Reliability of real ear insertion gain in behind-the-ear hearing aids with different coupling systems to the ear canal

被引:8
|
作者
Jespersen, Charlotte Thunberg [1 ]
Moller, Kimi Nina [1 ]
机构
[1] GN ReSound AS, DK-2750 Ballerup, Denmark
关键词
Real ear measurements; reliability; instant fit coupling systems; MODIFIED PRESSURE;
D O I
10.3109/14992027.2012.744105
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The last decade has offered a multitude of instant fit coupling systems to be fitted with behind-the-ear (BTE) hearing aids. The impact of these designs on the reliability of real ear measurements (REMs) has not been reported. The purpose of this study was to obtain REM reliability data for instant fit coupling systems. Design: REM reliability data was obtained for four different instant-fit coupling systems and for standard size 13 tubing and custom earmolds. REMs were performed for all five coupling systems two times and by two examiners. Study sample: Ten normal-hearing individuals (20 ears) served as participants. Results: The REM test-retest reliability is high for the four instant fit coupling systems as well as for the custom earmolds. The REM inter-examiner reliability is high for three of the four instant fit coupling systems. Conclusions: Carrying out REMs with instant fit coupling systems appears to be fundamentally no different than performing REMs with conventional hearing aids. For either, care should be taken in probe tube placement in terms of insertion depth and maintaining the probe tube placement, and other best practices regarding test environment and test setup should be observed.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [31] Improving speech intelligibility using microphones on behind the ear hearing aids
    Hioka, Yusuke
    Kobayashi, Kei
    Niwa, Kenta
    2019 IEEE 21ST INTERNATIONAL WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING (MMSP 2019), 2019,
  • [32] ALLOWING FOR REAL EAR VENTING EFFECTS WHEN SELECTING THE COUPLER GAIN OF HEARING-AIDS
    DILLON, H
    EAR AND HEARING, 1991, 12 (06): : 406 - 416
  • [33] Difference between the Default Telecoil (T-Coil) and Programmed Microphone Frequency Response in Behind-the-Ear (BTE) Hearing Aids
    Putterman, Daniel B.
    Valente, Michael
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2012, 23 (05) : 366 - 378
  • [34] THE IMPORTANCE OF REAL EAR MEASUREMENT TO DETERMINE THE INSERTION GAIN AT HIGHER SPL
    BRUGEL, FJ
    SCHORN, K
    LARYNGO-RHINO-OTOLOGIE, 1993, 72 (06) : 301 - 305
  • [35] The effects of venting on in-the-ear, in-the-canal, and completely-in-the-canal hearing aid shell frequency responses: Real-ear measures
    Stuart, A
    Allen, R
    Downs, CR
    Carpenter, M
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1999, 42 (04): : 804 - 813
  • [36] Does the Receiver Type Used in Receiver-in-Canal Hearing Aids Have an Effect on Real-Ear-to-Coupler Difference and Coupler Response for Flat Insertion Gain Values?
    Bolandi, Masoud
    Nazeri, Ahmad Reza
    Jalilvand, Hamid
    Baghban, Alireza Akbarzadeh
    AUDITORY AND VESTIBULAR RESEARCH, 2024, 33 (04): : 313 - 321
  • [37] MEASURING IN-EAR GAIN OF HEARING-AIDS BY ACOUSTIC REFLEX METHOD
    TONISSON, W
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1975, 18 (01): : 17 - 30
  • [38] Investigations on the physical factors influencing the ear canal occlusion effect caused by hearing aids
    Zurbruegg, T.
    Stirnemannn, A.
    Kuster, M.
    Lissek, H.
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2014, 100 (03) : 527 - 536
  • [39] Anticipating real-ear insertion response using an external auditory canal model
    Taiji, Hidenobu
    Okamoto, Yasuhide
    Kanzaki, Jin
    AURIS NASUS LARYNX, 2022, 49 (03) : 389 - 395
  • [40] In-the-Canal Versus Behind-the-Ear Microphones Improve Spatial Discrimination on the Side of the Head in Bilateral Cochlear Implant Users
    Mantokoudis, Georgios
    Kompis, Martin
    Vischer, Mattheus
    Haeusler, Rudolf
    Caversaccio, Marco
    Senn, Pascal
    OTOLOGY & NEUROTOLOGY, 2011, 32 (01) : 1 - 6