Research on Line Selection Method of Single-phase Earth Fault Based on Improved Dynamic Time Bending Distance Similarity Word

被引:0
|
作者
Huo, Min [1 ]
Fu, Zhouxing [1 ]
Zhang, Junming [2 ]
机构
[1] Xian Univ Sci & Technol, Sch Elect & Control Engn, Xian 710054, Shaanxi, Peoples R China
[2] State Grid Yulin Power Supply Co, Operat & Maintenance Dept, Yulin 719000, Shaanxi, Peoples R China
关键词
D O I
10.1088/1755-1315/461/1/012051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The problem of fault line selection for the distribution network of neutral point via arc suppression coil grounding has not been solved for a long time. Based on this, a single-phase ground fault line selection method based on dynamic time bending distance similarity is proposed. Firstly, the single-phase ground fault feature analysis of the distribution network of the zero-mode network is used to determine the electrical characteristic quantity of the single-phase ground fault line selection. Then, the faulty electrical feature quantity is improved by the dynamic time bending distance algorithm to form the distance matrix. The similarity data processing is performed on the matrix to obtain a line selection vector, and then the fault line is selected. Finally, the single-phase ground fault system model of 10kV distribution network is constructed by Matlab/Simulink. The correctness and feasibility of single-phase ground fault line selection method based on the dynamic time bending distance similarity is verified by simulation under different fault conditions.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Wireless communication based single-phase earth fault location in distribution network and its dynamic simulation experiment
    Wang, Chen
    Wu, Junyong
    Tuersun, Yiming
    Chen, Zhanfeng
    Wu, Zhilin
    He, Lihan
    Dianwang Jishu/Power System Technology, 2014, 38 (08): : 2280 - 2285
  • [42] Single-phase-to-ground fault line selection in distribution networks based on similarity of wavelet energy spectrum
    Qi, Mingjun
    Zhong, Qiang
    Zhu, Liang
    Gong, Fangliang
    Leng, Hua
    PROCEEDINGS OF THE 2015 5TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCES AND AUTOMATION ENGINEERING, 2016, 42 : 338 - 343
  • [43] Fault Line Selection Principle of Single-phase-to-ground Fault Based on Improved Zero-sequence Admittance
    Luan X.
    Wu S.
    Jia C.
    Yang Y.
    Zhang Z.
    Luo X.
    Dianwang Jishu/Power System Technology, 2022, 46 (01): : 353 - 360
  • [44] Development of Single-Phase Earth Fault Location Algorithms Using Cable Line Simulation Models
    Shuin, V
    Filatova, G.
    Vorobeva, E.
    2018 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2018,
  • [45] Phase selection method of single line to ground fault in unbalanced distribution network based on ground fault ratio
    Sun Z.
    Xu H.
    Zhu H.
    Bian C.
    Yu D.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (12): : 108 - 116
  • [46] Technology of fault line selection for single-phase-to-earth fault in small current grounding system
    Li, Bo
    NONLINEAR DYNAMICS, 2012, 67 (03) : 2111 - 2122
  • [47] Technology of fault line selection for single-phase-to-earth fault in small current grounding system
    Bo Li
    Nonlinear Dynamics, 2012, 67 : 2111 - 2122
  • [48] Research on Fault Detection Method Based on Improved Euclidean Distance Control
    Liu, Xiaoqiang
    Li, Fei
    2022 IEEE 17TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2022, : 106 - 111
  • [49] A Single-phase Earth Fault Location Method Based on Transient Energy for Non-effectively Grounded System
    Wang X.
    Shi F.
    Zhang H.
    Xue J.
    Yun Z.
    Xie W.
    Ling P.
    Liu J.
    Dianwang Jishu/Power System Technology, 2019, 43 (03): : 818 - 825
  • [50] Single-phase earth fault protection method based on combined voltage criterion in high voltage shunt capacitor
    Ma W.
    Kong S.
    Liu C.
    Song C.
    Liu Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (22): : 142 - 147