X-ray fluoroscopy noise modeling for filter design

被引:36
|
作者
Cesarelli, M. [1 ]
Bifulco, P. [1 ]
Cerciello, T. [1 ]
Romano, M. [1 ]
Paura, L. [1 ]
机构
[1] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, I-80125 Naples, Italy
关键词
Noise modeling; X-ray fluoroscopy; Poisson quantum noise; White compression; Skellam distribution; INTERVERTEBRAL KINEMATICS; IMAGES;
D O I
10.1007/s11548-012-0772-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery. Patient's screen for prolonged time requires substantial reduction in X-ray exposure: The limited number of photons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the models and a possible application to improve the performance of noise filtering. Quantum noise is modeled as a Poisson distribution and results strongly signal-dependent. However, fluoroscopic devices generally apply gray-level transformations (i.e., logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of the statistics of noise for fluoroscopic image differences was offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differences between the local pixel and the neighboring pixels have been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squared values > 0.8). Clipping effects of real sensors were also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Fluoroscopic noise modeling is useful to design effective procedures for noise estimation and image filtering. In particular, filter performance analysis has showed that the knowledge of the noise model and the accurate estimate of noise characteristics can significantly improve the image restoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).
引用
收藏
页码:269 / 278
页数:10
相关论文
共 50 条
  • [21] Effects of motion blurring in x-ray fluoroscopy
    Xue, P
    Wilson, DL
    [J]. MEDICAL PHYSICS, 1998, 25 (05) : 587 - 599
  • [22] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [23] Stent Enhancement Using a Locally Adaptive Unsharp Masking Filter in Digital X-ray Fluoroscopy
    Jiang, Yuhao
    Ekanayakea, Eranda
    [J]. MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [24] Hard X-ray wiggler front end filter design
    Schulte-Schrepping, Horst
    Hahn, Ulrich
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1042 - +
  • [25] Noise optimization of an active pixel sensor for real-time digital X-ray fluoroscopy
    Izadi, A. H.
    Karim, K. S.
    [J]. NOISE AND FLUCTUATIONS IN CIRCUITS, DEVICES, AND MATERIALS, 2007, 6600
  • [26] Feasibility of a large area x-ray sensitive vidicon for medical fluoroscopy: Signal and noise factors
    Luhta, R
    Rowlands, JA
    [J]. MEDICAL PHYSICS, 1997, 24 (05) : 609 - 620
  • [27] Noise optimisation analysis of an active pixel sensor for low-noise real-time X-ray fluoroscopy
    Izadi, M. H.
    Karim, K. S.
    [J]. IET CIRCUITS DEVICES & SYSTEMS, 2007, 1 (03) : 251 - 256
  • [28] Biplanar x-ray fluoroscopy for sacroiliac joint fusion
    Vanaclocha-Vanaclocha, Vicente
    Verdu-Lopez, Francisco
    Saiz-Sapena, Nieves
    Manuel Herrera, Juan
    Rivera-Paz, Marlon
    [J]. Neurosurgical Focus, 2016, 41
  • [29] HOW SAFE IS X-RAY AND FLUOROSCOPY FOR THE PATIENT AND THE DOCTOR
    CLEIN, NW
    [J]. JOURNAL OF PEDIATRICS, 1954, 45 (03): : 310 - 315
  • [30] THE INCORPORATION OF PICTURE STORAGE WITH THE TECHNIQUE OF X-RAY FLUOROSCOPY
    GOMBASH, W
    [J]. PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1957, 45 (03): : 383 - 383