Technical and dosimetric aspects of iodine-125 seed reimplantation in suboptimal prostate implants

被引:3
|
作者
Marcu, L. G. [1 ,2 ,3 ]
Lawson, J. M. [1 ]
机构
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA 5000, Australia
[2] Univ Oradea, Fac Sci, Dept Phys, Oradea, Romania
[3] Univ Adelaide, Sch Chem & Phys, Adelaide, SA, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2013年 / 86卷 / 1026期
关键词
ESTRO/EAU/EORTC RECOMMENDATIONS; AMERICAN BRACHYTHERAPY; POSTIMPLANT DOSIMETRY; CANCER;
D O I
10.1259/bjr.20130058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Brachytherapy employing iodine-125 seeds is an established treatment for low-risk prostate cancers. Post-implant dosimetry (PID) is an important tool for identifying suboptimal implants. The aim of this work was to improve suboptimal implants by a subsequent iodine-125 seed top-up (reimplantation), based on the PID results. Methods: Of 255 patients treated between 2009 and 2012, 6 were identified as having received suboptimal implants and were scheduled for seed top-up. Needle configurations and the number of top-up seeds were determined based on post-implant CT images as well as a reimplantation treatment plan. An average of 14 seeds per patient were implanted during each top-up. Dosimetric outcome was assessed via target parameters and doses received by organs at risk. Results: All six patients had a successful top-up, with a 67% increase in the mean dose delivered to 90% of the prostate volume and a 40% increase in the volume that receives 100% of the prescribed dose. However, the final dosimetric assessment was based on the same seed activity, as the planning system does not account for the decay of the initially implanted seeds. Although physical dosimetry is not influenced by different seed activities (doses are calculated to infinity), the radiobiological implications might be slightly different from the situation when optimal implantation is achieved with one treatment only. Conclusion: Seed reimplantation in suboptimal prostate implants is feasible and leads to successful clinical outcomes. Advances in knowledge: Suboptimal prostate implants can occur for various reasons. This work shows that seed reimplantation as salvage therapy can lead to an optimal dosimetric outcome with manageable normal tissue effects.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants
    Liu, X.
    Rahimian, J.
    Goy, B.
    Cosmatos, H.
    Qian, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3333 - 3333
  • [2] Calibration Seed Sampling for Iodine-125 Prostate Brachytherapy
    Crowe, Scott
    Kairn, Tanya
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 459 - 462
  • [3] Iodine-125 seed implants for low risk prostate cancer: Disease control and opportunities for salvage
    Morton, G.
    Loblaw, D. A.
    Choo, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S42 - S42
  • [4] Iodine-125 seed prostate brachytherapy: seed prediction and class solutions
    Lau, Y. G. J.
    Al-Qaisieh, B.
    Wright, G.
    Brearley, E.
    Mason, J.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S334 - S334
  • [5] Imaging of Prostate Brachytherapy Iodine-125 Seed Migration and Embolization
    Nguyen, B.
    Schoenfeldt, B.
    Plumb, M.
    Tollefson, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [6] CORRELATION BETWEEN PRE- AND POSTIMPLANT DOSIMETRY FOR IODINE-125 SEED IMPLANTS FOR LOCALIZED PROSTATE CANCER
    Al-Qaisieh, Bashar
    Witteveen, Thelma
    Carey, Brendan
    Henry, Ann
    Bottomley, David
    Smith, Jonathan
    Franks, Kevin
    Bownes, Peter
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (02): : 626 - 630
  • [7] PSA kinetics after iodine-125 seed implantation in prostate cancer
    Kocher, M
    Bendel, M
    Weise, C
    Haupt, G
    Engelmann, U
    Müller, RP
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 89 - 89
  • [8] Patterns of failure after iodine-125 seed implantation for prostate cancer
    Lamb, David S.
    Greig, Lynne
    Russell, Grant L.
    Nacey, John N.
    Broome, Kim
    Studd, Rod
    Delahunt, Brett
    Iupati, Douglas
    Jain, Mohua
    Rooney, Colin
    Murray, Judy
    Lamb, Peter J.
    Bethwaite, Peter B.
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 68 - 71
  • [9] Permanent planar iodine-125 implants: The dosimetric effect of geometric parameters for idealized source configurations
    Cormack, Robert A.
    Holloway, Caroline L.
    O'Farrell, Desmond
    Devlin, Phillip M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (04): : 1310 - 1315
  • [10] Dosimetric Analysis and Comparison of Cesium-131 and Iodine-125 for Permanent Prostate Brachytherapy
    Cao, J.
    Gressen, E.
    Perera, H.
    Yu, Y.
    MEDICAL PHYSICS, 2008, 35 (06)