Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging

被引:98
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Schneider, David [1 ]
Meyer, Mathias [1 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
CT angiography; Dual-source CT; Dual-energy CT; Monoenergetic Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST; QUALITY; SUBTRACTION; ARTERIES; REMOVAL; REPAIR;
D O I
10.1016/j.ejrad.2013.04.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. Methods: We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 +/- 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 +/- 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. Results: 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p > 0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p < 0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p < 0.05) compared to PEIs at equal noise levels (+18% on average; all p > 0.05) and equal or higher SNR (+49% on average; p < 0.01-0.35). Conclusions: Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E574 / E581
页数:8
相关论文
共 50 条
  • [31] Advantages of Dual-Source Dual-Energy CT for Radiation Therapy Planning
    Noid, G.
    Tai, A.
    Schott, D.
    Prah, D.
    Mistry, N.
    Robbins, J.
    Li, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E129 - E130
  • [32] Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours
    Chu, A. J.
    Lee, J. M.
    Lee, Y. J.
    Moon, S. K.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E891 - E898
  • [33] Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    Yu, Lifeng
    Primak, Andrew N.
    Liu, Xin
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (03) : 1019 - 1024
  • [34] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [35] Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Martin, Simon S.
    Nance, John W.
    Duguay, Taylor M.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Varga-Szemes, Akos
    van Assen, Marly
    Tesche, Christian
    Schoepf, U. Joseph
    RADIOLOGY, 2019, 293 (02) : 260 - 271
  • [36] Quantitative assessment of motion effects in dual-source dual-energy CT and dual-source photon-counting detector CT
    Ahmed, Zaki
    Rajendran, Kishore
    Gong, Hao
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [37] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [38] Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets
    De Cecco, Carlo N.
    Caruso, Damiano
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Ter Louw, Janet R.
    Perry, Jonathan D.
    Picard, Melissa M.
    Schaefer, Amanda R.
    Parker, Leland W.
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 695 - 699
  • [39] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Vitaliano Buffa
    Antonio Solazzo
    Valeria D’Auria
    Alessandra Del Prete
    Andrea Vallone
    Monica Luzietti
    Manuela Madau
    Roberto Grassi
    Vittorio Miele
    La radiologia medica, 2014, 119 : 934 - 941
  • [40] Improved Detection of Endoleaks in Virtual Monoenergetic Images in Dual-Energy CT Angiography Following EVAR
    Kazimierczak, Wojciech
    Kazimierczak, Natalia
    Lemanowicz, Adam
    Nowak, Ewa
    Migdalski, Arkadiusz
    Jawien, Arkadiusz
    Jankowski, Tomasz
    Serafin, Zbigniew
    ACADEMIC RADIOLOGY, 2023, 30 (12) : 2813 - 2824