Metal Artifact Reduction in Computed Tomography After Deep Brain Stimulation Electrode Placement Using Iterative Reconstructions

被引:23
|
作者
Aissa, Joel [1 ]
Boos, Johannes [1 ]
Schleich, Christoph [1 ]
Sedlmair, Martin [2 ]
Krzymyk, Karl [2 ]
Kroepil, Patric [1 ]
Antoch, Gerald [1 ]
Thomas, Christoph [1 ]
机构
[1] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Siemens Healthcare GmbH, Comp Tomog, Forchheim, Germany
关键词
algorithms; artifacts; deep brain stimulation; imaging; image quality; DUAL-ENERGY CT; ORTHOPEDIC IMPLANTS; PARKINSONS-DISEASE; IMAGE QUALITY; FOLLOW-UP; ALGORITHM; FEASIBILITY; COMPLICATION; ACCURACY; SOFTWARE;
D O I
10.1097/RLI.0000000000000296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Diagnostic accuracy of intraoperative computed tomography (CT) after deep brain stimulation (DBS) electrode placement is limited due to artifacts induced by the metallic hardware, which can potentially mask intracranial postoperative complications. Different metal artifact reduction (MAR) techniques have been introduced to reduce artifacts from metal hardware in CT. The purpose of this study was to assess the impact of a novel iterative MAR technique on image quality and diagnostic performance in the follow-up of patients with DBS electrode implementation surgery. Materials and Methods: Seventeen patients who had received routine intraoperative CT of the head after implantation of DBS electrodes between March 2015 and June 2015 were retrospectively included. Raw data of all patients were reconstructed with standard weighted filtered back projection (WFBP) and additionally with a novel iterative MAR algorithm. We quantified frequencies of density changes to assess quantitative artifact reduction. For evaluation of qualitative image quality, the visibility of numerous cerebral anatomic landmarks and the detectability of intracranial electrodes were scored according to a 4-point scale. Furthermore, artifact strength overall and adjacent to the electrodes was rated. Results: Our results of quantitative artifact reduction showed that images reconstructed with iterative MAR (iMAR) contained significantly lower metal artifacts (overall low frequency values, 1608.6 +/- 545.5; range, 375.5-3417.2) compared with the WFBP (overall low frequency values, 4487.3 +/- 875.4; range, 2218.3-5783.5) reconstructed images (P < 0.004). Qualitative image analysis showed a significantly improved image quality for iMAR (overall anatomical landmarks, 2.49 +/- 0.15; median, 3; range, 0-3; overall electrode characteristics, 2.35 +/- 0.16; median, 2; range, 0-3; artifact characteristics, 2.16 +/- 0.08; median, 2.5; range, 0-3) compared with WFBP (overall anatomical landmarks, 1.21 +/- 0.64; median, 1; range, 0-3; overall electrode characteristics, 0.74 +/- 0.37; median, 1; range, 0-2; artifact characteristics, 0.51 +/- 0.15; median, 0.5; range, 0-2; P < 0.002). Conclusions: Reconstructions of cranial CT images with the novel iMAR algorithm in patients after DBS implantation allows an efficient reduction of metal artifacts near DBS electrodes compared with WFBP reconstructions. We demonstrated an improvement of quantitative and qualitative image quality of iMAR compared with WFBP in patients with DBS electrodes.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [41] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [42] Pedicle Screw Pseudofracture on Computed Tomography Secondary to Metal Artifact Reduction
    Ge, Shuliang
    Kumar, Naresh
    Hallinan, James Thomas Patrick Decourcy
    DIAGNOSTICS, 2024, 14 (01)
  • [43] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [44] Customized Total Variation Algorithm for Metal Artifact Reduction in Computed Tomography
    Deng, Ziheng
    Zhou, Yufu
    Zhang, Weikang
    Lin, Zefan
    Zhao, Jun
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3479 - 3482
  • [45] A three-pass method for metal artifact reduction in computed tomography
    Schmitt, H.
    Timmer, J.
    Koehler, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2571 - 2571
  • [46] A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: Cadaveric evaluation after cervical pedicle screw placement
    Lee, In Sook
    Kim, Hak Jin
    Choi, Byung Kwan
    Jeong, Yeon Joo
    Lee, Tae Hong
    Moon, Tae-Yong
    Kang, Dong Won
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) : 635 - 641
  • [47] Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography
    Morioka, Yusuke
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 169 - 180
  • [48] Magnetic resonance-based computed tomography metal artifact reduction using Bayesian modelling
    Nielsen, Jonathan Scharff
    Edmund, Jens Morgenthaler
    Van Leemput, Koen
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24):
  • [49] Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information
    Meilinger, Manuel
    Schmidgunst, Christian
    Schuetz, Oliver
    Lang, Elmer W.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (03): : 174 - 182
  • [50] Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography
    Yusuke Morioka
    Katsuhiro Ichikawa
    Hiroki Kawashima
    Physical and Engineering Sciences in Medicine, 2024, 47 : 169 - 180