Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study

被引:7
|
作者
Cheema, Gursimrat Singh [1 ]
Rastogi, Amit [2 ]
Singh, Vakil [3 ]
Goel, Satish Chandra [2 ]
Mishra, Diwakar [1 ]
Arora, Sumit [1 ]
机构
[1] Maulana Azad Med Coll & Associated Lok Nayak Hosp, Dept Orthopaed Surg, New Delhi, India
[2] Banaras Hindu Univ, Inst Med Sci, Dept Orthopaed, Varanasi 221005, Uttar Pradesh, India
[3] Banaras Hindu Univ, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
Dynamic condylar screw; proximal femoral nailing; reverse oblique trochanteric fractures; INTERTROCHANTERIC HIP-FRACTURES; GAMMA-NAIL; FIXATION; FEMUR; DHS; INTRAMEDULLARY; PLATE;
D O I
10.4103/0019-5413.96369
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reverse oblique trochanteric fracture of femur is a distinct fracture pattern. 95 Dynamic condylar screw (DCS) and proximal femoral nail (PFN) are currently the most commonly used implants for its fixation. This study aims to biomechanically compare the cutout resistance as well as modes of failure of DCS and PFN in reverse oblique trochanteric fractures. Materials and Methods: Sixteen freshly harvested cadaveric proximal femoral specimens were randomly assigned to three mean bone mineral density matched groups, eight of which were implanted with 95 DCS and the other eight with PFN. The constructs were made unstable to resemble a reverse oblique trochanteric fracture by removing a standard size posteromedial wedge. These constructs were subjected to computer controlled cyclic compressive loading with 200 kg at a frequency of 1 cycle/second (1 Hz) and end points of both the groups were analyzed. Results: The bending moment of the PFN group was approximately 50% less than that of the DCS group (P<0.0001). The PFN group resisted more number of cycles than the DCS group (P=0.03) and showed lesser number of component failures as compared with the DCS group (P=0.003). Conclusions: The PFN is biomechanically superior to DCS for the fixation of reverse oblique trochanteric fractures of femur.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
  • [31] A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures
    Huang, Yanfeng
    Zhang, Chunlin
    Luo, Yi
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2465 - 2473
  • [32] Trochanteric gamma nail vs proximal femoral nail for pertrochanteric fractures: A comparative study
    Megas, P
    Kaisidis, A
    Zouboulis, P
    Papas, M
    Panagopoulos, A
    Lambiris, E
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (02): : 252 - 257
  • [33] Subtrochanteric femoral fractures: a comparative study of the long proximal femoral nail and the long trochanteric fixation nail
    E. Muñoz-Mahamud
    E. García-Oltra
    J. A. Fernández-Valencia
    J. A. Zumbado
    J. Ríos
    S. Suso
    G. Bori
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 511 - 516
  • [34] Subtrochanteric femoral fractures: a comparative study of the long proximal femoral nail and the long trochanteric fixation nail
    Munoz-Mahamud, E.
    Garcia-Oltra, E.
    Fernandez-Valencia, J. A.
    Zumbado, J. A.
    Rios, J.
    Suso, S.
    Bori, G.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (07): : 511 - 516
  • [35] A COMPARATIVE STUDY OF FUNCTIONAL OUTCOME BETWEEN DYNAMIC HIP SCREW AND PROXIMAL FEMORAL NAIL IN SURGICAL MANAGEMENT OF PER-TROCHANTERIC FRACTURES
    Shivanna, Umesh M.
    Rudrappa, Girish H.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (43): : 7489 - 7498
  • [36] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Singh, Ashutosh Kumar
    Rastogi, Amit
    Singh, Vakil
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (06) : 615 - 620
  • [37] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Ashutosh Kumar Singh
    Amit Rastogi
    Vakil Singh
    Indian Journal of Orthopaedics, 2013, 47 : 615 - 620
  • [38] Comparison between Proximal Femoral Nail Antirotation (PFNA) and Dynamic Condylar Screw (DCS) in the Management of Unstable Proximal Femur Fractures in Term of Mean Union Time
    Akhtar, Muhammad Saleem
    Gillani, Haroon Ur Rehman
    Khan, Kashif Raza
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 555 - 558
  • [39] Dynamic Condylar Screw (DCS) versus Condylar Blade Plate (CBP) in Complex Supracondylar Femoral Fractures - A Biomechanical Study
    Sirbu, P. D.
    Carata, E.
    Petreus, T.
    Munteanu, F.
    Popescu, C.
    Asaftei, R.
    Botez, P.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 409 - +
  • [40] Stabilisation of unstable trochanteric femoral fractures.: Dynamic hip screw (DHS) with trochanteric stabilisation plate vs. proximal femur nail (PFN)
    Nuber, S
    Schönweiss, T
    Rüter, A
    UNFALLCHIRURG, 2003, 106 (01): : 39 - 47