A method for the inter-calibration of a matrix of sensors

被引:10
|
作者
Donetti, M
Garelli, E
Marchetto, F
Boriano, A
Bourhaleb, F
Cirio, R
Cornelius, I
Giordanengo, S
La Rosa, A
Nastasi, U
Peroni, C
机构
[1] Fdn CNAO, I-20123 Milan, Italy
[2] Ist Nazl Fis Nucl, I-10125 Turin, Italy
[3] ASP, Turin, Italy
[4] Univ Turin, Dipartimento Fis Sperimentale, I-10125 Turin, Italy
[5] Fdn TERA, I-28100 Novara, Italy
[6] AO Giovanni AS, I-10123 Turin, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 03期
关键词
D O I
10.1088/0031-9155/51/3/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a quick and easy method for the calibration of a matrix of sensors. The algorithm is based on a three-step irradiation procedure which relies only on the constancy of the delivered fluence at each step. With this method the gain of each sensor is derived relative to a reference detector. The algorithm has been applied to a matrix of (32 x 32) ionization chambers. After the calibration coefficients have been applied, by comparing the response of the matrix of chambers to a reference detector over a large field, we determined that the fluence measurement of individual chambers is better than 0.7%. The algorithm solves the cumbersome problem of the relative gain calibration of a matrix of a large number of sensors.
引用
收藏
页码:485 / 495
页数:11
相关论文
共 50 条
  • [41] Inter-calibration of SAR data series for offshore wind resource assessment
    Badger, Merete
    Ahsbahs, Tobias
    Maule, Petr
    Karagali, Joanna
    REMOTE SENSING OF ENVIRONMENT, 2019, 232
  • [42] Inter-calibration of medium-resolution grating spectrometers for MOPITT validation
    Tolton, BT
    Yurganov, L
    McKernan, É
    Predoi-Cross, A
    Grechko, E
    OPTICAL SPECTROSCOPIC TECHNIQUES AND INSTRUMENTATION FOR ATMOSPHERIC AND SPACE RESEARCH III, 1999, 3756 : 492 - 499
  • [43] Radiometric Calibration Stability and Inter-calibration of Solar-band Instruments in Orbit Using the Moon
    Stone, Thomas C.
    EARTH OBSERVING SYSTEMS XIII, 2008, 7081
  • [44] Inter-calibration of the CMS barrel electromagnetic calorimeter using π0→γγ decays
    Litvine, Vladimir
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 159 - 160
  • [45] SWRI/LASP Sounding Rocket Inter-Calibration With The Eit Instrument On Board SOHO
    Frédéric Auchère
    Donald M. Hassler
    David C. Slater
    Thomas N. Woods
    Solar Physics, 2001, 202 : 269 - 280
  • [46] Uncertainty Estimates for Imager Reference Inter-Calibration With CLARREO Reflected Solar Spectrometer
    Lukashin, Constantine
    Wielicki, Bruce A.
    Young, David F.
    Thome, Kurt
    Jin, Zhonghai
    Sun, Wenbo
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1425 - 1436
  • [47] Statistical properties of inter-calibration techniques which use empirical distribution functions
    Crosby, DS
    Randou, E
    GOES-8 AND BEYOND, 1996, 2812 : 614 - 617
  • [48] Radiometric Inter-calibration of Microwave Imagers over Homogeneous Warm Scene Targets
    Datta, Saswati
    Jones, W. Linwood
    2018 IEEE 15TH SPECIALIST MEETING ON MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT (MICRORAD), 2018, : 154 - 157
  • [49] GSICS Inter-Calibration of Infrared Channels of Geostationary Imagers Using Metop/IASI
    Hewison, Tim J.
    Wu, Xiangqian
    Yu, Fangfang
    Tahara, Yoshihiko
    Hu, Xiuqing
    Kim, Dohyeong
    Koenig, Marianne
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1160 - 1170
  • [50] SwRI/LASP sounding rocket inter-calibration with the EIT instrument on board SoHO
    Auchère, F
    Hassler, DM
    Slater, D
    Woods, TN
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 351 - 359