Evaluation of ventilation performance of monitor roof in residential area based on simplified estimation and CFD analysis

被引:21
|
作者
Kobayashi, Tomohiro [1 ]
Chikamoto, Tomoyuki [1 ]
Osada, Keishi [1 ]
机构
[1] Ritsumeikan Univ, Dept Architecture & Urban Design, Tokyo, Japan
基金
日本学术振兴会;
关键词
Monitor roof; Natural ventilation; CFD; LES; PFR; Wind tunnel; NATURAL VENTILATION; SOLAR CHIMNEY; AIR-FLOW; BUILDINGS; DYNAMICS; SYSTEM;
D O I
10.1016/j.buildenv.2013.01.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind-induced natural ventilation is beneficial to assure thermal comfort and to reduce cooling load in the hot and humid summertime. In the urban environment, where buildings are grouped closely, it is often difficult to obtain a large enough wind pressure difference to drive the natural ventilation. As architectural feature, this work focuses on "monitor roof" which has the potential to promote wind-induced natural ventilation, and aims to evaluate its ventilation performance. This paper analyses a two-story residential building model equipped with a monitor roof which is built in a long building row, assuming a densely populated residential area. Since the monitor roof shows complicated flow resistance, the conventional method to predict flow rate cannot be easily applied. Based on the correlation between internal pressure and flow rate, and wind pressure coefficients obtained from previous work, a simplified estimation method of flow rate is first applied in this paper. In addition, more detailed flow characteristics inside the room are analysed by Computational Fluid Dynamics using a Reynolds-Averaged Navier-Stokes model, and a certain level of accuracy is verified by comparison with wind tunnel measurement. By comparing flow rate between numerical simulation and measurement, the validity of the simplified estimation method is also verified. To analyse substantial ventilation performance including the effect of turbulence, numerical simulation using Large Eddy Simulation is also performed and particle tracking technique is applied. Based on those results, Purging Flow Rate is evaluated, and it is finally shown that the monitor roof can work well to promote natural ventilation. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:20 / 30
页数:11
相关论文
共 50 条
  • [1] Experimental and CFD study of ventilation performance enhanced by roof window and mechanical ventilation system with different design strategies
    He, Yi
    Chu, Yingnan
    Zang, Haiyan
    Zhao, Jinyan
    Song, Yehao
    BUILDING AND ENVIRONMENT, 2022, 224
  • [2] Performance evaluation of hybrid ventilation system for residential buildings
    Yoshino, H.
    Yun, S. H.
    Lee, J. H.
    Wada, J.
    Research in Building Physics and Building Engineering, 2006, : 721 - 729
  • [3] Global and regional estimation and evaluation of suitable roof area for solar and green roof applications
    Urge-Vorsatz, Diana
    Chatterjee, Souran
    Cabeza, Luisa F.
    Molnar, Gergely
    DEVELOPMENTS IN THE BUILT ENVIRONMENT, 2025, 21
  • [4] Analysis of flow field for full open-roof glass greenhouse with nature ventilation in summer based on CFD
    Wang X.
    Zhang W.
    Zhang L.
    Guan Z.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2016, 47 (10): : 332 - 337
  • [5] An investigation on outdoor ventilation performance in high-rise residential districts based on CFD simulation and field measurement
    Peng, Yunlong
    Gao, Zhi
    Ding, Wowo
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3035 - 3041
  • [6] CFD modelling and thermal performance analysis of a wooden ventilated roof structure
    Giacomo Villi
    Wilmer Pasut
    Michele De Carli
    Building Simulation, 2009, 2 : 215 - 228
  • [7] CFD modelling and thermal performance analysis of a wooden ventilated roof structure
    Villi, Giacomo
    Pasut, Wilmer
    De Carli, Michele
    BUILDING SIMULATION, 2009, 2 (03) : 215 - 228
  • [8] Evaluation of Energy and Ventilation Performance of Individual Room Control Ventilation System in Residential Building
    Shim, Chanhyung
    Seong, Namchul
    Hong, Goopyo
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 661 - 666
  • [9] CFD modeling on natural and forced ventilation during hydrogen leaks in a pressure regulator process of a residential area
    Lee, Jaewon
    Cho, Sunghyun
    Cho, Hyungtae
    Cho, Seungsik
    Lee, Inkyu
    Moon, Il
    Kim, Junghwan
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 161 : 436 - 446
  • [10] Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System
    Usman, Fathoni
    Abu Bakar, Ahmad Ridzuan
    PROCEEDINGS OF AICCE'19: TRANSFORMING THE NATION FOR A SUSTAINABLE TOMORROW, 2020, 53 : 1613 - 1628