Calibrating networks of low-cost air quality sensors

被引:25
|
作者
DeSouza, Priyanka [1 ,2 ]
Kahn, Ralph [3 ]
Stockman, Tehya [4 ,5 ]
Obermann, William [4 ]
Crawford, Ben [6 ]
Wang, An [7 ]
Crooks, James [8 ,9 ]
Li, Jing [10 ]
Kinney, Patrick [11 ]
机构
[1] Univ Colorado, Dept Urban & Reg Planning, Denver, CO 80202 USA
[2] Univ Colorado, CU Populat Ctr, Boulder, CO 80302 USA
[3] NASA, Goddard Space Flight Ctr, Code 916, Greenbelt, MD 20771 USA
[4] Denver Dept Publ Hlth & Environm, Denver, CO 80202 USA
[5] Univ Colorado, Dept Civil Environm & Architectural Engn, Boulder, CO 80309 USA
[6] Univ Colorado, Dept Geog & Environm Sci, Denver, CO 80202 USA
[7] MIT, Senseable City Lab, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[8] Natl Jewish Hlth, Div Biostat & Bioinformat, Denver, CO USA
[9] Univ Colorado, Dept Epidemiol, Anschutz Med Campus, Denver, CO 80202 USA
[10] Univ Denver, Dept Geog & Environm, Denver, CO 80210 USA
[11] Boston Univ, Sch Publ Hlth, Boston, MA 02118 USA
关键词
POLLUTION; MODELS;
D O I
10.5194/amt-15-6309-2022
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Ambient fine particulate matter (PM2.5) pollution is a major health risk. Networks of low-cost sensors (LCS) are increasingly being used to understand local-scale air pollution variation. However, measurements from LCS have uncertainties that can act as a potential barrier to effective decision making. LCS data thus need adequate calibration to obtain good quality PM2.5 estimates. In order to develop calibration factors, one or more LCS are typically co-located with reference monitors for short or long periods of time. A calibration model is then developed that characterizes the relationships between the raw output of the LCS and measurements from the reference monitors. This calibration model is then typically transferred from the co-located sensors to other sensors in the network. Calibration models tend to be evaluated based on their performance only at co-location sites. It is often implicitly assumed that the conditions at the relatively sparse co-location sites are representative of the LCS network overall and that the calibration model developed is not overfitted to the co-location sites. Little work has explicitly evaluated how transferable calibration models developed at co-location sites are to the rest of an LCS network, even after appropriate cross-validation. Further, few studies have evaluated the sensitivity of key LCS use cases, such as hotspot detection, to the calibration model applied. Finally, there has been a dearth of research on how the duration of co-location (short-term or long-term) can impact these results. This paper attempts to fill these gaps using data from a dense network of LCS monitors in Denver deployed through the city's "Love My Air" program. It offers a series of transferability metrics for calibration models that can be used in other LCS networks and some suggestions as to which calibration model would be most useful for achieving different end goals.
引用
下载
收藏
页码:6309 / 6328
页数:20
相关论文
共 50 条
  • [41] Calibration of low-cost NO2 sensors in an urban air quality network
    van Zoest, Vera
    Osei, Frank B.
    Stein, Alfred
    Hoek, Gerard
    ATMOSPHERIC ENVIRONMENT, 2019, 210 : 66 - 75
  • [42] Intelligent Calibration and Virtual Sensing for Integrated Low-Cost Air Quality Sensors
    Zaidan, Martha Arbayani
    Hossein Motlagh, Naser
    Fung, Pak L.
    Lu, David
    Timonen, Hilkka
    Kuula, Joel
    Niemi, Jarkko V.
    Tarkoma, Sasu
    Petaja, Tuukka
    Kulmala, Markku
    Hussein, Tareq
    IEEE SENSORS JOURNAL, 2020, 20 (22) : 13638 - 13652
  • [43] Indoor air quality monitoring and source apportionment using low-cost sensors
    Higgins, Christina
    Kumar, Prashant
    Morawska, Lidia
    ENVIRONMENTAL RESEARCH COMMUNICATIONS, 2024, 6 (01):
  • [44] Low-cost air quality portable sensors and their potential use in respiratory health
    Sese, L.
    Gille, T.
    Pau, G.
    Dessimond, B.
    Uzunhan, Y.
    Bouvry, D.
    Herve, A.
    Didier, M.
    Kort, F.
    Freynet, O.
    Rotenberg, C.
    Jeny, F.
    Khamis, W.
    Hindre, R.
    Maesano, C. N.
    Planes, C.
    Nunes, H.
    Annesi-Maesano, I.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2023, 27 (11) : 803 - +
  • [45] Editorial: Rise of Low-Cost Sensors and Citizen Science in Air Quality Studies
    Oyola, Pedro
    Carbone, Samara
    Timonen, Hilkka
    Torkmahalleh, Mehdi
    Linden, Jenny
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 10
  • [46] Concept Drift Mitigation in Low-Cost Air Quality Monitoring Networks
    D'Elia, Gerardo
    Ferro, Matteo
    Sommella, Paolo
    Ferlito, Sergio
    De Vito, Saverio
    Di Francia, Girolamo
    SENSORS, 2024, 24 (09)
  • [47] Calibrating Low-cost Structured-light 3D Sensors
    Chakib, R.
    Merillou, N.
    Vincent, P. -J.
    Merillou, S.
    26. INTERNATIONAL CONFERENCE IN CENTRAL EUROPE ON COMPUTER GRAPHICS, VISUALIZATION AND COMPUTER VISION (WSCG 2018), 2018, 2801 : 30 - 38
  • [48] Socioeconomic Disparities of Low-Cost Air Quality Sensors in California, 2017-2020
    Sun, Yi
    Mousavi, Amirhosein
    Masri, Shahir
    Wu, Jun
    AMERICAN JOURNAL OF PUBLIC HEALTH, 2022, 112 (03) : 434 - 442
  • [49] Toward a Unified Terminology of Processing Levels for Low-Cost Air-Quality Sensors
    Schneider, Philipp
    Bartonova, Alena
    Castell, Nuria
    Dauge, Franck R.
    Gerboles, Michel
    Hagler, Gayle S. W.
    Huglin, Christoph
    Jones, Roderic L.
    Khan, Sean
    Lewis, Alastair C.
    Mijling, Bas
    Mueller, Michael
    Penza, Michele
    Spinelle, Laurent
    Stacey, Brian
    Vogt, Matthias
    Wesseling, Joost
    Williams, Ronald W.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (15) : 8485 - 8487
  • [50] Machine learning techniques to improve the field performance of low-cost air quality sensors
    Bush, Tony
    Papaioannou, Nick
    Leach, Felix
    Pope, Francis D.
    Singh, Ajit
    Thomas, G. Neil
    Stacey, Brian
    Bartington, Suzanne
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2022, 15 (10) : 3261 - 3278