Simultaneous determination of new-generation antidepressants in plasma by gas chromatography-mass spectrometry

被引:26
|
作者
Pietracci, Elisa [1 ]
Bermejo, Ana-Maria [2 ]
Alvarez, Ivan [2 ]
Cabarcos, Pamela [2 ]
Balduini, Walter [1 ]
Tabernero, Maria-Jesus [2 ]
机构
[1] Univ Urbino, Dept Toxicol, Fac Pharm, I-61029 Urbino, Italy
[2] Univ Santiago de Compostela, Toxicol Forens Serv, Inst Forens Sci, Fac Med, Santiago De Compostela 15782, Spain
关键词
Antidepressant SSRIs; Olanzapine; GC-MS; LLE; Plasma; SEROTONIN REUPTAKE INHIBITORS; ACTIVE METABOLITES; POSTMORTEM BLOOD; VALIDATION; EXTRACTION; ELECTRON; DRUGS;
D O I
10.1007/s11419-012-0152-7
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
We have developed a gas chromatography-mass spectrometry (GC-MS) method for plasma for the determination of new-generation antidepressants, including olanzapine (antipsychotic used in bipolar disorder), and antidepressant selective serotonin reuptake inhibitors (SSRIs), such as fluoxetine and its metabolite norfluoxetine, paroxetine, sertraline, venlafaxine, and mirtazapine. Sample preparation was performed by liquid-liquid extraction with tert-butyl methyl ether. Fluoxetine, norfluoxetine, sertraline, and paroxetine required subsequent derivatization with 1-(heptafluorobutyryl) imidazole (HFBI). The GC separation lasts a total of 23.76 min. Qualitative and quantitative analysis were performed using an electron-impact ionization gas chromatograph interfaced to a mass-selective detector in selected-ion monitoring mode to increase the sensitivity of the method. Method validation was performed taking into account linearity, sensitivity, selectivity, accuracy, precision, and recovery, achieving good results for all the parameters studied. Calibration curves were prepared in the range of 0.005-2 mu g/ml (according to the therapeutic and toxic concentrations of each individual compound), with all correlation coefficients R (2) > 0.99. The limit of quantification was between 0.005 and 0.1 mu g/ml, depending on the compound, whereas the limit of detection ranged from 0.0025 to 0.05 mu g/ml. The method is fast and simple, allowing the identification and quantification of some of the most widely used antidepressants at therapeutic or toxic concentrations, and may be useful in routine clinical and forensic toxicology analysis.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 50 条
  • [41] Simultaneous Determination of Propylene Glycol, Glycerol and Lactic Acid in Rat Plasma and Serum by Gas Chromatography-mass Spectrometry
    Liang, Demin
    Gao, Yihan
    Zheng, Saijing
    Li, Gang
    Wu, Da
    Shen, Yi
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (02) : 219 - 224
  • [42] DETERMINATION OF QUINUPRAMIN IN PLASMA AND URINE BY CAPILLARY COLUMN GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    BOUQUET, S
    GIRAULT, J
    LY, UH
    SAUX, MC
    LEFEBVRE, MA
    FOURTILLAN, JB
    JOURNAL OF CHROMATOGRAPHY, 1986, 383 (02): : 393 - 399
  • [43] PESTICIDES RESIDUE DETERMINATION IN CATTLE PLASMA BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY.
    Maffei, Daniele Fernanda
    de Araujo Nogueira, Ana Rita
    Govoni Brondi, Silvia Helena
    QUIMICA NOVA, 2009, 32 (07): : 1713 - 1716
  • [44] Rapid and sensitive determination of nalmefene in human plasma by gas chromatography-mass spectrometry
    Xie, S
    Suckow, RF
    Mason, BJ
    Allen, D
    Cooper, TB
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 143 - 149
  • [45] Buprenorphine and Norbuprenorphine Determination in Mice Plasma and Brain by Gas Chromatography-Mass Spectrometry
    Chiadmi, Fouad
    Schlatter, Joel
    ANALYTICAL CHEMISTRY INSIGHTS, 2014, 9 : 9 - 16
  • [46] Simultaneous Determination of Ibrutinib, Dihydroxydiol Ibrutinib, and Zanubrutinib in Human Plasma by Liquid Chromatography-Mass Spectrometry/Mass Spectrometry
    Guo, Yu-Jiao
    Du, Tian-Tian
    Yang, Yan-Ling
    Zhao, Yang
    Chen, Xiang-Long
    Ma, Hong
    Sun, Lu-Ning
    Wang, Yong-Qing
    THERAPEUTIC DRUG MONITORING, 2024, 46 (05) : 634 - 641
  • [47] Simultaneous Determination of Androgens and Progestogen in Surface Water and Sediment by Gas Chromatography-Mass Spectrometry
    Jin Wei
    Huang Bin
    Wang Bin
    Wang Dao-Wei
    Zhao Shi-Min
    Pan Xue-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (02) : 205 - 209
  • [48] Simultaneous determination of 118 pesticide residues in Chinese teas by gas chromatography-mass spectrometry
    Xin Yang
    De Chang Xu
    Jian Wei Qiu
    Hua Zhang
    Ying Chun Zhang
    Ai Jun Dong
    Ying Ma
    Jing Wang
    Chemical Papers, 2009, 63 : 39 - 46
  • [49] Simultaneous determination of ethylene glycol and glycolic acid in serum by gas chromatography-mass spectrometry
    Porter, WH
    Rutter, PW
    Yao, HH
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (07) : 591 - 597
  • [50] Simultaneous determination of 19 phthalate esters in cosmetics using gas chromatography-mass spectrometry
    Liang Jing
    Zhuang Wan'e
    Wei Danqi
    Ou Yan
    Gong Zhenbin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (03) : 273 - 279