Technical and dosimetric aspects of iodine-125 seed reimplantation in suboptimal prostate implants

被引:3
|
作者
Marcu, L. G. [1 ,2 ,3 ]
Lawson, J. M. [1 ]
机构
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA 5000, Australia
[2] Univ Oradea, Fac Sci, Dept Phys, Oradea, Romania
[3] Univ Adelaide, Sch Chem & Phys, Adelaide, SA, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2013年 / 86卷 / 1026期
关键词
ESTRO/EAU/EORTC RECOMMENDATIONS; AMERICAN BRACHYTHERAPY; POSTIMPLANT DOSIMETRY; CANCER;
D O I
10.1259/bjr.20130058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Brachytherapy employing iodine-125 seeds is an established treatment for low-risk prostate cancers. Post-implant dosimetry (PID) is an important tool for identifying suboptimal implants. The aim of this work was to improve suboptimal implants by a subsequent iodine-125 seed top-up (reimplantation), based on the PID results. Methods: Of 255 patients treated between 2009 and 2012, 6 were identified as having received suboptimal implants and were scheduled for seed top-up. Needle configurations and the number of top-up seeds were determined based on post-implant CT images as well as a reimplantation treatment plan. An average of 14 seeds per patient were implanted during each top-up. Dosimetric outcome was assessed via target parameters and doses received by organs at risk. Results: All six patients had a successful top-up, with a 67% increase in the mean dose delivered to 90% of the prostate volume and a 40% increase in the volume that receives 100% of the prescribed dose. However, the final dosimetric assessment was based on the same seed activity, as the planning system does not account for the decay of the initially implanted seeds. Although physical dosimetry is not influenced by different seed activities (doses are calculated to infinity), the radiobiological implications might be slightly different from the situation when optimal implantation is achieved with one treatment only. Conclusion: Seed reimplantation in suboptimal prostate implants is feasible and leads to successful clinical outcomes. Advances in knowledge: Suboptimal prostate implants can occur for various reasons. This work shows that seed reimplantation as salvage therapy can lead to an optimal dosimetric outcome with manageable normal tissue effects.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Genitourinary toxicity after permanent iodine-125 seed implantation: The nationwide Japanese prostate cancer outcome study of permanent iodine-125 seed implantation (J-POPS)
    Tanaka, Nobumichi
    Yorozu, Atsunori
    Kikuchi, Takashi
    Higashide, Satoshi
    Kojima, Shinsuke
    Ohashi, Toshio
    Katayama, Norihisa
    Nakamura, Katsumasa
    Saito, Shiro
    Dokiya, Takushi
    Fukushima, Masanori
    BRACHYTHERAPY, 2019, 18 (04) : 484 - 492
  • [22] Physical and technical quality assurance measures in interstitial brachytherapy of the prostate with iodine-125 seeds
    Kaulich, TW
    Lamprecht, U
    Paulsen, F
    Lorenz, J
    Maurer, U
    Loeser, W
    Bichler, KH
    Nüsslin, F
    Bamberg, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 65 - 65
  • [23] Mass Production of Source Core for Iodine-125 Seed
    Lee, Jin Hee
    Park, Ul Jae
    Son, Kwang Jae
    Choi, Kang Hyuk
    Yu, Kook Hyun
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (07): : 2172 - 2174
  • [24] Iodine-125 seed implantation in the treatment of malignant tumors
    Pan Hu
    Jianwen Huang
    Yanling Zhang
    Huanqing Guo
    Guanyu Chen
    Fujun Zhang
    Journal of Interventional Medicine, 2023, 6 (03) : 111 - 115
  • [25] Preparation of the radioactive source core of iodine-125 seed
    He Jiaheng
    Jiang Lin
    Li Xingliang
    Zhong Wenbin
    Wang Jing
    Ma Zongping
    Jian Yuan
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (04) : 231 - 234
  • [26] Seed-less iodine-125 ophthalmic applicator
    Puchalska, I
    Mielcarski, M
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (01) : 15 - 20
  • [27] Effect of anatomic, procedural, and dosimetric variables on urinary retention after permanent iodine-125 prostate brachytherapy
    Elshaikh, MA
    Angermeier, K
    Ulchaker, JC
    Klein, EA
    Chidel, MA
    Mahoney, S
    Wilkinson, DA
    Reddy, CA
    Ciezki, JP
    UROLOGY, 2003, 61 (01) : 152 - 155
  • [28] Preparation of the radioactive source core of iodine-125 seed
    HE Jiaheng JIANG Lin LI Xingliang ZHONG Wenbin WANG Jing MA Zongping JIAN Yuan Institute of Nuclear Physics and Chemistry
    Nuclear Science and Techniques, 2009, 20 (04) : 231 - 234
  • [29] Seed Density as a New Predictive Index of Seed Migration in Brachytherapy for Prostate Cancer Using Iodine-125 Loose Seed
    Yamaguchi, Takahiro
    Matsuo, Masayuki
    Mori, Takayuki
    Noda, Yoshifumi
    Makita, Chiyoko
    Hyodo, Fuminori
    Iinuma, Koji
    Nakano, Masahiro
    Koie, Takuya
    Tanaka, Hidekazu
    CURRENT ONCOLOGY, 2023, 30 (04) : 4060 - 4066
  • [30] Dosimetric consequences of increased seed strength for I-125 prostate implants - Reply
    Sloboda, RS
    RADIOTHERAPY AND ONCOLOGY, 2004, 70 (02) : 210 - 210