[1] EFfat Univ, Dept Elect & Comp Engn, Jeddah 21478, Saudi Arabia
关键词
electrocardiography; medical signal processing; filtering theory; power-line interference elimination; ECG signals; electrocardiogram signals; signal variations; inferior order filters; MIT-BIH ECG database; signal-to-noise ratio; 2.18-fold compression gain; computational efficiency; analogous output SNR; baseline wander interference elimination; signal-piloted linear phase filtering tactics; eigenvalue decomposition based tactics; REMOVAL;
D O I
10.1049/htl.2019.0116
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A signal-piloted linear phase filtering tactic for removing baseline wander and power-line interference from the electrocardiogram (ECG) signals is suggested. The system is capable of adjusting its parameters by following the incoming signal variations. It renders the processing of lesser samples by inferior order filters. The applicability is demonstrated by using the MIT-BIH ECG database. The precision of the approach is also studied regarding the signal-to-noise ratio (SNR). Results showed that the proposed method achieves a 2.18-fold compression gain and notable computational efficiency over conventional counterpart while securing an analogous output SNR. A comparison of the designed solution is made with the contemporary empirical mode decomposition with Kalman filtering and eigenvalue decomposition based tactics. Results show that the suggested method performs better in terms of output SNR for the studied cases.
引用
收藏
页码:114 / 118
页数:5
相关论文
共 50 条
  • [21] A wavelet-based method for power-line interference removal in ECG signals
    de Oliveira B.R.
    Duarte M.A.Q.
    de Abreu C.C.E.
    Filho J.V.
    Research on Biomedical Engineering, 2018, 34 (01) : 73 - 86
  • [22] Testing of digital filters for power-line interference removal from ECG signals
    Mihov, Georgy Slavchev
    Badarov, Dimiter Hristov
    2017 XXVI INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS (ET), 2017,
  • [23] Elimination of Power Line Interference from ECG Signals Using Recurrent Neural Networks
    Qiu, Yue
    Xiao, Feng
    Shen, Haibin
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2296 - 2299
  • [24] Power-line interference elimination from ECG in case of non-multiplicity between the sampling rate and the power-line frequency
    Mihov, Georgy
    Dotsinsky, Ivan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2008, 3 (04) : 334 - 340
  • [25] A nonlinear adaptive method of elimination of power line interference in ECG signals
    Ziarani, AK
    Konrad, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (06) : 540 - 547
  • [26] Suppression of power-line interference by analog notch filtering in the ECG signal for heart rate variability analysis: to do or not to do?
    Hejjel, L
    MEDICAL SCIENCE MONITOR, 2004, 10 (01): : MT6 - MT13
  • [27] Power-Line Interference Removal from High Sampled Ecg Signals Using Modified Version of the Subtraction Procedure
    Dotsinsky I.
    Stoyanov T.
    Mihov G.
    International Journal Bioautomation, 2020, 24 : 381 - 392
  • [28] Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators
    Ivan Dotsinsky
    BioMedical Engineering OnLine, 4
  • [29] A Power-Line Interference Canceler Based on Sliding DFT Phase Locking Scheme for ECG Signals
    Mishra, Sarita
    Das, Debasmit
    Kumar, Roshan
    Sumathi, Parasuraman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (01) : 132 - 142
  • [30] Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators
    Dotsinsky, Ivan
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)