Lead isotope analysis of archaeological metals by multiple-collector inductively coupled plasma mass spectrometry

被引:48
|
作者
Baker, J
Stos, S
Waight, T
机构
[1] Danish Lithosphere Ctr, DK-1350 Copenhagen, Denmark
[2] Victoria Univ Wellington, Sch Earth Sci, Wellington, New Zealand
[3] Univ Oxford, Archaeol & Hist Art Res Lab, Oxford OX1 3QJ, England
[4] Univ Surrey, Guildford GU2 7XH, Surrey, England
[5] Inst Geol, DK-1350 Copenhagen, Denmark
关键词
lead isotope analysis; silver; copper; MC-ICPMS; TIMS; laser ablation;
D O I
10.1111/j.1475-4754.2006.00242.x
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
Lead isotope ratios in archaeological silver and copper were determined by MC-ICPMS using laser ablation and bulk dissolution without lead purification. Laser ablation results on high-lead metals and bulk solution analyses on all samples agree within error of TIMS data, suggesting that problems from isobaric interferences and/or mass bias variations due to the presence of matrix elements are insignificant. Inaccurate laser ablation analyses on low-lead copper reflect erroneous mass bias corrections from use of a non-matrix matched standard. However, in most cases, silver and copper are analysable for lead isotopes by bulk dissolution or laser ablation MC-ICPMS with simplified sample preparation.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 50 条
  • [31] Isotope ratios of lead in Italian wines by inductively coupled plasma mass spectrometry
    Larcher, R
    Nicolini, G
    Pangrazzi, P
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (20) : 5956 - 5961
  • [32] Measurements of lead isotope ratio in cement by inductively coupled plasma mass spectrometry
    Chen, JM
    Tan, MG
    Lu, WW
    Li, YL
    Zhang, GL
    Li, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 943 - 946
  • [33] Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry
    Zhou, Tao
    Zhao, Motian
    Wang, Jun
    Lu, Hai
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (05) : 717 - 720
  • [34] ISOTOPE RATIO AND ISOTOPE-DILUTION ANALYSIS OF LEAD IN WINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    DEAN, JR
    EBDON, L
    MASSEY, RC
    FOOD ADDITIVES AND CONTAMINANTS, 1990, 7 (01): : 109 - 116
  • [35] OSMIUM ISOTOPE ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    DICKIN, AP
    MCNUTT, RH
    MCANDREW, JI
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) : 337 - 342
  • [36] Precise Measurement of Tellurium Isotope Ratios in Terrestrial Standards Using a Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Murugan, Rajamanickam
    Aono, Tatsuo
    Sahoo, Sarata Kumar
    MOLECULES, 2020, 25 (08):
  • [38] High precision measurement of germanium isotope ratio variations by multiple collector-inductively coupled plasma mass spectrometry
    Galy, A
    Pomiès, C
    Day, JA
    Pokrovsky, OS
    Schott, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (02) : 115 - 119
  • [39] Determination of Uranium Isotope Ratios in Uranium Particles by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Wang Wei
    Li Zhi-Ming
    Xu Jiang
    Zhou Guo-Qing
    Shen Xiao-Pan
    Zhai Li-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (05) : 703 - 708
  • [40] Determination of Zr isotopic ratios in zircons using laser-ablation multiple-collector inductively coupled-plasma mass-spectrometry
    Zhang, Wen
    Wang, Zaicong
    Moynier, Frederic
    Inglis, Edward
    Tian, Shengyu
    Li, Ming
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1800 - 1809