Heparin therapy leads to platelet activation and prolongation of PFA-100 closure time

被引:13
|
作者
Williams, MS [1 ]
Ng'alla, LS [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Med, Baltimore, MD 21205 USA
关键词
platelet function; heparin; PFA testing;
D O I
10.1177/107424840501000407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Heparin is used in the treatment of venous and arterial thromboembolic events, including unstable angina. Once Unfractionated heparin is discontinued during the acute phase of unstable angina, it has been demonstrated that the disease process may be reactivated within hours. It is hypothesized that this reactivation may be a result of direct platelet activation by heparin that can linger even after the drug itself has been stopped. Prior studies C have shown that heparin can either increase or decrease platelet activation. More recent Studies have also shown conflicting effects of unfractionated heparin on PFA-100 testing. Methods: We studied the in-vitro effects of unfractionated heparin on platelet function and PFA-100 testing. Unfractionated heparin was incubated with whole blood taken from 18 health), volunteers. Platelet activation and aggregation was assessed with and without the presence of heparin. Results: Platelet aggregation and activation were increased in the presence of heparin. Unfractionated heparin also significantly prolonged collagen/adenosine diphosphate closure time but did not affect collagen/epinephrine closure time. Conclusions: Unfractionated heparin leads to direct platelet activation and increases platelet aggregation in vitro. Unfractionated heparin causes prolongation of the collagen/adenosine diphosphate closure time in PFA-100 testing, possibly as a result of direct binding to von Willebrand factor in solution and interference with von Willebrand factor-glycoprotein Ib binding.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 50 条
  • [21] Diurnal variation in platelet aggregation with the PFA-100 platelet function analyser
    Dalby, MCD
    Davidson, SJ
    Burman, JF
    Davies, SW
    PLATELETS, 2000, 11 (06) : 320 - 324
  • [22] Detection of platelet hypofunction in clinical practice: Comparison of PFA-100 with bleeding time.
    Posan, E
    Nichols, WL
    McBane, RD
    Diane, GE
    Motsko, CL
    BLOOD, 2001, 98 (11) : 250A - 250A
  • [23] Time lag in platelet function inhibition by clopidogrel in stroke patients as measured by PFA-100
    Raman, S
    Reiter, R
    Jilma, B
    PHARMACOLOGY, 2004, 72 (02) : 138 - 138
  • [24] Evaluation of platelet function in von Willebrand disease with PFA-100®
    Cattaneo, M
    Federici, AB
    Agati, B
    Lecchi, A
    Stabile, F
    Lombardi, R
    Canciani, MT
    Mannucci, PM
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 368 - 368
  • [25] The influence of citrate concentrations on PFA-100 closure times, platelet hyper-reactivity and aspirin monitoring
    Harrison, Paul
    THROMBOSIS RESEARCH, 2010, 126 (02) : E137 - E138
  • [26] Evaluation of platelet function in von Willebrand disease with PFA-100®
    Agati, B
    Cattaneo, M
    Federici, AB
    Lecchi, A
    Stabile, F
    Lombardi, R
    Canciani, MT
    Mannucci, PM
    THROMBOSIS RESEARCH, 1998, 91 (03) : S19 - S19
  • [27] Use of the platelet function analyser PFA-100™ in juvenile pigs
    Constanze Leuser
    Sibylle Schlottmann
    Ralf Siekmann
    Martin Heidt
    Andreas Moritz
    Natali Bauer
    Comparative Clinical Pathology, 2012, 21 (5) : 761 - 767
  • [28] Evaluation of platelet function in diabetic patients using the PFA-100™.
    Dwyre, DM
    Rios, D
    Wun, T
    Janatpour, KA
    Gosselin, R
    Larkin, EC
    BLOOD, 2001, 98 (11) : 59B - 59B
  • [29] Platelet function during pregnancy : An evaluation with PFA-100 analyzer
    Nathan, N
    Vincelot, A
    Julia, A
    Collet, D
    Grandchamp, P
    ANESTHESIOLOGY, 2000, 93 (3A) : U215 - U215
  • [30] Time lag in platelet function inhibition by clopidogrel in stroke patients as measured by PFA-100
    Raman, S
    Jilma, B
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2004, 2 (12) : 2278 - 2279