Quadrupole-Linear Ion Trap Tandem Mass Spectrometry System for Clinical Biomarker Analysis

被引:9
|
作者
Fang, Xiang [1 ]
Xie, Jie [1 ]
Chu, Shiying [1 ]
Jiang, You [1 ]
An, Yuting [1 ,2 ]
Li, Chang [1 ,2 ]
Gong, Xiaoyun [1 ]
Zhai, Rui [1 ]
Huang, Zejian [1 ]
Qiu, Chunling [2 ]
Dai, Xinhua [1 ]
机构
[1] Natl Inst Metrol, Ctr Adv Measurement Sci, Technol Innovat Ctr Mass Spectrometry State Market, Beijing 100029, Peoples R China
[2] Jilin Univ, Coll Instrument Sci & Elect Engn, Changchun 130026, Peoples R China
来源
ENGINEERING | 2022年 / 16卷
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Linear ion trap; Quadrupole; Space charge effect; Collision-induced dissociation; Biomarker; FLOW-INJECTION ANALYSIS; CREATINE; GUANIDINOACETATE; DEFICIENCY; INTERFACE; NEWBORN; MARKERS; DESIGN; MS/MS;
D O I
10.1016/j.eng.2020.10.021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The accurate and efficient measurement of small molecule disease markers for clinical diagnosis is of great importance. In this study, a quadrupole-linear ion trap (Q-LIT) tandem mass spectrometer was designed and built in our laboratory. Target precursor ions were first selected in the quadrupole, and then injected, trapped, and fragmented simultaneously in the linear ion trap (LIT) to reduce the space charge effect, enrich the target product ions, and promote sensitivity. The targeted analytes were measured with selected reaction monitoring using a positive scan mode with electrospray ionization (ESI). Ions with a mass-to-charge ratio (m/z) ranging from 195 to 2022 were demonstrated. When scanning at 1218 amu.s(-1), unit resolution and an accuracy of higher than m/z 0.28 was obtained for m/z up to 2000. The dimensionless Mathieu parameter (q) value used in this study was 0.40 for collision-induced dissociation (CID), which was activated by resonance excitation. And an overall CID efficiency of 64% was achieved (activation time, 50 ms). Guanidinoacetic acid (GAA) and creatine (CRE) were used as model compounds for small molecule clinical biomarkers. The limits of quantification were 1.0 and 0.2 nmol.L-1 for GAA and CRE, respectively. A total of 77 actual samples were successfully analyzed by the home-built ESI-Q-LIT tandem mass spectrometry system. The developed method can reduce matrix interference, minimize space charge effects, and avoid the chromatographic separation of complex samples to simplify the pre-treatment process. This novel Q-LIT system is expected to be a good candidate for the determination of biomarkers in clinical diagnosis and therapeutics. (C) 2022 THE AUTHORS. Published by Elsevier LTD on behalf of Chinese Academy of Engineering and Higher Education Press Limited Company.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 50 条
  • [41] Metabolic characterization of (±)-praeruptorin A in vitro and in vivo by high performance liquid chromatography coupled with hybrid triple quadrupole-linear ion trap mass spectrometry and time-of-flight mass spectrometry
    Song, Yue-Lin
    Jing, Wang-Hui
    Yan, Ru
    Wang, Yi-Tao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 : 98 - 110
  • [42] Rapid analysis of multiclass antibiotic residues and some of their metabolites in hospital, urban wastewater and river water by ultra-high-performance liquid chromatography coupled to quadrupole-linear ion trap tandem mass spectrometry
    Gros, Meritxell
    Rodriguez-Mozaz, Sara
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1292 : 173 - 188
  • [43] Metabolite Profile of Salidroside in Rats by Ultraperformance Liquid Chromatography Coupled with Quadrupole Time-of-Flight Mass Spectrometry and High-Performance Liquid Chromatography Coupled with Quadrupole-Linear Ion Trap Mass Spectrometry
    Hu, Zhiwei
    Wang, Ziming
    Liu, Yong
    Wu, Yan
    Han, Xuejiao
    Zheng, Jian
    Yan, Xiufeng
    Wang, Yang
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (41) : 8999 - 9005
  • [44] Effects of fragile ions on mass resolution and on isolation for tandem mass spectrometry in the quadrupole ion trap mass spectrometer
    McClellan, JE
    Murphy, JP
    Mulholland, JJ
    Yost, RA
    ANALYTICAL CHEMISTRY, 2002, 74 (02) : 402 - 412
  • [45] FIXED-WAVELENGTH LASER IONIZATION TANDEM MASS-SPECTROMETRY FOR MIXTURE ANALYSIS IN THE QUADRUPOLE ION TRAP
    GOERINGER, DE
    GLISH, GL
    MCLUCKEY, SA
    ANALYTICAL CHEMISTRY, 1991, 63 (13) : 1186 - 1192
  • [46] Systematic Qualitative and Quantitative Analyses of Wenxin Granule via Ultra-High Performance Liquid Chromatography Coupled with Ion Mobility Quadrupole Time-of-Flight Mass Spectrometry and Triple Quadrupole-Linear Ion Trap Mass Spectrometry
    Mi, Yueguang
    Hu, Wandi
    Li, Weiwei
    Wan, Shiyu
    Xu, Xiaoyan
    Liu, Meiyu
    Wang, Hongda
    Mei, Quanxi
    Chen, Qinhua
    Yang, Yang
    Chen, Boxue
    Jiang, Meiting
    Li, Xue
    Yang, Wenzhi
    Guo, Dean
    MOLECULES, 2022, 27 (11):
  • [47] Characterization of xylazine metabolism in rat liver microsomes using liquid chromatography-hybrid triple quadrupole-linear ion trap-mass spectrometry
    Lavoie, David St-Germain
    Pailleux, Floriane
    Vachon, Pascal
    Beaudry, Francis
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (07) : 882 - 888
  • [48] QUADRUPOLE ION TRAP MASS-SPECTROMETRY OF FULLERENES
    MORAND, KL
    HOKE, SH
    EBERLIN, MN
    PAYNE, G
    COOKS, RG
    ORGANIC MASS SPECTROMETRY, 1992, 27 (03): : 284 - 288
  • [49] Characterization of sodiated lipids by electrospray ionization-quadrupole ion trap tandem mass spectrometry
    Ho, YP
    Huang, PC
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (05) : 751 - 756
  • [50] Calibration of a quadrupole ion trap for particle mass spectrometry
    Trevitt, Adam J.
    Wearne, Philip J.
    Bieske, Evan J.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 262 (03) : 241 - 246