Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization as a Technique for the Characterization of Salt-Containing Organic Samples

被引:9
|
作者
Alves, Michael R. [2 ]
Sauer, Jon S. [2 ]
Prather, Kimberly A. [2 ,3 ]
Grassian, Vicki H. [2 ,4 ,5 ]
Wilkins, Charles L. [1 ]
机构
[1] Univ Arkansas, Dept Chem & Biochem, Fayetteville, AR 72701 USA
[2] Univ Calif San Diego, Dept Chem & Biochem, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Scripps Inst Oceanog, La Jolla, CA 92037 USA
[4] Univ Calif San Diego, Scripps Inst Oceanog, Dept Chem & Biochem, La Jolla, CA 92037 USA
[5] Univ Calif San Diego, Dept Nanoengn, La Jolla, CA 92093 USA
基金
美国国家科学基金会;
关键词
SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; ELECTROSPRAY; MATTER; ULTRAFILTRATION; IDENTIFICATION; CHROMATOGRAPHY; BIOMOLECULES; FORMULAS; FIGURES;
D O I
10.1021/acs.analchem.0c00361
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Typical ionization techniques used for mass spectrometry (MS) analysis face challenges when trying to analyze organic species in a high-salt environment. Here, we present results using a recently developed ionization source, liquid sampling-atmospheric pressure glow discharge (LS-APGD), for marine-relevant salt-containing organic samples. Using two representative sample types, a triglyceride mixture and dissolved organic matter, this method is compared to traditional electrospray ionization (ESI) under saline and neat conditions. LS-APGD produced equal or higher (15%+) ion intensities than those of ESI for both salt-containing and neat samples, although important differences linked with adduct formation in high-salt conditions explain the molecular species observed. For all sample types, LS-APGD observed a higher diversity of molecules under optimized settings (0.25 mm electrode spacing at 20 mA) compared to traditional ESI. Furthermore, because the LS-APGD source ionizes molecular species in a similar to 1 mm(3) volume plasma using a low-power source, there is the potential for this method to be applied in field studies, eliminating desalting procedures, which can be time-consuming and nonideal for low-concentration species.
引用
收藏
页码:8845 / 8851
页数:7
相关论文
共 50 条
  • [41] Liquid Sampling-Atmospheric Pressure Glow Discharge as a Secondary Excitation Source for Laser Ablation-Generated Aerosols: Parametric Dependence and Robustness to Particle Loading
    Manard, Benjamin T.
    Konegger-Kappel, Stefanie
    Gonzalez, Jhanis J.
    Chirinos, Jose
    Dong, Meirong
    Mao, Xianglei
    Marcus, R. Kenneth
    Russo, Richard E.
    APPLIED SPECTROSCOPY, 2015, 69 (01) : 58 - 66
  • [42] Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications
    Hoegg, Edward D.
    Manard, Benjamin T.
    Wylie, E. Miller
    Mathew, K. J.
    Ottenfeld, Chelsea F.
    Marcus, R. Kenneth
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (02) : 278 - 288
  • [43] Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer
    Hoegg, Edward D.
    Barinaga, Charles J.
    Hager, George J.
    Hart, Garret L.
    Koppenaal, David W.
    Marcus, R. Kenneth
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (12) : 2355 - 2362
  • [44] An atmospheric pressure glow discharge optical emission source for the direct sampling of liquid media
    Davis, WC
    Marcus, RK
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) : 931 - 937
  • [45] An atmospheric pressure glow discharge optical emission source for the direct sampling of liquid media
    Davis, W.C.
    Marcus, R.K.
    1600, Royal Society of Chemistry (16):
  • [46] An atmospheric pressure glow discharge optical emission source for the direct sampling of liquid media
    Marcus, RK
    Davis, WC
    ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2903 - 2910
  • [47] Improved Uranium Isotope Ratio Analysis in Liquid Sampling-Atmospheric Pressure Glow Discharge/Orbitrap FTMS Coupling through the Use of an External Data Acquisition System
    Bills, Jacob R.
    Nagornov, Konstantin O.
    Kozhinov, Anton N.
    Williams, Tyler J.
    Tsybin, Yury O.
    Marcus, R. Kenneth
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (05) : 1224 - 1236
  • [48] Roles of collisional dissociation modalities on spectral composition and isotope ratio measurement performance of the liquid sampling-atmospheric pressure glow discharge/orbitrap mass spectrometer coupling
    Williams, Tyler J.
    Hoegg, Edward D.
    Bills, Jacob R.
    Marcus, R. Kenneth
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 464
  • [49] Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling-atmospheric pressure glow discharge-orbitrap mass spectrometer system
    Goodwin, Joseph V.
    Manard, Benjamin T.
    Ticknor, Brian W.
    Rogers, Kayron T.
    Hexel, Cole R.
    Cable-Dunlap, Paula
    Marcus, R. Kenneth
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (7) : 2875 - 2886
  • [50] Ambient desorption/ionization mass spectrometry using a liquid sampling–atmospheric glow discharge (LS-APGD) ionization source
    R. Kenneth Marcus
    Carolyn Q. Burdette
    Benjamin T. Manard
    Lynn X. Zhang
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8171 - 8184