Electrokinetic remediation of heavy metal-contaminated soils: performance comparison between one- and two-dimensional electrode configurations

被引:35
|
作者
Kim, Soon-Oh [1 ,2 ]
Jeong, Jin Young [3 ]
Lee, Woo-Chun [1 ,2 ]
Yun, Seong-Taek [4 ,5 ]
Jo, Ho Young [4 ,5 ]
机构
[1] Gyeongsang Natl Univ GNU, Dept Geol, Jinju 52828, South Korea
[2] Gyeongsang Natl Univ GNU, Res Inst Nat Sci RINS, Jinju 52828, South Korea
[3] Korea Environm Corp, Dept Soil & Groundwater, Incheon 22689, South Korea
[4] Korea Univ, Dept Earth & Environm Sci, Seoul 02841, South Korea
[5] Korea Univ, SMART SEM Res Ctr, Seoul 02841, South Korea
关键词
Electrokinetic remediation; Electrode configuration; Heavy metals; Area of effective electric field; REMOVAL; CADMIUM; KAOLIN; LEAD;
D O I
10.1007/s11368-020-02803-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Electrokinetic (EK) soil remediation is significantly affected by the electrode configurations. Therefore, this study was conducted to compare the performance of one-dimensional (1D) and two-dimensional (2D) arrays with respect to the remediation of heavy metal-contaminated soils. Materials and methods A series of laboratory-scale experiments were carried out using two types of soils: kaolinite soil (KS) artificially spiked with heavy metals (Cd, Cu, Pb, Ni, and Zn) and smelter soil (SS) contaminated with Cu and Pb, obtained near a closed smelting factory. First, stepwise experiments on the KS were conducted to compare the EK performance between the 1D and 2D electrode arrays. More specifically, the effect of the number of anode-cathode pairs was investigated in the experiments on the 1D electrode configuration, and trigonal and hexagonal arrangements were compared in the 2D EK experiments. Additionally, the performance of the trigonal array was evaluated according to changes in the anode positions, to switch the areas of effective and ineffective electric field. Results and discussion The removal efficiencies of the 1D electrode configuration with four anode-cathode pairs (eight electrodes in total) were 69.1% for Cd, 69.2% for Cu, 74.7% for Ni, 28.3% for Pb, and 71.3% for Zn. The removal efficiencies of the 2D hexagonal electrode array, with a similar number of electrodes (six anodes and one cathode for seven electrodes in total), were 79.8% (Cd), 82.6% (Cu), 83.7% (Ni), 34.3% (Pb), and 81.1% (Zn). The total electric power consumptions for the two types of electrode configurations were investigated to be 15.6 and 22.0 kWh/ton, respectively. Despite the increase in electric power consumption in the 2D electrode configuration, it was more efficient than the 1D configuration due to the increased area of effective (active) electric field and subsequently higher removal efficiency. As a result of changing the positions of anodes in the trigonal 2D arrangement, the removal efficiencies of Cu and Pb were increased to a level similar to that obtained with the hexagonal configuration. Conclusions This study demonstrated that a 2D electrode configuration increased the EK removal efficiency of contaminants compared with a 1D array. However, cost-effectiveness should be taken into account when optimizing electrode design. Furthermore, the performance of the trigonal 2D EK process was improved by changing the positions of anodes, as a result of the increase in the removal efficiency and decrease in the electrode cost and energy consumption.
引用
收藏
页码:2755 / 2769
页数:15
相关论文
共 50 条
  • [1] Electrokinetic remediation of heavy metal-contaminated soils: performance comparison between one- and two-dimensional electrode configurations
    Soon-Oh Kim
    Jin Young Jeong
    Woo-Chun Lee
    Seong-Taek Yun
    Ho Young Jo
    Journal of Soils and Sediments, 2021, 21 : 2755 - 2769
  • [2] Remediation of heavy metal-contaminated soils by electrokinetic technology: Mechanisms and applicability
    Wang, Yuchen
    Li, Ang
    Cui, Chongwei
    CHEMOSPHERE, 2021, 265
  • [3] Electrokinetic remediation of heavy metal-contaminated soils under reducing environments
    Reddy, KR
    Chinthamreddy, S
    WASTE MANAGEMENT, 1999, 19 (04) : 269 - 282
  • [4] A Review on Remediation Technology and the Remediation Evaluation of Heavy Metal-Contaminated Soils
    Xu, Lei
    Zhao, Feifei
    Xing, Xiangyu
    Peng, Jianbiao
    Wang, Jiaming
    Ji, Mingfei
    Li, B. Larry
    TOXICS, 2024, 12 (12)
  • [5] Electrokinetic remediation: Past experiences and future roadmap for sustainable remediation of metal-contaminated soils
    Taneja, Sonam
    Karaca, Oznur
    Haritash, Anil Kumar
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2024, 259
  • [6] Remediation of Heavy Metal-Contaminated Soils with Soil Washing: A Review
    Zheng, Xiao-Jun
    Li, Qi
    Peng, Hao
    Zhang, Jian-Xiong
    Chen, Wei-Jiang
    Zhou, Bu-Chan
    Chen, Ming
    SUSTAINABILITY, 2022, 14 (20)
  • [7] Remediation techniques for heavy metal-contaminated soils: Principles and applicability
    Liu, Lianwen
    Li, Wei
    Song, Weiping
    Guo, Mingxin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 633 : 206 - 219
  • [8] Development of novel assisting agents for the electrokinetic remediation of heavy metal-contaminated kaolin
    Yuan, Lizhu
    Xu, Xingjian
    Li, Haiyan
    Wang, Nana
    Guo, Na
    Yu, Hongwen
    ELECTROCHIMICA ACTA, 2016, 218 : 140 - 148
  • [9] EDDS-enhanced electrokinetic remediation of heavy metal-contaminated clay soils under neutral pH conditions
    Suzuki, Tasuma
    Niinae, Masakazu
    Koga, Toshiyuki
    Akita, Tadashi
    Ohta, Masaaki
    Choso, Tetsuo
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2014, 440 : 145 - 150
  • [10] Enhanced Techniques of Soil Washing for the Remediation of Heavy Metal-Contaminated Soils
    Yang, Xu
    Mao, Xinyu
    Shao, Xiaohou
    Han, Fengxiang
    Chang, Tingting
    Qin, Hengji
    Li, Minhui
    AGRICULTURAL RESEARCH, 2018, 7 (02) : 99 - 104