Investigation of the Startup Condition of a Closed-Loop Oscillating Heat Pipe

被引:35
|
作者
Soponpongpipat, Nitipong [1 ]
Sakulchangsatjaati, Phrut [1 ]
Kammuang-Lue, Niti [1 ]
Terdtoon, Pradit [1 ]
机构
[1] Chiang Mai Univ, Dept Mech Engn, Chiang Mai 50200, Thailand
关键词
VISUALIZATION; PART;
D O I
10.1080/01457630802656876
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article develops a concept for a suitable startup condition for a closed-loop oscillating heat pipe (CLOHP). This concept was developed by using visual data and the thermodynamics theory for predicting the amount of vapor evaporation and condensation in a CLOHP. The visual data indicated that the key to a suitable startup is the amount of net vapor expansion in the evaporator and the amount of net collapsed vapor in the condenser. Initial dryout, an event that occurs after a startup failure, results when the net vapor expansion is higher than the amount of net vapor collapsed. This situation obstructs the replacement process. This is a mechanism in which the volume of mixture from the condenser section flows to the evaporator section to replace the volume of mixture that leaves the evaporator section. When the replacement process is impeded, all of the liquid in the evaporator section evaporates and the evaporator section is not refilled by the mixture from the condenser section. The evaporator section is then filled with vapor and initial dryout occurs. In addition, this article presents a mathematical model that predicts the operating temperature for a suitable startup condition. This prediction can be used to avoid a startup failure of a CLOHP. When comparing the model with that of the experimental data, a 16% error range was attained.
引用
收藏
页码:626 / 642
页数:17
相关论文
共 50 条
  • [41] Experiment investigation on visualization and operating characteristics of closed loop plate oscillating heat pipe with parallel channels
    Shi Wei-xiu
    Pan Li-sheng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2016, 23 (09) : 2410 - 2418
  • [42] Experiment investigation on visualization and operating characteristics of closed loop plate oscillating heat pipe with parallel channels
    Wei-xiu Shi
    Li-sheng Pan
    Journal of Central South University, 2016, 23 : 2410 - 2418
  • [43] Experiment investigation on visualization and operating characteristics of closed loop plate oscillating heat pipe with parallel channels
    史维秀
    潘利生
    Journal of Central South University, 2016, 23 (09) : 2410 - 2418
  • [44] INVESTIGATION OF LOOP HEAT PIPE STARTUP USING LIQUID CORE VISUALIZATION
    d'Entremont, B. P.
    Ochterbeck, J. M.
    HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2008, VOL 2, 2009, : 387 - 393
  • [45] An experimental investigation on the heat transfer characteristics of closed-loop pulsating heat pipe with graphene-water nanofluid
    Tharayil, Trijo
    Asirvatham, Lazarus Godson
    Manova, Stephen
    Vivek, V. M.
    Saravanan, M. S. Senthil
    Sajin, J. B.
    Wongwises, Somchai
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (22) : 12721 - 12737
  • [46] Thermal Performance of a Closed-Loop Pulsating Heat Pipe With Multiple Heat Sources
    Kammuang-Lue, Niti
    Sakulchangsatjatai, Phrut
    Terdtoon, Pradit
    HEAT TRANSFER ENGINEERING, 2014, 35 (13) : 1161 - 1172
  • [47] Flow patterns and heat-transfer characteristics of a top heat mode closed-loop oscillating heat pipe with check valves (THMCLOHP/CV)
    S. Thongdaeng
    S. Rittidech
    B. Bubphachot
    Journal of Engineering Thermophysics, 2012, 21 : 235 - 247
  • [48] Application of a closed-loop oscillating heat pipe with check valves (CLOHP/CV) on performance enhancement in air conditioning system
    Supirattanakul, P.
    Rittidech, S.
    Bubphachot, B.
    ENERGY AND BUILDINGS, 2011, 43 (07) : 1531 - 1535
  • [49] Flow patterns and heat-transfer characteristics of a top heat mode closed-loop oscillating heat pipe with check valves (THMCLOHP/CV)
    Thongdaeng, S.
    Rittidech, S.
    Bubphachot, B.
    JOURNAL OF ENGINEERING THERMOPHYSICS, 2012, 21 (04) : 235 - 247
  • [50] Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)
    Sangiamsuk, S.
    Bubphachot, B.
    Watanabe, O.
    Rittidech, S.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2014, 52 (08) : 531 - 540