A simple method for approximate estimation of the displacement response of base-isolated structures

被引:5
|
作者
Yaghmaei-Sabegh, Saman [1 ]
Jafari, Ebrahim [1 ]
Neekmanesh, Shabnam [1 ]
机构
[1] Univ Tabriz, Dept Civil Engn, Tabriz, Iran
关键词
Maximum nonlinear roof displacement; Seismic base-isolated structures; Near-field ground motion record; Nonlinear time history analysis; Equivalent SDOF system; REINFORCED-CONCRETE BUILDINGS; NONLINEAR RESPONSE; ISOLATION SYSTEMS; PERFORMANCE; DRIFT; EARTHQUAKES; MODEL;
D O I
10.1016/j.istruc.2022.05.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study is a new attempt to provide a simple method for approximate estimation of the displacement response of base-isolated structures. For this purpose, first the accuracy of the existing methods which have been presented for base-isolated buildings is examined by comparison their estimations with the results of time history analyses of the 2, 4, 6, 8, 10 and 12 stories base-isolated models under 40 near-field and 40 far-field ground motion records. Then, a new method is proposed which is based on equivalent linear SDOF system with considering modified values of optimum damping ratio and effective period factor for base-isolated structures. The optimum damping ratio for base-isolated structures is obtained 31% and 23% for far- and near-field ground motion records, respectively. An effective period factor of 2.02 and 1.99 is extracted as a suitable value for obtaining the period of equivalent linear structure subjected to far- and near-field ground motion records, respectively. Results show that the proposed method not only has practically more simple procedure than the others, but also can provide reasonable estimates of the maximum nonlinear roof displacement of base-isolated structures subjected to an individual ground motion record. It's worth mentioning that most of the equivalent linearization methods presented in the past use displacement ductility ratio as a key parameter for estimating the nonlinear displacement of base-isolated structures while the proposed method doesn't need to such a parameter which cannot be easily predicted without performing nonlinear time history analysis. Therefore, as another attempt in this study, suitable approximate values of ductility ratio and other important coefficients are recommended for a number of existing approximate methods to improve their estimations for base-isolated structures.
引用
收藏
页码:1570 / 1583
页数:14
相关论文
共 50 条
  • [31] WIND EFFECTS ON BASE-ISOLATED STRUCTURES
    CHEN, Y
    AHMADI, G
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1992, 118 (08): : 1708 - 1727
  • [32] Predictive control of base-isolated structures
    Inaudi, J.
    Lopez-Almansa, F.
    Kelly, J.M.
    Rodellar, J.
    Earthquake Engineering and Structural Dynamics, 1992, 21 (06) : 471 - 482
  • [33] Real-complex hybrid modal response spectrum method for seismically base-isolated structures
    Li, Shiyuan
    Tan, Ping
    Song, Xiao
    Yang, Kui
    STRUCTURES, 2023, 55 : 2068 - 2085
  • [34] Characterization of Ductility and Inelastic Displacement Demand in Base-Isolated Structures Considering Cyclic Degradation
    Yaghmaei-Sabegh, Saman
    Safari, Sina
    Abdolmohammad-Ghayouri, Karim
    JOURNAL OF EARTHQUAKE ENGINEERING, 2019, 23 (04) : 557 - 591
  • [35] DAMPING EFFECTS ON THE SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES WITH LRB DEVICES
    Avossa, Alberto Maria
    Pianese, Giovanna
    INGEGNERIA SISMICA, 2017, 34 (02): : 3 - 30
  • [36] Displacement prediction equations for seismic design of single friction pendulum base-isolated structures
    da Silva, Andreia Horta Alvares
    Pohl, Diego Pizarro
    Stojadinovic, Bozidar
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (12): : 3880 - 3903
  • [37] Seismic response amplification of submerged secondary systems in base-isolated structures
    Shin, TM
    Kim, KJ
    ADVANCES IN COMPUTATIONAL TECHNIQUES FOR STRUCTURAL ENGINEERING, 1996, : 269 - 281
  • [38] SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES WITH VERTICAL-ROCKING COUPLING
    PAN, TC
    KELLY, JM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1984, 12 (05): : 681 - 702
  • [39] On the displacement control performance of base-isolated structures incorporating nonlinear negative stiffness device
    Zhang, Yafei
    Hu, Yuchen
    Zhou, Zihao
    Li, Ning
    Zhang, Dan
    Ma, Yuhong
    STRUCTURES, 2024, 64
  • [40] Seismic response control of base-isolated structures with fluid inerter damper
    Akhare, Ashish R.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2023, 13 (01) : 1 - 21