Extension Strategy for 110kV Bus-Bar Differential Protection in Smart Substation

被引:0
|
作者
Dai Shiqiang [1 ]
Qiu Yutao [2 ]
Wu Jing [1 ]
Hou Weihong [1 ]
机构
[1] Hangzhou Power Supply Co, Hangzhou 310000, Zhejiang, Peoples R China
[2] Zhejiang Elect Power Co, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Smart Substation; 110kV Bus-Bar Differential Protection; Extension Strategy; Maintenance Mechanism; Safety measures;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The intuitive secondary circuits of relay protection have been changed into abstract data streams in smart substation. Reasonable safety measures must be taken during the extension with the consideration of the influence of extended lines. Based on the analysis of maintenance mechanism for smart substation, the extension strategy for 110kV Bus-Bar Differential Protection and corresponding safety measures have been proposed and been proved practical by the 110 kV Xuelin Line I& II extension project in 220 kV Wenjin smart substation.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Model-parameter identification based bus-bar protection principle
    Suonan, Jia-Le
    Deng, Xu-Yang
    Song, Guo-Bing
    Jiao, Zai-Bin
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (22): : 92 - 99
  • [22] 110 KV SWITCHGEAR WITH PANTOGRAPH ISOLATORS AS BUS-BAR SECTIONALIZERS (FERLACH-MARIA RAIN POWER-PLANT)
    SPERL, E
    ELIN ZEITSCHRIFT, 1978, 30 (04): : 169 - 172
  • [23] A Novel Bus-bar Protection Principle Based on Model Parameter Identification
    Deng, Xuyang
    Song, Guobing
    Kang, Xiaoning
    Du, Bin
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3389 - 3400
  • [24] The differential current calculation of the 110kV double bus single segment connection mode
    Dong, Jun
    Chen, Xin
    Zhang, Feng
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [25] Bus-bar protection scheme based on correlation of coefficients of sampled current values
    Li, Xiaobo
    Luan, Qingwu
    Wang, Yu
    Tan, Ling
    Hao, Houtang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, (12): : 107 - 111
  • [26] Research situation of 110 kV smart substation technology
    Pang, Hong-Mei
    Li, Huai-Hai
    Zhang, Zhi-Xin
    Zhou, Hai-Yan
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (06): : 146 - 150
  • [27] Analysis of mal-operation of transformer's differential protection in a 110 kV substation
    Pan, Shu-Yan
    Huang, Biao
    Chen, Yong-Hua
    Li, Yong-Guo
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2005, 29 (19): : 87 - 89
  • [28] Model Study of Lightning Protection of 110 kV Substation
    Vasileva, Margreta
    Velikova, Neli
    Nikolaev, Nikolay
    2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2014, : 113 - 115
  • [29] Function and role of bus bar protection relay in distribution substation
    Matsuda, Yuki
    Inui, Takayuki
    ELECTRICAL ENGINEERING IN JAPAN, 2023, 216 (04)
  • [30] Improvement on the application of RCS-915AB numerical bus-bar protection
    Su, Hai-Tao
    Hou, Qun-Bao
    Dong, Xiao-Ping
    Zhang, Zhi-Hong
    Li, Hang
    Li, Jun-Hua
    Jia, Wei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (21): : 112 - 114