The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants

被引:33
|
作者
Uruc, Vedat [1 ]
Ozden, Raif [1 ]
Dogramaci, Yunus [1 ]
Kalaci, Aydiner [1 ]
Dikmen, Besir [1 ]
Yildiz, Omer Serkan [1 ]
Yengil, Erhan [2 ]
机构
[1] Mustafa Kemal Univ, Fac Med, Dept Orthoped & Traumatol, Antakya, Hatay, Turkey
[2] Mustafa Kemal Univ, Fac Med, Dept Family Med, Antakya, Hatay, Turkey
关键词
Intramedullary nailing; Fluoroscopy; Electromagnetic guidance; AIMING DEVICE; RADIATION-EXPOSURE; FEMORAL NAILS; TIBIAL NAILS; INTERLOCKING; SCREWS; FRACTURES; INSERTION; FIXATION; SURGEON;
D O I
10.1016/j.injury.2012.12.009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: In locking intramedullary nails, the most important problem is to put the distal interlocking screw accurately and quickly with minimum radiation exposure. The purpose of this clinical study was to compare the fluoroscopic time and surgical time required for distal locking with either free-hand fluoroscopic guidance or with an electromagnetic navigation system. Materials and methods: The study comprised 54 patients with 58 fractures of the lower extremity. The patients were divided in two groups: distal locking with freehand fluoroscopic guidance (group I) and distal locking with electromagnetic navigation (group II). The primary outcome in this study was fluoroscopy time. The secondary outcome was the operative time in distal interlocking. Results: In group I, the mean operation time was 108 (81-135) min, the mean time for distal interlocking was 18.35 (9-27) min, the total fluoroscopy time was 47.77 (19-74) s, the mean fluoroscopy time during distal interlocking was 18.29 (2-29) s and the mean attempt at number of distal locking for two screws was 9.96 (2-18) times. In group II, the mean operation time was 80.96 (63-100) min, the mean time for distal interlocking was 7.85 (6.5-10) min, the total fluoroscopy time was 22.59 (15-32) s, the mean fluoroscopy time during distal interlocking was 1.62 (0-2) s and the mean attempt number of distal interlocking was 2 (2-2). Conclusion: Fluoroscopy time to achieve equivalent precision is significantly reduced with electromagnetism-based surgical navigation compared with free hand fluoroscopic guidance. Also the operative time is significantly reduced with electromagnetic based navigation. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:863 / 866
页数:4
相关论文
共 50 条
  • [31] Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability
    Basci, Onur
    Karakasli, Ahmet
    Kumtepe, Erdem
    Guran, Orta
    Havitcioglu, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (01): : 21 - 26
  • [32] Insertion of distal locking screws of tibial intramedullary nails: A comparison between the free-hand technique and the SURESHOT™ Distal Targeting System
    Moreschini, O.
    Petrucci, V.
    Cannata, R.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (02): : 405 - 407
  • [33] Automatic pose recovery of the distal locking holes from single calibrated fluoroscopic image for computer-assisted intramedullary nailing of femoral shaft fractures
    Zheng, Guoyan
    Zhang, Xuan
    Nolte, Lutz-Peter
    MEDICAL IMAGING AND AUGMENTED REALITY, 2006, 4091 : 195 - 202
  • [34] Comparison of Elastic Intramedullary Nails and Locking Compression Plates on Oxidative Stress in Children with Distal Tibial Metaphyseal Fractures
    Xu, Yupeng
    Huang, Guoyuan
    Niu, Cunliang
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (11): : 1118 - 1120
  • [35] Distal femoral fixation: A biomechanical comparison of retrograde nail, retrograde intramedullary nail, and prototype locking retrograde nail
    Heiney, Jake P.
    Battula, Suneel
    O'Connor, Jill A.
    Ebraheim, Nabil
    Schoenfeld, Andrew J.
    Vrabec, Gregory
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 692 - 696
  • [36] Three-dimensional augmented reality surgical navigation with hybrid optical and electromagnetic tracking for distal intramedullary nail interlocking
    Ma, Longfei
    Zhao, Zhe
    Zhang, Boyu
    Jiang, Weipeng
    Fu, Ligong
    Zhang, Xinran
    Liao, Hongen
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (04):
  • [37] Computer-assisted auto-frame navigation system for distal locking of tibial intramedullary nails: a preliminary report on clinical application
    王军强
    赵春鹏
    王满宜
    苏勇刚
    胡磊
    孙磊
    张力丹
    刘文勇
    张辉
    高翌飞
    王田苗
    中华创伤杂志(英文版), 2006, (03) : 138 - 145
  • [38] Computer-assisted auto-frame navigation system for distal locking of tibial intramedullary nails: a preliminary report on clinical application
    王军强
    赵春鹏
    王满宜
    苏勇刚
    胡磊
    孙磊
    张力丹
    刘文勇
    张辉
    高翌飞
    王田苗
    ChineseJournalofTraumatology, 2006, (03) : 138 - 145
  • [39] Can we safely place the distal volar locking plate screws into the subchondral zone of a distal radius fracture using a 45 ° supination oblique view under fluoroscopic guidance?
    Kwon, Bong Cheol
    Lee, Yong Min
    Lee, Jung Woo
    Choi, Hyo Geun
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (03): : 947 - 953
  • [40] Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty
    Chen, Shih-Hao
    Chiang, Ming-Chieh
    Hung, Ching-Hua
    Lin, Shang-Chih
    Chang, Hsiao-Wei
    KNEE, 2014, 21 (01): : 224 - 231