Evaluation of ventilation performance of monitor roof in residential area based on simplified estimation and CFD analysis

被引:21
|
作者
Kobayashi, Tomohiro [1 ]
Chikamoto, Tomoyuki [1 ]
Osada, Keishi [1 ]
机构
[1] Ritsumeikan Univ, Dept Architecture & Urban Design, Tokyo, Japan
基金
日本学术振兴会;
关键词
Monitor roof; Natural ventilation; CFD; LES; PFR; Wind tunnel; NATURAL VENTILATION; SOLAR CHIMNEY; AIR-FLOW; BUILDINGS; DYNAMICS; SYSTEM;
D O I
10.1016/j.buildenv.2013.01.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind-induced natural ventilation is beneficial to assure thermal comfort and to reduce cooling load in the hot and humid summertime. In the urban environment, where buildings are grouped closely, it is often difficult to obtain a large enough wind pressure difference to drive the natural ventilation. As architectural feature, this work focuses on "monitor roof" which has the potential to promote wind-induced natural ventilation, and aims to evaluate its ventilation performance. This paper analyses a two-story residential building model equipped with a monitor roof which is built in a long building row, assuming a densely populated residential area. Since the monitor roof shows complicated flow resistance, the conventional method to predict flow rate cannot be easily applied. Based on the correlation between internal pressure and flow rate, and wind pressure coefficients obtained from previous work, a simplified estimation method of flow rate is first applied in this paper. In addition, more detailed flow characteristics inside the room are analysed by Computational Fluid Dynamics using a Reynolds-Averaged Navier-Stokes model, and a certain level of accuracy is verified by comparison with wind tunnel measurement. By comparing flow rate between numerical simulation and measurement, the validity of the simplified estimation method is also verified. To analyse substantial ventilation performance including the effect of turbulence, numerical simulation using Large Eddy Simulation is also performed and particle tracking technique is applied. Based on those results, Purging Flow Rate is evaluated, and it is finally shown that the monitor roof can work well to promote natural ventilation. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:20 / 30
页数:11
相关论文
共 50 条
  • [21] CFD study of the natural ventilation performance of a parral type greenhouse with different numbers of spans and roof vent configurations
    Baeza, E. J.
    Perez-Parra, J. J.
    Lopez, J. C.
    Montero, J. I.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON GREENHOUSE COOLING, 2006, (719): : 333 - +
  • [22] Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
    Li, He
    Li, Yiming
    Yue, Xiang
    Liu, Xingan
    Tian, Subo
    Li, Tianlai
    PLOS ONE, 2020, 15 (09):
  • [23] Seasonal thermal performance evaluation of the composite planted roof in subtropical area
    Li, Yi
    Yang, Wansheng
    Ling, Zipeng
    Wang, Jing
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 591 - 602
  • [24] CFD based synergistic analysis of wind turbines for roof mounted integration
    Larin, P.
    Paraschivoiu, M.
    Aygun, C.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 156 : 1 - 13
  • [25] Evaluation of passive cooling through natural ventilation strategies in historic residential buildings using CFD simulations
    Iskandar, Layla
    Bay-Sahin, Ezgi
    Martinez-Molina, Antonio
    Beeson, Saadet Toker
    ENERGY AND BUILDINGS, 2024, 308
  • [26] An Analysis of the Ventilation Efficiency of Various Configurations of Inlet and Outlet Vents in a Residential Building by CFD Simulation
    Kim, Daeung Danny
    Kim, Hyejin
    Yim, Woong Seog
    Lim, Taesub
    BUILDINGS, 2024, 14 (11)
  • [27] Numerical analysis on thermal performance of roof contained PCM of a single residential building
    Li Dong
    Zheng Yumeng
    Liu Changyu
    Wu Guozhong
    ENERGY CONVERSION AND MANAGEMENT, 2015, 100 : 147 - 156
  • [28] Push-pull ventilation system: A CFD approach for the performance analysis
    DETEC, University of Naples, Federico II, Piazzale Tecchio 80, 80125 Naples, Italy
    不详
    International Journal of Ambient Energy, 2007, 28 (03): : 123 - 134
  • [29] Push-pull ventilation system: a CFD approach for the performance analysis
    Betta, V.
    Cascetta, F.
    Palombo, A.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2007, 28 (03) : 123 - 134
  • [30] CFD analysis of the performance of a local exhaust ventilation system in a hospital ward
    Chau, Oliver K. Y.
    Liu, Chun-Ho
    Leung, Michael K. H.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (03) : 257 - 271