Improvement of haemocompatibility of metallic stents by polymer coating

被引:75
|
作者
Lahann, J
Klee, D
Thelen, H
Bienert, H
Vorwerk, D
Höcker, H
机构
[1] Rhein Westfal TH Aachen, Dept Text & Macromol Chem, D-52062 Aachen, Germany
[2] Rhein Westfal TH Aachen, Fac Med, IZKF BIOMAT, D-52062 Aachen, Germany
[3] Rhein Westfal TH Aachen, Fac Med, Dept Radiol Sci, D-52062 Aachen, Germany
关键词
Polymer; Blood Flow; Chemical Vapor Deposition; Metal Surface; Surface Modification;
D O I
10.1023/A:1008939400812
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternative to open heart surgery in treating arterial diseases causing restricted blood flow is the implantation of intracoronary metallic stents. In spite of the advances in implantation and in spite of the excellent mechanical properties of metallic stents, there are still limitations because of the thrombogenicity of the metal. We have, hence, directed our attention to the coating of metallic stents with an ultrathin polymer layer by chemical vapor deposition (CVD) polymerization of 2-chloroparacyclophan. In a second step of surface modification the poly(2-chloroparaxylylene) layer is modified by treatment with a sulfur dioxide plasma in order to obtain a more hydrophilic surface with new functional groups. The results demonstrate the stable polymer coating of the stents and the improvement of haemocompatibility after treatment with sulfur dioxide plasma. Platelet adhesion is decreased from 85% for the metal surface to 20% for the CVD-coated and sulfur-dioxide-plasma treated surface. (C) 1999 Kluwer Academic Publishers.
引用
收藏
页码:443 / 448
页数:6
相关论文
共 50 条
  • [31] Materials for metallic stents
    Hanawa, Takao
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (02) : 73 - 79
  • [32] New biocompatible polymer surface coating for stents results in a low neointimal response
    Bär, FW
    van der Veen, FH
    Benzina, A
    Habets, J
    Koole, LH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 52 (01): : 193 - 198
  • [33] Materials for metallic stents
    Takao Hanawa
    Journal of Artificial Organs, 2009, 12 : 73 - 79
  • [34] Modeling and experimental studies of peeling of polymer coating for biodegradable magnesium alloy stents
    Wu, Wei
    Petrini, Lorenza
    Altomare, Lina
    Farè, Silvia
    Tremamunno, Rosaria
    Yu, Zhentao
    Migliavacca, Francesco
    Wu, Wei, 1600, Science Press (43): : 2877 - 2882
  • [35] Modeling and Experimental Studies of Peeling of Polymer Coating for Biodegradable Magnesium Alloy Stents
    Wei, Wu
    Petrini, Lorenza
    Altomare, Lina
    Fare, Silvia
    Tremamunno, Rosaria
    Yu Zhentao
    Migliavacca, Francesco
    RARE METAL MATERIALS AND ENGINEERING, 2014, 43 (12) : 2877 - 2882
  • [36] Silk Fibroin as a Coating Polymer for Sirolimus-Eluting Magnesium Alloy Stents
    Xu, Wei
    Yagoshi, Kai
    Asakura, Tetsuo
    Sasaki, Makoto
    Niidome, Takuro
    ACS APPLIED BIO MATERIALS, 2020, 3 (01): : 531 - 538
  • [37] Bioactive glass nanopowder and bioglass coating for biocompatibility improvement of metallic implant
    Fathi, M. H.
    Doostmohammadi, A.
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2009, 209 (03) : 1385 - 1391
  • [38] Comparison of haemocompatibility improvement of four polymeric biomaterials by two heparinization techniques
    Michanetzis, GPA
    Katsala, N
    Missirlis, YF
    BIOMATERIALS, 2003, 24 (04) : 677 - 688
  • [39] Nucleation and development of regular microrelief under deformation of polymer with metallic coating
    Volynskii, AL
    Voronina, EE
    Lebedeva, OV
    Yaminskii, IV
    Bazhenov, SL
    Bakeev, NF
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A & SERIYA B, 1999, 41 (10): : 1627 - 1635
  • [40] Polydimethylsiloxane coating on an ionic polymer metallic composite for a tunable focusing mirror
    Tsai, Shih-An
    Wei, Hsiang-Chun
    Su, Guo-Dung J.
    APPLIED OPTICS, 2012, 51 (35) : 8315 - 8323