Investigation of the Startup Condition of a Closed-Loop Oscillating Heat Pipe

被引:35
|
作者
Soponpongpipat, Nitipong [1 ]
Sakulchangsatjaati, Phrut [1 ]
Kammuang-Lue, Niti [1 ]
Terdtoon, Pradit [1 ]
机构
[1] Chiang Mai Univ, Dept Mech Engn, Chiang Mai 50200, Thailand
关键词
VISUALIZATION; PART;
D O I
10.1080/01457630802656876
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article develops a concept for a suitable startup condition for a closed-loop oscillating heat pipe (CLOHP). This concept was developed by using visual data and the thermodynamics theory for predicting the amount of vapor evaporation and condensation in a CLOHP. The visual data indicated that the key to a suitable startup is the amount of net vapor expansion in the evaporator and the amount of net collapsed vapor in the condenser. Initial dryout, an event that occurs after a startup failure, results when the net vapor expansion is higher than the amount of net vapor collapsed. This situation obstructs the replacement process. This is a mechanism in which the volume of mixture from the condenser section flows to the evaporator section to replace the volume of mixture that leaves the evaporator section. When the replacement process is impeded, all of the liquid in the evaporator section evaporates and the evaporator section is not refilled by the mixture from the condenser section. The evaporator section is then filled with vapor and initial dryout occurs. In addition, this article presents a mathematical model that predicts the operating temperature for a suitable startup condition. This prediction can be used to avoid a startup failure of a CLOHP. When comparing the model with that of the experimental data, a 16% error range was attained.
引用
收藏
页码:626 / 642
页数:17
相关论文
共 50 条
  • [1] Experimental investigations of a closed-loop oscillating heat pipe
    Dmitrin, V. I.
    Maidanik, Yu. F.
    HIGH TEMPERATURE, 2007, 45 (05) : 703 - 707
  • [2] Experimental investigations of a closed-loop oscillating heat pipe
    V. I. Dmitrin
    Yu. F. Maidanik
    High Temperature, 2007, 45 : 703 - 707
  • [3] Impact of particles on thermal performance of closed-loop oscillating heat pipe
    Riehl, R. R.
    Buschmann, M. H.
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [4] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [5] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [6] Motion and Heat-Transfer Analysis of a Closed-Loop Oscillating Heat Pipe with a Magnetic Field
    Wongkasem, K.
    Rittidech, S.
    Bubphachot, B.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2010, 17 (04) : 369 - 380
  • [7] Experimental study of flow state and heat transfer performance of closed-loop oscillating heat pipe
    Liu, Xiang-Dong
    Shi, Kai
    Guo, Yu-Han
    Lu, Jin-Li
    Wang, Shu-Juan
    Hao, Ying-Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (10): : 1735 - 1738
  • [8] Heat-transfer characteristics of a closed-loop oscillating heat-pipe with check valves
    Rittidech, S.
    Pipatpaiboon, N.
    Terdtoon, P.
    APPLIED ENERGY, 2007, 84 (05) : 565 - 577
  • [9] Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves
    Rittidech, S.
    Pipatpaiboon, N.
    Thongdaeng, S.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (02) : 545 - 550
  • [10] Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves
    S. Rittidech
    N. Pipatpaiboon
    S. Thongdaeng
    Journal of Mechanical Science and Technology, 2010, 24 : 545 - 550