Development of a Computerized 4-D MRI Phantom for Liver Motion Study

被引:6
|
作者
Wang, Chunhao [1 ]
Yin, Fang-Fang [1 ,2 ]
Segars, W. P. [3 ]
Chang, Zheng [1 ]
Ren, Lei [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Jiangsu, Peoples R China
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
MRI; computerized phantom; liver; organ motion; deformable registration; PHARMACOKINETIC ANALYSIS; ORGAN MOTION; XCAT; SIMULATION; THERAPY; HEAD;
D O I
10.1177/1533034617723753
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. Methods: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal-chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. Results: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal-chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 0.11 cm(3) in a respiratory cycle and the tumor's maximum center-of-mass shift was 2.95 cm/1.84 cm on superior-inferior/anterior-posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. Conclusions: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 50 条
  • [1] Development of a Computerized 4D MRI Phantom for Liver Motion Study
    Wang, C.
    Yin, F.
    Segars, P.
    Chang, Z.
    Ren, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3027 - 3027
  • [2] Quantitative evaluation of a new 4D MRI sequence: a motion phantom study
    Parent, L.
    Nemtanu, T.
    Celicanin, Z.
    Bieri, O.
    Cattin, P.
    Ken, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1210 - S1210
  • [3] Development of a 4-D digital mouse phantom for molecular imaging research
    Segars, WP
    Tsui, BMW
    Frey, EC
    Johnson, GA
    Berr, SS
    MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (03) : 149 - 159
  • [4] Combined effects of respiratory motion and object size on 3-D and 4-D PET/CT images: Dynamic phantom study
    Park, S.
    Ionascu, D.
    Killoran, J.
    Mamede, M.
    Thomas, S.
    Gerbaudo, V.
    Chin, L.
    Berbeco, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2571 - 2571
  • [5] Development of a 3D Printed Motion Mechanism for a 4D Respiratory Motion Phantom
    Ahmad, Muhammad Akmal
    Mustaza, Seri Mastura
    Mokri, Siti Salasiah
    Azmi, Nor Aniza
    Ahmad, Rozilawati
    Ramli, Rizauddin
    Rahman, Wan Nordiana Wan Abdul
    Abd Rahni, Ashrani Aizzuddin
    2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, : 132 - 135
  • [6] Motion modeling from 4D MR images of liver simulating phantom
    Kavaluus, Henna
    Koivula, Lauri
    Salli, Eero
    Seppala, Tiina
    Saarilahti, Kauko
    Tenhunen, Mikko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [7] Phantom-Based Evaluation of Isotropic Reconstruction of 4-D MRI Volumes using Super-Resolution
    Van Reeth, Eric
    Tham, Ivan W. K.
    Tan, Cher Heng
    Poh, Chueh Loo
    PROCEEDINGS OF THE 2013 FOURTH INTERNATIONAL WORKSHOP ON COMPUTATIONAL INTELLIGENCE IN MEDICAL IMAGING (CIMI), 2013, : 6 - 13
  • [8] 4-D MRI for Cord Motion at the Cervico-Dorsal Curvature: Implications for Spinal SBRT
    Salvi, S. S.
    Shankar, V.
    Haritha, C.
    Raut, N.
    Kendre, P. P.
    Chauhan, B.
    Bhaskar, P.
    Basu, T.
    Bhange, A.
    Saxena, U.
    Maurya, S.
    Sen, D.
    Lohith, G. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S149 - S149
  • [9] Development of the 4D Phantom Using the 3D Gel Dosimetry for Liver SBRT: A Preliminary Study
    Noh, S.
    Lee, M.
    Yoon, K.
    Kwak, J.
    Cho, B.
    Kim, S.
    Kim, H.
    Jeong, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E326 - E327
  • [10] New 4-D imaging for real-time intraoperative MRI: Adaptive 4-D scan
    Tokuda, Junichi
    Morikawa, Shigehiro
    Haque, Hasnine A.
    Tsukamoto, Tetsuji
    Matsumiya, Kiyoshi
    Liao, Hongen
    Masamune, Ken
    Dohi, Takeyoshi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 454 - 461