonstrated through a numerical simulation. The orientation of quarter-wave plate array is optimized. Alignment errors of the elements respect to the ideal position are discussed and a procedure for compensating the alignment errors is also developed. (C) 2016 Elsevier GmbH. All rights reserved.
引用
收藏
页码:9763 / 9774
页数:12
相关论文
共 50 条
  • [31] New method for retardance measurement of a quarter-wave plate
    Tan Q.
    Xu Q.
    Xie N.
    1600, Chinese Society of Astronautics (45):
  • [32] Tunable quarter-wave plate for determining light wavelength
    N. D. Kundikova
    A. M. Suvorova
    Technical Physics Letters, 2009, 35 : 63 - 66
  • [33] A Compact Broadband Terahertz Range Quarter-Wave Plate
    Wu, Liang
    Farid, A.
    Laurita, N. J.
    Mueller, T.
    Armitage, N. P.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2020, 41 (06) : 642 - 654
  • [34] WAVELENGTH DEPENDENCE OF THE PHASE RETARDATION OF A QUARTER-WAVE PLATE
    DENICOLA, S
    FERRARO, P
    FINIZIO, A
    PIERATTINI, G
    APPLIED PHYSICS B-LASERS AND OPTICS, 1995, 60 (04): : 405 - 407
  • [35] Tunable quarter-wave plate for determining light wavelength
    Kundikova, N. D.
    Suvorova, A. M.
    TECHNICAL PHYSICS LETTERS, 2009, 35 (01) : 63 - 66
  • [36] Measurement of Stokes parameters by quarter-wave plate and polarizer
    Kihara, T.
    Advances in Experimental Mechanics IV, 2005, 3-4 : 235 - 240
  • [37] QUARTER-WAVE PLATE TUNABLE IN A WIDE WAVELENGTH RANGE
    GOLTSER, IV
    DARSHT, MY
    ZELDOVICH, BY
    KUNDIKOVA, ND
    ROGACHEVA, LF
    KVANTOVAYA ELEKTRONIKA, 1995, 22 (02): : 201 - 204
  • [38] Broadband infrared meanderline reflective quarter-wave plate
    Wadsworth, Samuel L.
    Boreman, Glenn D.
    OPTICS EXPRESS, 2011, 19 (11): : 10604 - 10612
  • [39] Achromatic quarter-wave plate using crystalline quartz
    Saha, Arijit
    Bhattacharya, Kallol
    Chakraborty, Ajoy Kumar
    APPLIED OPTICS, 2012, 51 (12) : 1976 - 1980
  • [40] Novel method for measurement of retardance of a quarter-wave plate
    Wang, ZP
    Li, QB
    Tan, Q
    Huang, ZJ
    Shi, JH
    OPTICS AND LASER TECHNOLOGY, 2004, 36 (04): : 285 - 290