Objective: the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultmsonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs. Methods and material: 4176 (76.3%) of 5470 men aged 65-73 attended hospital-based US screening for an AAA at their local hospital. Two observers and one scanner were used. The maximal anterior-posterior (AP) of the dilated aorta, ol 2 cm above the bifurcation, and at the crossing of left renal vein was recorded. In 50 cases, blinded measurements were carried out by two observers. An AAA was defined as an AP diameter greater than 29 mm. Results: the standard deviation (S.D.) of the interobserver variability of ME distal AP diameter was 0.84. The mean distal AP diameter was 17.9 mm (S.D. 2.92). Combining these data, the estimated diagnostic sensitivity was 98.9%, the estimated diagnostic specificity tons 99.9%. The interobserver S.D. of the proximal AP diameter was 1.76. The mean proximal AP diameter was 18.4 mm (S.D. 2.45). Combining these data, the estimated diagnostic sensitivity was 87.4%, the estimated diagnostic specificity was 99.9%. Conclusion: US seems to be a valid screening method for AAA. Screening for proximal infrarenal aorta aneurysm remains acceptable because the majority of aortic diameters in this segment are so much smaller than the diameters that define an AAA.
引用
收藏
页码:472 / 475
页数:4
相关论文
共 50 条
  • [41] Population based ultrasonographic screening of abdominal aortic aneurysms
    Rajiah, Prabhakar
    Reiber, Johan H. C.
    Partovi, Sasan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (11): : 1605 - 1607
  • [42] Late results concerning feasibility and compliance from a randomized trial of ultrasonographic screening for abdominal aortic aneurysm
    Vardulaki, KA
    Walker, NM
    Couto, E
    Day, NE
    Thompson, SG
    Ashton, HA
    Scott, RAP
    BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 861 - 864
  • [43] Screening for aortic abdominal aneurysm in New Zealand
    Lawrenson, Ross
    NEW ZEALAND MEDICAL JOURNAL, 2012, 125 (1350) : 7 - 9
  • [44] Abdominal aortic aneurysm Is screening cost effective?
    McLaren, Eon H.
    BRITISH MEDICAL JOURNAL, 2009, 339
  • [45] Abdominal Aortic Aneurysm: What About Screening?
    Saucy, Francois
    Deglise, Sebastien
    Holzer, Thomas
    Briner, Lukas
    Benezit, Marie
    Delay, Charline
    Kazandjian, Caroline
    Corpataux, Jean-Marc
    CURRENT PHARMACEUTICAL DESIGN, 2015, 21 (28) : 4084 - 4087
  • [46] Screening for abdominal aortic aneurysm: A consensus statement
    Kent, KC
    Zwolak, RM
    Jaff, MR
    Hollenbeck, ST
    Thompson, RW
    Schermerhorn, ML
    Sicard, GA
    Riles, TS
    Cronenwett, JL
    JOURNAL OF VASCULAR SURGERY, 2004, 39 (01) : 267 - 269
  • [47] Screening for abdominal aortic aneurysm in asymptomatic adults
    Ali, Muhammad Usman
    Fitzpatrick-Lewis, Donna
    Miller, John
    Warren, Rachel
    Kenny, Meghan
    Sherifali, Diana
    Raina, Parminder
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (06) : 1855 - 1868
  • [48] Imaging Redundancy in Screening for Abdominal Aortic Aneurysm
    Gao, Guangzu
    Arora, Anita
    Scoutt, Leslie
    Mathur, Mahan
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (05) : 625 - 628
  • [49] ULTRASOUND SCREENING AND ABDOMINAL AORTIC-ANEURYSM
    COLLIN, J
    BRITISH MEDICAL JOURNAL, 1988, 297 (6644): : 360 - 360
  • [50] Screening of COPD patients for abdominal aortic aneurysm
    Flessenkaemper, Ingo H.
    Loddenkemper, Robert
    Roll, Stephanie
    Enke-Melzer, Kathrin
    Wurps, Henrik
    Bauer, Torsten T.
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2015, 10 : 1085 - 1091