High-performance liquid chromatography and coulometric electrode array detector in serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 analyses

被引:22
|
作者
Nurmi, Tarja [1 ]
Tuomainen, Tomi-Pekka [1 ]
Virtanen, Jyrki [1 ]
Mursu, Jaakko [1 ]
Voutilainen, Sari [1 ]
机构
[1] Univ Eastern Finland, Inst Publ Hlth & Clin Nutr, FI-70211 Kuopio, Finland
基金
芬兰科学院;
关键词
25-Hydroxyvitamin D; Serum; HPLC; Coulometric electrode array detector; VITAMIN-D METABOLITES; ASSAY; HPLC; PLASMA;
D O I
10.1016/j.ab.2012.12.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The diode array detector in our high-performance liquid chromatography (HPLC) method for 25-hydroxyvitamin D-3 (25OHD(3)) and 25-hydroxyvitamin D-2 (25OHD(2)) did not perform satisfactorily for measuring human serum concentrations below 30 nM. Because of a need for a reliable self-managed method in ongoing and starting vitamin D studies of the laboratory, we decided to develop a chromatographic method applying coulometric electrode array detector (CEAD) and evaluate reliability of the method by participating in the Vitamin D External Quality Assessment Scheme (DEQAS). The limit of quantification for 25OHD(3) and 25OHD(2) of the new method was 0.36 pmol on column (3.6 nM), and linearity ranged from 5 to 2400 nM. Accuracy of the method was 90% for 25OHD(3) and 69% for 25OHD(2). The HPLC-CEAD results from five DEQAS rounds were in line with those of the other participating laboratories using HPLC methods. The HPLC-CEAD results for 25OHD(3) also corresponded to the results obtained with the Chromsystems HPLC method in a certified laboratory. The long-term coefficients of variation for 25OHD(3) were 6.2%, 7.8%, 5.2%, 6.7%, and 7.3% in concentrations of 27.5, 38.7, 48.4, 78.4, and 88.0 nM, respectively. The developed HPLC-CEAD method was shown to be applicable for determining 25OHD(3) and 25OHD(2) in human serum samples. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] RAPID QUANTITATION OF SERUM 25-HYDROXYVITAMIN D3 AND D2 BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Healy, M.
    Cox, G.
    Casey, M.
    Walsh, J. Bernard
    Laird, E.
    Crowley, V.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : S507 - S508
  • [22] Quantification of Serum 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 Using High-Performance Liquid Chromatography, Tandem Mass Spectrometry (LC-MS/MS): Correlation with PTH and Other Assay Methods.
    Salameh, W. A.
    Holmquist, B. X.
    Lee, G.
    Caston-Balderama, A.
    Huang, X.
    Clarke, N. J.
    Zhang, K.
    Reitz, E.
    Holick, M. F.
    ENDOCRINE REVIEWS, 2010, 31 (03)
  • [23] Relative effectiveness of oral 25-hydroxyvitamin D3 and vitamin D3 in raising wintertime serum 25-hydroxyvitamin D in older adults
    Cashman, Kevin D.
    Seamans, Kelly M.
    Lucey, Alice J.
    Stoecklin, Elisabeth
    Weber, Peter
    Kiely, Mairead
    Hill, Tom R.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2012, 95 (06): : 1350 - 1356
  • [24] A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays
    Lee, Sanghoo
    Kim, Joo-Hoon
    Kim, Seol-A
    Sun, Yeoun-Soo
    Lee, Anna
    Park, Seo-Jin
    Kim, Yun-Tae
    Lee, Kyoung-Ryul
    Kim, Young-Jin
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2016, 46 (06): : 645 - 653
  • [25] Hepatic Transport of 25-Hydroxyvitamin D3 Conjugates: A Mechanism of 25-Hydroxyvitamin D3 Delivery to the Intestinal Tract
    Gao, Chunying
    Liao, Michael Z.
    Han, Lyrialle W.
    Thummel, Kenneth E.
    Mao, Qingcheng
    DRUG METABOLISM AND DISPOSITION, 2018, 46 (05) : 581 - 591
  • [26] Selective monitoring of vitamin D2 and D3 supplementation with a highly specific 25-hydroxyvitamin D3 immunoassay with negligible cross-reactivity to 25-hydroxyvitamin D2
    Li, Bo
    Byrjalsen, Inger
    Glendenning, Paul
    Henriksen, Dennis B.
    Hoeck, Hans C.
    Taranto, Mario
    Vasikaran, Samuel
    Fraser, William D.
    Christiansen, Claus
    Qvist, Per
    CLINICA CHIMICA ACTA, 2009, 404 (02) : 144 - 148
  • [27] Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method
    Abouzid, Mohamed
    Karazniewicz-Lada, Marta
    Pawlak, Kornel
    Burchardt, Pawel
    Kruszyna, Lukasz
    Glowka, Franciszek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [28] The Association of 25-Hydroxyvitamin D3 and D2 with Behavioural Problems in Childhood
    Tolppanen, Anna-Maija
    Sayers, Adrian
    Fraser, William D.
    Lewis, Glyn
    Zammit, Stanley
    Lawlor, Debbie A.
    PLOS ONE, 2012, 7 (07):
  • [29] Gene-Regulatory Potential of 25-Hydroxyvitamin D3 and D2
    Hanel, Andrea
    Veldhuizen, Cor
    Carlberg, Carsten
    FRONTIERS IN NUTRITION, 2022, 9
  • [30] Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method
    Chen, Huiping
    McCoy, Leslie F.
    Schleicher, Rosemary L.
    Pfeiffer, Christine M.
    CLINICA CHIMICA ACTA, 2008, 391 (1-2) : 6 - 12