Development of a Miniature Mass Spectrometry System for Point-of-Care Analysis of Lipid Isomers Based on Ozone-Induced Dissociation

被引:14
|
作者
Liu, Xinwei [1 ]
Jiao, Bin [1 ]
Cao, Wenbo [1 ]
Ma, Xiaoxiao [1 ]
Xia, Yu [2 ]
Blanksby, Stephen J. [3 ]
Zhang, Wenpeng [1 ]
Ouyang, Zheng [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[3] Queensland Univ Technol, Cent Analyt Res Facil & Sch Chem & Phys, Brisbane, Qld 4000, Australia
基金
中国国家自然科学基金;
关键词
NM ULTRAVIOLET PHOTODISSOCIATION; DOUBLE-BOND POSITION; STRUCTURAL-CHARACTERIZATION; ELECTROSPRAY-IONIZATION; ACID ISOMERS; FATTY-ACIDS; GLYCEROPHOSPHOLIPIDS; ELUCIDATION; OZONOLYSIS; METABOLISM;
D O I
10.1021/acs.analchem.2c03112
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Disorder of lipid homeostasis is closely associated with a variety of diseases. Although mass spectrometry (MS) approaches have been well developed for the characterization of lipids, it still lacks an integrated and compact MS system that is capable of rapid and detailed lipid structural characterization and can be conveniently transferred into different laboratories. In this work, we describe a novel miniature MS system with the capability of both ozone-induced dissociation (OzID) and collision-induced dissociation (CID) for the assignment of sites of unsaturation and sn-positions in glycerolipids. A miniature ozone generator was developed, which can be operated at a relatively high pressure. By maintaining high-concentration ozone inside the linear ion trap, OzID efficiency was significantly improved for the identification of C=C locations in unsaturated lipids, with reaction times as short as 10 ms. Finally, the miniature OzID MS system was applied to the analysis of C=C locations and sn-positions of lipids from biological samples. Direct sampling and fast detection of changes in phospholipid isomers were demonstrated for the rapid discrimination of breast cancer tissue samples, showing the potential of the miniature OzID MS system for point-of-care analysis of lipid isomer biomarkers in complex samples.
引用
收藏
页码:13944 / 13950
页数:7
相关论文
共 50 条
  • [21] Miniature mass spectrometer-based point-of-care assay for quantification of metformin and sitagliptin in human blood and urine
    Chen, Jingying
    Li, Yaohan
    Chen, Jingjing
    Wang, Ruimin
    Lu, Miaoshan
    Yu, Changbin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (14) : 3305 - 3312
  • [22] Development of Localized Surface Plasmon Resonance-Based Point-of-Care System
    Xiaodong Zhou
    Ten It Wong
    Hong Yan Song
    Lin Wu
    Yi Wang
    Ping Bai
    Dong-Hwan Kim
    Sum Huan Ng
    Man Siu Tse
    Wolfgang Knoll
    Plasmonics, 2014, 9 : 835 - 844
  • [23] Development of Localized Surface Plasmon Resonance-Based Point-of-Care System
    Zhou, Xiaodong
    Wong, Ten It
    Song, Hong Yan
    Wu, Lin
    Wang, Yi
    Bai, Ping
    Kim, Dong-Hwan
    Ng, Sum Huan
    Tse, Man Siu
    Knoll, Wolfgang
    PLASMONICS, 2014, 9 (04) : 835 - 844
  • [24] Rapid analysis of whole blood by paper spray mass spectrometry for point-of-care therapeutic drug monitoring
    Espy, Ryan D.
    Manicke, Nicholas E.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2012, 137 (10) : 2344 - 2349
  • [25] A Point-of-Care Test System for Biochemical Blood Analysis Based on ADUC824
    Hui Wang Qing Tian Liying Jiang Chunxiu Liu Zonghui Guo Xinxia Cai State Key Laboratory of Transducer TechnologyInstitute of ElectronicsChinese Academy of Science Chinese Academy of SciencesBeijing China Graduate School of Chinese Academy of SciencesBeijing China
    稀有金属材料与工程, 2006, (S3) : 75 - 79
  • [26] Improved Point-of-Care Mass Spectrometry Analysis with Thin-Layer Chromatography-Based Two-Dimensional Separation and Spray Ionization
    Ju, Zisheng
    Guo, Xiangyu
    Li, Linsen
    Tang, Yao
    Qiu, Mantang
    Zhang, Wenpeng
    Ouyang, Zheng
    Ma, Qiang
    Analytical Chemistry, 2025, 97 (01) : 712 - 720
  • [27] A point-of-care test system for biochemical blood analysis based on ADUC824
    Wang, Hui
    Tian, Qing
    Jiang, Liying
    Liu, Chunxiu
    Guo, Zonghui
    Cai, Xinxia
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 75 - 79
  • [28] Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
    Tsounidi, Dimitra
    Koukouvinos, Georgios
    Christianidis, Vasilios
    Legaki, Evangelia
    Giogli, Vasiliki
    Panagiotopoulou, Konstantina
    Taka, Styliani
    Ekaterinidi, Zoi
    Kakabakos, Sotirios
    Raptis, Ioannis
    Petrou, Panagiota
    BIOSENSORS-BASEL, 2021, 11 (08):
  • [29] A smartphone-based automated fluorescence analysis system for point-of-care testing of Hg(II)
    Chen, Yafei
    Zhang, Ke
    Liu, Yuan
    Zhang, Chunsun
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2022, 15 (05)
  • [30] Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing
    Yeh, Chia-Hsien
    Zhao, Zi-Qi
    Shen, Pi-Lan
    Lin, Yu-Cheng
    SENSORS, 2014, 14 (09) : 16148 - 16158