Investigation of Hyfrecators and Their In Vitro Interference with Implantable Cardiac Devices

被引:13
|
作者
Weyer, Christopher [1 ]
Siegle, Ronald J. [2 ,3 ]
Girard, Guillaume [4 ]
机构
[1] Cleveland Clin Fdn, Dept Dermatol, Plast Surg Inst, Cleveland, OH 44195 USA
[2] Ctr Surg Dermatol, Westerville, OH USA
[3] Ohio State Univ, Div Dermatol, Columbus, OH 43210 USA
[4] Medtronic Inc, Cardiac Rhythm Management, Mounds View, MN USA
关键词
DERMATOLOGICAL SURGERY;
D O I
10.1111/j.1524-4725.2012.02526.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
BACKGROUND Guidelines exist for minimizing potential electromagnetic interference (EMI) with electrosurgical equipment in patients with cardiac rhythm management (CRM) devices. These guidelines encompass all electrosurgical devices but are not specific for hyfrecators. OBJECTIVE To investigate the potential interference of CRM devices by hyfrecators. MATERIALS AND METHODS Using a collagen-based saline gel, three implantable pulse generators (pacemakers) and three implantable cardioverter defibrillators were tested to measure the EMI from two commonly used hyfrecators. The six devices were tested using the hyfrecator under normal use settings and on maximum power. RESULTS Hyfrecators did not interfere with defibrillators and affected pacemakers only when used in close proximity to the device. For the pacemakers, atrial inhibition was observed at a distance of 3 cm on maximum hyfrecator settings and 1 cm at normal use settings. Ventricular inhibition occurred in very close proximity to the device (<1 cm) or in direct contact. CONCLUSION Hyfrecators are safe to use in patients with defibrillators and can be used in pacemaker patients within 2 inches of the device perimeter.
引用
收藏
页码:1843 / 1848
页数:6
相关论文
共 50 条
  • [1] Investigation of electrosurgery and interference with implantable cardiac devices
    Amin, Sima
    Homan, Katie
    Lee, Mary
    Housewright, Chad
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2019, 81 (04) : AB85 - AB85
  • [2] Hyfrecation and Interference With Implantable Cardiac Devices
    Amin, Sima D.
    Homan, Katie B.
    Assar, Manish
    Lee, Mary
    Housewright, Chad D.
    DERMATOLOGIC SURGERY, 2020, 46 (05) : 612 - 615
  • [3] Commentary on Hyfrecation and Interference With Implantable Cardiac Devices
    Soon, Seaver L.
    DERMATOLOGIC SURGERY, 2020, 46 (05) : 616 - 617
  • [4] An in vitro evaluation of electromagnetic interference between implantable cardiac devices and ophthalmic laser systems
    Sher, Neal A.
    Golben, Mikhail P.
    Kresge, Kathleen
    Selznick, Larry
    Adabag, Selcuk
    EUROPACE, 2011, 13 (04): : 583 - 588
  • [5] Electromagnetic Interference with Cardiac Implantable Devices by Household and Industrial Appliances
    Yonemura, Tomohide
    Koyama, Junjiroh
    Sakai, Yoshirou
    Morinaga, Keiko
    Kurosaki, Ryousuke
    Araki, Yasuyuki
    Kawano, Yosin
    Nozoe, Masayoshi
    Tayama, Shinji
    Honda, Toshihiro
    Nakao, Koichi
    JOURNAL OF ARRHYTHMIA, 2011, 27 (01) : 49 - 56
  • [6] Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
    Morava, Jan
    Richter, Ales
    Eichler, Jakub
    2019 PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MEASUREMENT (MEASUREMENT 2019), 2019, : 182 - 185
  • [7] Potential for Personal Digital Assistant interference with implantable cardiac devices
    Tri, JL
    Trusty, JM
    Hayes, DL
    MAYO CLINIC PROCEEDINGS, 2004, 79 (12) : 1527 - 1530
  • [8] Cellular phone interference testing of implantable cardiac defibrillators in vitro
    Bassen, HI
    Moore, HJ
    Ruggera, PS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (09): : 1709 - 1715
  • [9] Electromagnetic interference of implantable cardiac devices from a shoulder massage machine
    Yoshida, Saeko
    Fujiwara, Kousaku
    Kohira, Satoshi
    Hirose, Minoru
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (03) : 243 - 249
  • [10] Electromagnetic interference of implantable cardiac devices from a shoulder massage machine
    Saeko Yoshida
    Kousaku Fujiwara
    Satoshi Kohira
    Minoru Hirose
    Journal of Artificial Organs, 2014, 17 : 243 - 249