Fast preparation of a desiccant array for the gradual desiccation method in protein crystallization screening

被引:2
|
作者
Lu, Qin-Qin [1 ]
Xie, Xu-Zhuo [1 ]
Liu, Yong-Ming [1 ]
Lu, Hui-Meng [1 ]
Chen, Da [1 ]
Wang, Xu-Sheng [1 ]
Yin, Da-Chuan [1 ]
机构
[1] Northwestern Polytech Univ, Sch Life Sci, Key Lab Space Biosci & Biotechnol, Xian 710072, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
VAPOR-DIFFUSION; MICROBATCH METHOD; EVAPORATION; EFFICIENCY; RESERVOIR;
D O I
10.1107/S0021889813009734
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The gradual desiccation method (GDM) is a modification of the vapor diffusion method for protein crystallization screening. This method can dramatically increase the chances of obtaining protein crystals and is therefore potentially useful for practical protein crystallization screening. However, it is troublesome to prepare the desiccant for the GDM because each of the 96 desiccants must be of the same mass. Repeated manual weighing of the desiccant (at least 96 times for one plate) to obtain the same amount is required, and manual distribution of the weighed desiccants to the respective reservoir wells is also necessary. These procedures require a considerable amount of labor and thus lower the efficiency of the screening process. Additionally, they reduce the applicability of this method in routine protein crystallization screening. To solve this problem, a high-throughput method is proposed, which involves dispensing an aqueous solution of salts (a combination of CoCl2 and AlCl3) into a droplet array (8 x 12, corresponding to the arrangement in a standard crystallization plate) on a piece of tape, then drying this array to obtain the final desiccant array. Simply covering and sealing this desiccant array over the crystallization droplets in the crystallization plate can give a perfect vapor diffusion screen. With this method, the labor and automation requirements of the GDM will be comparable to those of the conventional vapor diffusion method; furthermore, the amount of the desiccant can be easily and accurately controlled, allowing the GDM to be applied in daily protein crystallization screening.
引用
收藏
页码:817 / 822
页数:6
相关论文
共 32 条
  • [21] 3D-Printed High-Density Droplet Array Chip for Miniaturized Protein Crystallization Screening under Vapor Diffusion Mode
    Liang, Yi-Ran
    Zhu, Li-Na
    Gao, Jie
    Zhao, Hong-Xia
    Zhu, Ying
    Ye, Sheng
    Fang, Qun
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (13) : 11837 - 11845
  • [22] FAST AND SENSITIVE SCREENING METHOD FOR DETECTION OF TRICHOTHECENES IN MAIZE BY USING PROTEIN-SYNTHESIS INHIBITION IN CULTURED FIBROBLASTS
    SCOSSAROMANO, DA
    BICKEL, RE
    ZWEIFEL, U
    REINHARDT, CA
    LUTHY, JW
    SCHLATTER, CL
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1987, 70 (01): : 129 - 132
  • [23] Saturation-Transfer Difference (STD) NMR: A Simple and Fast Method for Ligand Screening and Characterization of Protein Binding
    Viegas, Aldino
    Manso, Joao
    Nobrega, Franklin L.
    Cabrita, Eurico J.
    JOURNAL OF CHEMICAL EDUCATION, 2011, 88 (07) : 990 - 994
  • [24] A MALDI-TOF MS based method for the fast screening of recombinant protein high-yield strains
    Liu, Xiaoyan
    Zhu, He
    Li, Yanan
    Qin, Hongqiang
    Ye, Mingliang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 482
  • [26] Fast gradient elution reversed-phase liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse - II. Data analysis
    Porter, Sarah E. G.
    Stoll, Dwight R.
    Paek, Changyub
    Rutan, Sarah C.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (02) : 163 - 172
  • [27] Preparation, activity and mechanism of a metallic Cu/TiO2 nanotube array catalyst by a fast solar drying method for photothermal CO2 reduction under concentrating light
    Zhang, Zekai
    Yan, Wei
    Wang, Ying
    Cui, Guokai
    Lu, Hanfeng
    CATALYSIS SCIENCE & TECHNOLOGY, 2024, 14 (15) : 4187 - 4197
  • [28] Fast gradient elution reversed-phase high-performance liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse - I. Chromatographic conditions
    Stoll, Dwight R.
    Paek, Changyub
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (02) : 153 - 162
  • [29] Linkup of a fast protein liquid chromatography system with a stirred thermostated cell for sterile preparation of liposomes by the proliposome- liposome method: Application to encapsulation of antibiotics, synthetic peptide immunomodulators, and a photosensitizer
    Veterinary Research Institute, Hudcova 70, 621 32 Brno, Czech Republic
    不详
    ANAL. BIOCHEM., 2 (131-139):
  • [30] Linkup of a fast protein liquid chromatography system with a stirred thermostated cell for sterile preparation of liposomes by the proliposome-liposome method: Application to encapsulation of antibiotics, synthetic peptide immunomodulators, and a photosensitizer
    Turanek, J
    Zaluska, D
    Neca, J
    ANALYTICAL BIOCHEMISTRY, 1997, 249 (02) : 131 - 139