Electrokinetic remediation of heavy metal-contaminated soils: performance comparison between one- and two-dimensional electrode configurations

被引:35
|
作者
Kim, Soon-Oh [1 ,2 ]
Jeong, Jin Young [3 ]
Lee, Woo-Chun [1 ,2 ]
Yun, Seong-Taek [4 ,5 ]
Jo, Ho Young [4 ,5 ]
机构
[1] Gyeongsang Natl Univ GNU, Dept Geol, Jinju 52828, South Korea
[2] Gyeongsang Natl Univ GNU, Res Inst Nat Sci RINS, Jinju 52828, South Korea
[3] Korea Environm Corp, Dept Soil & Groundwater, Incheon 22689, South Korea
[4] Korea Univ, Dept Earth & Environm Sci, Seoul 02841, South Korea
[5] Korea Univ, SMART SEM Res Ctr, Seoul 02841, South Korea
关键词
Electrokinetic remediation; Electrode configuration; Heavy metals; Area of effective electric field; REMOVAL; CADMIUM; KAOLIN; LEAD;
D O I
10.1007/s11368-020-02803-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Electrokinetic (EK) soil remediation is significantly affected by the electrode configurations. Therefore, this study was conducted to compare the performance of one-dimensional (1D) and two-dimensional (2D) arrays with respect to the remediation of heavy metal-contaminated soils. Materials and methods A series of laboratory-scale experiments were carried out using two types of soils: kaolinite soil (KS) artificially spiked with heavy metals (Cd, Cu, Pb, Ni, and Zn) and smelter soil (SS) contaminated with Cu and Pb, obtained near a closed smelting factory. First, stepwise experiments on the KS were conducted to compare the EK performance between the 1D and 2D electrode arrays. More specifically, the effect of the number of anode-cathode pairs was investigated in the experiments on the 1D electrode configuration, and trigonal and hexagonal arrangements were compared in the 2D EK experiments. Additionally, the performance of the trigonal array was evaluated according to changes in the anode positions, to switch the areas of effective and ineffective electric field. Results and discussion The removal efficiencies of the 1D electrode configuration with four anode-cathode pairs (eight electrodes in total) were 69.1% for Cd, 69.2% for Cu, 74.7% for Ni, 28.3% for Pb, and 71.3% for Zn. The removal efficiencies of the 2D hexagonal electrode array, with a similar number of electrodes (six anodes and one cathode for seven electrodes in total), were 79.8% (Cd), 82.6% (Cu), 83.7% (Ni), 34.3% (Pb), and 81.1% (Zn). The total electric power consumptions for the two types of electrode configurations were investigated to be 15.6 and 22.0 kWh/ton, respectively. Despite the increase in electric power consumption in the 2D electrode configuration, it was more efficient than the 1D configuration due to the increased area of effective (active) electric field and subsequently higher removal efficiency. As a result of changing the positions of anodes in the trigonal 2D arrangement, the removal efficiencies of Cu and Pb were increased to a level similar to that obtained with the hexagonal configuration. Conclusions This study demonstrated that a 2D electrode configuration increased the EK removal efficiency of contaminants compared with a 1D array. However, cost-effectiveness should be taken into account when optimizing electrode design. Furthermore, the performance of the trigonal 2D EK process was improved by changing the positions of anodes, as a result of the increase in the removal efficiency and decrease in the electrode cost and energy consumption.
引用
收藏
页码:2755 / 2769
页数:15
相关论文
共 50 条
  • [21] Heavy metal tolerance and potential for remediation of heavy metal-contaminated saline soils for the euhalophyte Suaeda salsa
    Shang, Cailing
    Wang, Lei
    Tian, Changyan
    Song, Jie
    PLANT SIGNALING & BEHAVIOR, 2020, 15 (11)
  • [22] Biosurfactant-assisted bio-electrokinetic enhanced remediation of heavy metal-contaminated soil
    Narenkumar, Jayaraman
    Das, Bhaskar
    Abilaji, Subramani
    Sathishkumar, Kuppusamy
    Alsalhi, Mohamad S.
    Devanesan, Sandhanasamy
    Rajasekar, Aruliah
    Malik, Tabarak
    FRONTIERS IN MICROBIOLOGY, 2024, 15
  • [23] Simulation of drying stresses in wood Part I: comparison between one- and two-dimensional modelsPart I: comparison between one- and two-dimensional models
    S. Svensson
    A. Mårtensson
    Holz als Roh- und Werkstoff, 1999, 57 : 129 - 136
  • [24] Geospatial evaluation and bio-remediation of heavy metal-contaminated soils in arid zones
    Mohamed, Elsayed Said
    Jalhoum, Mohamed E. M.
    Hendawy, Ehab
    El-Adly, Ahmed M.
    Nawar, Said
    Rebouh, Nazih Y.
    Saleh, Ahmed
    Shokr, Mohamed. S.
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2024, 12
  • [25] Comparison of Remediation Mechanism of Heavy Metal-Contaminated Soil by Combined Leaching and Two-Step Leaching
    Zhang, Shuqin
    Zhang, Xu
    Zhang, Kening
    Yuan, Boyue
    Ren, Dajun
    Zhang, Xiaoqing
    WATER AIR AND SOIL POLLUTION, 2023, 234 (06):
  • [26] Particle morphology and mineral structure of heavy metal-contaminated kaolin soil before and after electrokinetic remediation
    Roach, Nicole
    Reddy, Krishna R.
    Al-Hamdan, Ashraf Z.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 165 (1-3) : 548 - 557
  • [27] Relations between sorption behavior and electrokinetic remediation effect in soils contaminated with heavy metals
    Shen, Zhemin
    Ju, Bingxin
    Chen, Xuejun
    Wang, Wen-Hua
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2008, 46 (05): : 485 - 491
  • [28] Advances in Soil Amendments for Remediation of Heavy Metal-Contaminated Soils: Mechanisms, Impact, and Future Prospects
    Nie, Xinyi
    Huang, Xianhuai
    Li, Man
    Lu, Zhaochi
    Ling, Xinhe
    TOXICS, 2024, 12 (12)
  • [29] Biochar Is Not Durable for Remediation of Heavy Metal-Contaminated Soils Affected by Acid-Mine Drainage
    Qin, Junhao
    Wang, Xi
    Ying, Jidong
    Lin, Chuxia
    TOXICS, 2022, 10 (08)
  • [30] Remediation of Heavy Metal-Contaminated Soils Using Phosphorus: Evaluation of Bioavailability Using an Earthworm Bioassay
    K. A. Maenpaa
    J. V. K. Kukkonen
    M. J. Lydy
    Archives of Environmental Contamination and Toxicology, 2002, 43 : 0389 - 0398