Static Fourier transform imaging spectropolarimeter based on quarter-wave plate array

被引:5
|
作者
Quan, Naicheng [1 ]
Zhang, Chunmin [1 ]
Mu, Tingkui [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Sci, Inst Space Opt, 28 Xian Ning West Rd, Xian 710049, Shaanxi, Peoples R China
来源
OPTIK | 2016年 / 127卷 / 20期
基金
国家高技术研究发展计划(863计划); 高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Interference imaging spectropolarimeter; Birefringent beam splitter; Stokes paramters; SPECTRUM RECONSTRUCTION; SPECTROMETER; POLARIMETRY;
D O I
10.1016/j.ijleo.2016.07.058
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compact, static Fourier transform imaging spectropolarimeter based on quarter-wave plate array is conceptually described. It improves a Savart interferometer by replacing front polarizer with a Wollaston prism and an aperture divided by a quarter-wave plate array, and can simultaneously acquire six interferograms corresponding to six linearly polarized lights on a single CCD. The spectral dependence of all Stokes parameters can be recovered by Fourier transform. Since there is no rotating or moving part, the system is relatively robust. The interference model is proved. The performance of the system is demonstrated through a numerical simulation. The orientation of quarter-wave plate array is optimized. Alignment errors of the elements respect to the ideal position are discussed and a procedure for compensating the alignment errors is also developed. (C) 2016 Elsevier GmbH. All rights reserved.
引用
收藏
页码:9763 / 9774
页数:12
相关论文
共 50 条
  • [1] Quarter-wave plate in a Fourier spectrometer
    Moshkin, B. E.
    Maksimenko, S. V.
    Shakun, A. V.
    JOURNAL OF OPTICAL TECHNOLOGY, 2011, 78 (06) : 386 - 388
  • [2] Compact static Fourier transform imaging spectropolarimeter based on channeled polarimetry
    Li, Jie
    Zhu, Jingping
    Wu, Haiying
    OPTICS LETTERS, 2010, 35 (22) : 3784 - 3786
  • [3] Multichannel vortex beam array based on quarter-wave plate metasurface
    Song, Yixing
    Zheng, Kaiyuan
    Zeng, Yong
    Sun, Xiaohong
    OPTICAL ENGINEERING, 2024, 63 (10)
  • [4] Tests of a compact static Fourier-transform imaging spectropolarimeter
    Li, Jie
    Gao, Bo
    Qi, Chun
    Zhu, Jingping
    Hou, Xun
    OPTICS EXPRESS, 2014, 22 (11): : 13014 - 13021
  • [5] AN ADJUSTABLE QUARTER-WAVE PLATE
    GOLTSER, IV
    DARSCHT, MY
    KUNDIKOVA, ND
    ZELDOVICH, BY
    OPTICS COMMUNICATIONS, 1993, 97 (5-6) : 291 - 294
  • [6] Plasmonic quarter-wave plate
    Roberts, A.
    Lin, L.
    OPTICS LETTERS, 2012, 37 (11) : 1820 - 1822
  • [7] Design and performance of a compact, miniature static Fourier transform imaging spectropolarimeter
    Li Jie
    Zhu Jing-ping
    Wu Hai-ying
    Hou Xun
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: SENSOR AND MICROMACHINED OPTICAL DEVICE TECHNOLOGIES, 2011, 8191
  • [8] Photoelastic stress pattern analysis using Fourier transform with carrier fringes: influence of quarter-wave plate error
    Zuccarello, B
    Tripoli, G
    OPTICS AND LASERS IN ENGINEERING, 2002, 37 (04) : 401 - 416
  • [9] THE THEORY OF THE COMPOSITE QUARTER-WAVE PLATE
    ABEN, KK
    OPTIKA I SPEKTROSKOPIYA, 1962, 13 (05): : 746 - 750
  • [10] Terahertz achromatic quarter-wave plate
    Masson, JB
    Gallot, G
    OPTICS LETTERS, 2006, 31 (02) : 265 - 267