Validation of a novel respiratory rate monitor based on exhaled humidity

被引:17
|
作者
Niesters, M. [1 ]
Mahajan, R. [2 ]
Olofsen, E. [1 ]
Boom, M. [1 ]
Garcia del Valle, S. [3 ]
Aarts, L. [1 ]
Dahan, A. [1 ]
机构
[1] Leiden Univ Med Ctr, Dept Anesthesiol, NL-2300 RC Leiden, Netherlands
[2] Univ Nottingham, Queens Med Ctr, Div Anaesthesia & Intens Care, Nottingham NG7 2UH, England
[3] Hosp Univ Fdn Alcorcon, Area Anestesia & Cuidados Crit, Madrid, Spain
关键词
complications; monitoring; postoperative care; recovery room; respiratory depression; respiratory rate; OXYGEN; PREVENTION; AGREEMENT; ACCURACY; CARE;
D O I
10.1093/bja/aes275
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Postoperative monitoring of ventilation is largely restricted to the measurement of haemoglobin-oxygen saturation (Sp(o2)) and respiratory rate (RR) derived from the ECG. Sp(o2) measurement is inadequate when used with supplemental oxygen and ECG-derived RR is subject to artifacts. A new monitor measures RR by quantifying the humidity of exhaled air (respiR8). The accuracy of the system was tested using a breathing simulator. In healthy volunteers, the respiR8 monitor was compared with two other methods of measuring RR: capnometry and counting of thoracic breathing movements. The ability of the monitor to track changes in RR resulting from the infusion of 2.5 g kg(1) fentanyl was assessed and compared with RR measured from a validated flow measurement system. The RR in 50 postoperative patients measured with the respiR8 was compared with that derived from the ECG. RR values were compared by population-based BlandAltman analyses. The respiR8 monitor was accurate in the range required in clinical practice. There was a close agreement between RR from respiR8, capnometry, and manual counting of respiratory movements without bias (limits of agreement 1 bpm). The respiR8 monitor was well able to accurately track RR changes from fentanyl. In postoperative patients, RR from respiR8 and ECG had a bias of 1.7 (5.7) bpm due to greater RR values observed from the ECG due to artifacts. The respiR8 gives an accurate measurement of RR and is useful in postoperative care.
引用
收藏
页码:981 / 989
页数:9
相关论文
共 50 条
  • [31] Design, Development and Clinical Validation of a Wrist-based Optical Heart Rate Monitor
    Preejith, S. P.
    Alex, Annamol
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 493 - 498
  • [32] VALIDATION OF HEART RATE MONITOR-BASED PREDICTIONS OF OXYGEN UPTAKE AND ENERGY EXPENDITURE
    Montgomery, Paul G.
    Green, Daniel J.
    Etxebarria, Naroa
    Pyne, David B.
    Saunders, Philo U.
    Minahan, Clare L.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (05) : 1489 - 1495
  • [33] Validation Of An Integrated Heart Rate/Physical Activity Monitor
    Gaesser, Glenn A.
    Clark, Brian R.
    Parker, B. Eugene, Jr.
    Olowin, Aaron B.
    Richardson, Neal T.
    Blessinger, Jason R.
    Sawyer, Brandon J.
    Davis, Christopher K.
    Welk, Gregory J.
    Irving, Brian A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S556 - S556
  • [34] Remote monitor system of temperature and humidity based on internet
    College of Applied Nuclear and Automation Engineering, Chengdu University of Technology, Chengdu 610059, China
    Hedianzixue Yu Tance Jishue, 2006, 2 (234-236+233):
  • [35] Development and validation of a diagnostic model for acute respiratory distress syndrome based on volatile organic compounds in exhaled breath
    Zhang, Shiqi
    Hagens, Laura A.
    Heijnen, Nanon F. L.
    Schultz, Marcus J.
    Van der Poll, Tom
    Smit, Marry R.
    Schnabel, Ronny M.
    Bergmans, Dennis C. J. J.
    Bos, Lieuwe D. J.
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [36] Respiratory rate monitoring based on all-fiber strain-induced humidity sensor
    Lin, Jiahui
    Chen, Hao
    Ling, Qiang
    Shen, Qiuyi
    Luo, Si
    Akhtar, Ali
    Zhu, Chen
    Yu, Zhangwei
    Liu, Lifu
    Guan, Zuguang
    Chen, Daru
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [37] Development and characterization of a point-of care rate-based transcutaneous respiratory status monitor
    Ge, Xudong
    Adangwa, Prosper
    Lim, Ja Young
    Kostov, Yordan
    Tolosa, Leah
    Pierson, Richard
    Herr, Daniel
    Rao, Govind
    MEDICAL ENGINEERING & PHYSICS, 2018, 56 : 36 - 41
  • [38] Design and validation of a respiratory rate estimation algorithm based on photoplethysmography (PPG) signal
    Icazatti, Fernando
    Dell'Aquila, Carlos
    Leber, Eric Laciar
    2021 XIX WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2021,
  • [39] Does Chest Attachment of an Automated Respiratory Rate Monitor Influence the Actual Respiratory Rate in Children Under Five?
    Hellden, Daniel
    Baker, Kevin
    Habte, Tedila
    Batisso, Esey
    Orsini, Nicola
    Kallander, Karin
    Alfven, Tobias
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2020, 102 (01): : 20 - 27
  • [40] Multichannel esophageal signals to monitor respiratory rate in preterm infants
    Corine Bürgin
    Patrizia Simmen
    Nishant Gupta
    Lilian Suter
    Samuel Kreuzer
    Andreas Haeberlin
    Sven M. Schulzke
    Daniel Trachsel
    Thomas Niederhauser
    Kerstin Jost
    Pediatric Research, 2022, 91 : 572 - 580